Ahed Imtirat

Dr. Ahed Imtirat

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
AKAssaf Kratz
Assaf Kratz
RYRonit Yagev
Ronit Yagev
ABAvner Belkin
Avner Belkin
MGMordechai Goldberg
Mordechai Goldberg
AZAlon Zahavi
Alon Zahavi
AIAhed Imtirat
Ahed Imtirat
Objectives: The objective of this study was to evaluate the agreement and clinical interchangeability of intraocular pressure (IOP) measurements obtained with the mechanical Haag-Streit AT900 Goldmann applanation tonometer (mGAT) and the digital Huvitz HT5000 applanation tonometer (dGAT). Methods: This retrospective comparative study included 53 eyes of 28 patients undergoing routine ophthalmologic evaluation. Each eye underwent IOP measurement using both mGAT and dGAT in a randomized sequence. Central corneal thickness (CCT) was also recorded. Pearson’s correlation coefficient was used to determine correlation between paired IOP measurements. Bland–Altman plots were graphed for the analysis of differences for IOP between the instruments. Results: A total of 53 eyes of 28 patients (15 males) were included in the study. The mean age of the patients was 62.6 years. The mean mGAT and dGAT measurements were 16.3 ± 6.6 mmHg (range 9–50) and 16.4 ± 6.2 mmHg (range 8.8–45.9), respectively (p = 0.53). A strong, significant positive correlation was found for paired IOP measurements by the two instruments (r = 0.98; p < 0.0001). Bland–Altman analysis revealed 95% limits of agreement from −2.5 to +2.3 mmHg, with a small but statistically significant proportional bias favoring mGAT at higher IOP levels. Additionally, 91% of paired measurements were within ±2 mmHg. CCT-related differences were statistically and clinically insignificant. Conclusions: IOP measurements obtained with mGAT and dGAT were highly correlated and clinically interchangeable for the range tested. The Huvitz HT5000 may serve as a reliable alternative to the classic Goldmann tonometer in routine clinical settings.

25 April 2025 in Journal of Glaucoma
Verified
Journal Article
Closed access
ETElizabeth Tal-Mushinski
Elizabeth Tal-Mushinski
AIAhed Imtirat
Ahed Imtirat
TKTomer Bsc Kerman
Tomer Bsc Kerman
IYItamar Bsc Yariv
Itamar Bsc Yariv
ODOmer Bsc Dor
Omer Bsc Dor
ETErez Tsumi
Erez Tsumi
Précis: Ahmed glaucoma valve (AGV) emerges as a more effective primary procedure compared with trabeculotomy for pediatric glaucoma patients, especially within the first 2 years. Purpose: To compare the outcomes between initial AGV implantation and trabeculotomy in children with primary congenital glaucoma (PCG). Patients and Methods: This retrospective cohort study was conducted on patients with PCG who underwent either trabeculotomy or AGV implantation between 1998 and 2022 at Soroka University Medical Center. Outcome measures included intraocular pressure (IOP) change, cup-to-disc ratio, corneal clarity, additional surgeries, ocular hypotensive medication use, and the occurrence of adverse events over 36 months of follow-up. Primary success was defined as a postoperative IOP of 5–21 mmHg without additional surgeries or serious sight-threatening complications. Results: A total of 83 eyes from 55 patients were included: 34 in the AGV group and 49 in the trabeculotomy group. The primary success rate was significantly higher at all time points of the follow-up period in the AGV group compared with the trabeculotomy group (P=0.014). Trabeculotomy was associated with a significantly higher risk of surgical failure compared with AGV implantation (HR: 3.23; 95% CI: 1.35–7.71; P=0.008). Notably, only 2 eyes in the AGV group underwent additional surgeries, compared with 25 in the trabeculotomy group (P<0.001). Conclusions: AGV as an initial procedure seems to be safe and more effective than trabeculotomy for the treatment of PCG in this select population, with fewer additional surgeries.

