This paper presents the results of new hexagonal configuration at the T-joint of three-phase transformer core. The proposed model is compared with previous T-joint design, Butt-lap, which is widely used at present by many transformer manufacturers. The magnetic flux density distribution and core loss of a transformer rated 1000kVA are analyzed for the two types of T-joint design. The 3D simulation are carried out by using the ANSYS-Maxwell software. The results show that the magnetic flux density of the hexagonal shape T-joint is well distributed compared to that in the Butt-lap T-joint design. The core loss for the proposed model (hexagon) T-joint indicates a reduction of more than 11 % compared to the Butt-lap T-joint design.
1 June 2023 in International Journal of Electrical and Computer Engineering (IJECE)
Recently, the demand for electric vehicles (EV) has been on the rise in global markets due to the orientation of national policies to reduce emissions and global warming through the electrification of the transportation sector and the use of clean energy sources. Electric vehicles function on batteries, which must be recharged, either by slow charging at home or by fast charging with a direct current. In the fast-charging process, the batteries can be charged in less than 15 minutes. In this paper, an off-board charger with a three-phase, six-pulse voltage rectifier was designed using the MATLAB/Simulink program. The closed control circuit was simulated, where the simulation results were influenced by changes to the input voltage. When the input voltage was increased or decreased by 5%, this control maintained the value of the current and voltage at the output to be equal to the reference values required to achieve fast charging. The simulation results showed that in the first case where no filter was used, the output voltage and current had a high amount of ripple that exceeded the permissible value. Therefore, a low-pass filter was designed to reduce the ripple factor to a value that was within the permissible limit.
1 April 2023 in Bulletin of Electrical Engineering and Informatics
This study proposes an intelligent protection relay design that uses artificial neural networks to secure electrical parts in power infrastructure from different faults. Electrical transformer and transmission lines are protected using intelligent differential and distance relay, respectively. Faults are categorized, and their locations are pinpointed using three-phase current values and zero-current characteristics to differentiate between non-earth and ground faults. The optimal aspects of the artificial neural network were chosen for optimal results with the least possible error. Levenberg-Marquardt was established as the ideal training technique for the suggested system comprising the differential relay. Levenberg-Marquardt was the optimal training technique for the proposed framework consisting of the differential relay. Fault detection and categorization were performed using 20 and 50 hidden layers, and the corresponding error rates were 9.9873e-3 and 1.1953e-29. In the context of fault detection by the distance relay, the hidden layer neuron counts were 400, 250, and 300 for fault detection, categorization, and location; training error rates were 7.8761e-2, 1.2063e-6, and 1.1616e-26, respectively.
Kinds of faults that happened at the same time in different areas of the network, called simultaneous faults. Both parallel and open types of faults can be occurring. There are often simultaneous faults of interest in a power system that is combined with all types of faults. Two different types of fault can consist of simultaneous faults at the same location or at different locations. Numerous investigations have studied the power transmission line fault detection and classification. In this paper, we have presents simultaneous faults when it is happening in the power system networks. Two methods have been used to compare the results. The two-port method showed it is more than accuracy from the traditional method. The IEEE 14-bus has been chosen to do this comparator. The values of the voltage buses, angles, and power consumed were present respectively.
1 June 2023 in International Journal of Power Electronics and Drive Systems (IJPEDS)
The rising electricity consumption, rapid fossil fuel depletion, and a higher shift to the use of renewable or green energy resources have increased the need to integrate renewable and distributed energy resources (DERs), like solar photovoltaic (PV) energy to power the utility grids. In this study, the researchers have determined the effect of PV inverters to offer reactive power to an adapted IEEE 13-node distribution network. Power flow analyses were conducted on MATLAB/Simulink for various reactive power modes of PV inverters to show the effect of the reactive power on the regulation of grid voltage, reduced the total harmonic distortion (THD), and maintain the power factor so as to improve the ability of the system to handle power. The result shows that using a 400 KW PV system in a bus (675) led to a reduction in the power generated from the generator by 11%, and the use of the reactive power capability of PV inverters on-site improved the voltage profile significantly. as well, reduced the voltage THD by 27.09% when injected with reactive power, reduce the current THD by 77.39% When absorbing reactive power, and improved the power factor on-site.