Ibrahim Ismael Alnaib

Dr. Ibrahim Ismael Alnaib

orcid
Assistant Professor, Doctor

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
SKSa’aD Ahmed S. Al Kazzaz
Sa’aD Ahmed S. Al Kazzaz
Ibrahim Ismael AlnaibIbrahim Ismael Alnaib
Ibrahim Ismael Alnaib
KMKaram Khairullah Mohammed
Karam Khairullah Mohammed
The aim of this paper is to design a three-phase distance relay using an adaptive neuro-fuzzy inference system algorithm (ANFIS). The proposed relay is used to protect the power transmission lines where they are subjected to faults continuously. These faults may produce a high electric current which leads to high damage in power system equipment. The relay is used to detect the transmission line faults by measuring the voltage and current values for each phase. The line impedance is then calculated to detect the faults and issue instantaneous trip signal to circuit breaker, to separate the fault zone of the transmission line without affecting the work of other relays. To isolate the faulty line without affecting the other lines within the network the relays were trained using adaptive neuro-fuzzy inference system (ANFIS). The obtained results through this work show that the designated distance relay with (ANFIS) algorithm has the ability to detect the faults occurrence, recognize it from the cases of the disturbance and to isolate only the fault zone without affecting the work of other relays in system.

2 January 2025 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
Ibrahim Ismael AlnaibIbrahim Ismael Alnaib
Ibrahim Ismael Alnaib
Ahmed Nasser B. AlsammakAhmed Nasser B. Alsammak
Ahmed Nasser B. Alsammak
Introduction. Induction Motors (IM) possess advantages such as stability, reliability, and ease of control, making them suitable for many purposes; the literature elucidates control methodologies for IM drives, primarily focusing on scalar and vector control techniques; the conventional method utilized in manufacturing is scalar control, which unfortunately demonstrates optimal performance solely in steady-state conditions. The absence of significant instantaneous torque control restricts flux and dissociated torque, resulting in subpar dynamic responsiveness. Indirect Field Oriented Control (IFOC) for IM drives has proven beneficial for various industrial applications, particularly electric vehicle propulsion. The primary advantages of this approach include the decoupling of torque and flux characteristics and its straightforward implementation. The novelty of the work consists of a proposal for a driving cycle model for testing the control system of electric vehicles in Mosul City (Iraq), and using a Complex Fractional Order Proportional Integral (CFOPI) controller to control IMs via IFOC strategies, the Artificial Bee Colony (ABC) algorithm was applied, which is considered to be highly efficient in finding the values of controllers. Purpose. Improvement IFOC techniques for the regulation of IM speed. Methods. Using the ABC algorithm in tuning the two unique CFOPI controller, and a Real Fractional Order Proportional Integral (RFOPI) controller, to regulate the speed of a three-phase IM via IFOC techniques. Results. The CFOPI controller outperforms the RFOPI controller in obtaining the best performance in controlling the IM. Practical value. The CFOPI controller demonstrates superiority over the RFOPI controller, as evidenced by the lower integral time absolute error in motor speed tracking during the driving cycle 2.1004 for the CFOPI controller compared to 2.1538 for the RFOPI controller. References 27, tables 5, figures 4.

1 April 2023 in Bulletin of Electrical Engineering and Informatics
Verified
Journal Article
Open access
PDF file
AAAli Abbawi Mohammed Alabbawi
Ali Abbawi Mohammed Alabbawi
Ibrahim Ismael AlnaibIbrahim Ismael Alnaib
Ibrahim Ismael Alnaib
OAOmar Alyozbaky
Omar Alyozbaky
KMKaram Khairullah Mohammed
Karam Khairullah Mohammed
This study proposes an intelligent protection relay design that uses artificial neural networks to secure electrical parts in power infrastructure from different faults. Electrical transformer and transmission lines are protected using intelligent differential and distance relay, respectively. Faults are categorized, and their locations are pinpointed using three-phase current values and zero-current characteristics to differentiate between non-earth and ground faults. The optimal aspects of the artificial neural network were chosen for optimal results with the least possible error. Levenberg-Marquardt was established as the ideal training technique for the suggested system comprising the differential relay. Levenberg-Marquardt was the optimal training technique for the proposed framework consisting of the differential relay. Fault detection and categorization were performed using 20 and 50 hidden layers, and the corresponding error rates were 9.9873e-3 and 1.1953e-29. In the context of fault detection by the distance relay, the hidden layer neuron counts were 400, 250, and 300 for fault detection, categorization, and location; training error rates were 7.8761e-2, 1.2063e-6, and 1.1616e-26, respectively.

1 April 2020
Verified
Conference Paper
Closed access
AAAli Abbawi
Ali Abbawi
Ibrahim Ismael AlnaibIbrahim Ismael Alnaib
Ibrahim Ismael Alnaib
OAOmar Alyozbaky
Omar Alyozbaky
Kinds of faults that happened at the same time in different areas of the network, called simultaneous faults. Both parallel and open types of faults can be occurring. There are often simultaneous faults of interest in a power system that is combined with all types of faults. Two different types of fault can consist of simultaneous faults at the same location or at different locations. Numerous investigations have studied the power transmission line fault detection and classification. In this paper, we have presents simultaneous faults when it is happening in the power system networks. Two methods have been used to compare the results. The two-port method showed it is more than accuracy from the traditional method. The IEEE 14-bus has been chosen to do this comparator. The values of the voltage buses, angles, and power consumed were present respectively.

2 March 2025 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
Ibrahim Ismael AlnaibIbrahim Ismael Alnaib
Ibrahim Ismael Alnaib
Ahmed Nasser B. AlsammakAhmed Nasser B. Alsammak
Ahmed Nasser B. Alsammak
KMK. K. Mohammed
K. K. Mohammed
Introduction. Brushless DC (BLDC) motor is a type of permanent magnet synchronous motor that operates without brushes employed in many applications owing to its efficiency and control in electric cars. One of the main reasons BLDC motors are better than brushed DC motors is that they employ an electronic commutation circuit instead of a mechanical one. The fractional order sliding mode controller (FOSMC) was used, which is characterized by high durability and is not affected by the disturbances that the motor is exposed to during operation, as well as overcoming the chattering phenomenon present in the conventional sliding mode controller (CSMC). The novelty of the proposed work consists of to use FOSMC by genetic algorithm (GA) to mitigate the chattering phenomena in sliding mode control (SMC) for optimal response for speed control and regeneration braking control in BLDC motor by using single stage by voltage source inverter and decrease energy use during motor starting. Purpose. Improvement FOSMC techniques for the regulation of BLDC motor’s driving control system. Methods. Employing the GA to optimize the parameters of FOSMC to mitigate the chattering phenomenon in SMC to regulate BLDC motor’s driving control system. Results. A comparison was made between two types of sliding controllers to obtain the best performance of the control system in speed control operations and motor braking operations, the FOSMC, through parameter optimization via the GA, surpasses the CSMC in achieving optimal performance in driving the BLDC motor. Practical value. FOSMC exhibits superiority over the CSMC, as indicated by the reduced integral time absolute error in motor speed tracking and regenerative brake control, with values of (0.028, 0.046, and 0.075) for the FOSMC, in contrast to (2.72, 1.56, and 0.17) for the CSMC, the overshoot for FOSMC is (0, 0, and 11.4), but for CSMC it is (60.4, 43.7, and 11.2). During braking mode for FOSMC, the power recovery from the motor to the battery was (1.96, 9, and 17.76), but in CSMC, it was (0.99, 4.49, and 11.98). Moreover, the braking length was expedited, and the battery’s initial power consumption diminished at the outset. References 32, tables 5, figures 6.