Verified
Journal Article
Open access
PDF file
LSLara Saaida
Lara Saaida
ESEilon Shany
Eilon Shany
AIAhed Imtirat
Ahed Imtirat
NBNitzan Burrack
Nitzan Burrack
VNVictor Novack
Victor Novack
TETamar Eshkoli
Tamar Eshkoli
Background/Objectives: We aimed to evaluate the association between diabetes mellitus (DM) during pregnancy and retinopathy of prematurity (ROP) in preterm infants younger than 32 gestational weeks or infants with low birthweight (<1500 g). Methods: We conducted a retrospective nested case–control study of all premature infants who were born alive and survived the post-delivery hospitalization period in Soroka Medical Center, with either gestational age younger than 32 weeks or birthweight less than 1500 g, during the years 2013–2021. The infants were divided into two groups according to ROP status. Multivariable Generalized Estimating Equations (GEE) were used to analyze the association between ROP and DM, adjusting for potential confounders, including maternal age, diabetes type (GDM vs. pre-gestational DM), gestational age, birthweight (<1250 g), duration of oxygen supplementation, antenatal corticosteroid courses, and birth plurality. Results: During the study period, there were 881 pairs of women and newborns who met the inclusion criteria. The ROP group included 345 infants (39.1%). Twenty-two (6.4%) of the mothers in the ROP group were diagnosed with DM during pregnancy compared with 52 of 536 (9.7%) in the control group (p = 0.082). ROP was associated with oxygen treatment (OR 1.05; 95% CI, 1.03–1.08; p < 0.001), birthweight < 1250 g (OR 2.70; 95% CI, 1.93–3.78; p < 0.001) and advanced maternal age (OR 1.04; 95% CI, 1.01–1.06; p = 0.006). Prenatal steroid treatment was identified as a significant protective factor against ROP (OR 0.73; 95% CI, 0.60–0.89; p = 0.002). No statistically significant association was observed between maternal DM and ROP (OR 0.62; 95% CI 0.34–1.13; p = 0.12). These findings should be interpreted cautiously given the retrospective design and the limited availability of glycemic control data. Conclusions: Maternal diabetes mellitus was not significantly associated with the risk of ROP in this cohort.

1 April 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
DGDana Garzozi
Dana Garzozi
MCMoshe Carmel
Moshe Carmel
GNGil Neuman
Gil Neuman
ALAnna Lisitsky
Anna Lisitsky
ZBZohar Bracha
Zohar Bracha
MGMordechai Goldberg
Mordechai Goldberg
Background/Objectives: To evaluate the short-term effects of direct selective laser trabeculoplasty (DSLT) on retinal nerve fiber layer (RNFL) and ganglion cell layer (GCL) thickness in patients with ocular hypertension (OHT) and primary open-angle glaucoma (POAG). Methods: This retrospective, single-center study included 45 eyes of 45 patients with OHT or POAG who underwent DSLT at Shaare Zedek Medical Center between February 2024 and February 2025. The primary outcome was the change in RNFL and GCL thickness, as measured by spectral-domain optical coherence tomography (SD-OCT) before and two months after treatment. Secondary outcomes included intraocular pressure (IOP) reduction, corrected distance visual acuity (CDVA), and safety. Only high-quality OCT scans (quality score > 25) were included in the analysis. Results: OCT analysis revealed no statistically significant changes in the inner retinal structure two months post-treatment. The mean RNFL thickness was 77.1 ± 17.2 µm at baseline and 77.4 ± 17.3 µm at follow-up (p = 0.285). The mean GCL thickness remained unchanged (42.4 ± 11.6 µm vs. 42.4 ± 11.3 µm, p = 0.750). CDVA remained stable (0.2 ± 0.4 vs. 0.2 ± 0.4 logMAR; p = 0.351), and no vision-threatening complications were observed. Mean IOP decreased significantly from 19.7 ± 4.0 mmHg at baseline to 16.2 ± 3.5 mmHg at two months (p < 0.001). The mean total laser energy delivered was 196.5 ± 10.2 mJ (range: 176–210 mJ). Conclusions: DSLT was not associated with significant short-term changes in RNFL or GCL thickness, supporting its structural safety in patients with OHT or glaucoma. Further long-term studies are warranted to determine the durability of these findings and the potential neuroprotective effects of DSLT.