Jin Kwan Hong

Prof. Jin Kwan Hong

Gachon University, Department of HVAC System and Fire Protection Engineering
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
MSMinki Sung
Minki Sung
SJSeongmin Jo
Seongmin Jo
SLSang Eun Lee
Sang Eun Lee
MKMoran Ki
Moran Ki
BCBo Youl Choi
Bo Youl Choi
JHJin Kwan Hong
Jin Kwan Hong
In this study, the results of an airflow investigation conducted on 7 June 2015 as part of a series of epidemiologic investigations at Pyeongtaek St. Mary’s Hospital, South Korea, were investigated. The study involved 38 individuals who were infected directly and indirectly with Middle East Respiratory Syndrome (MERS), by a super-spreader patient. Tracer gas experiments conducted on the eighth floor, where the initial patient was hospitalized, confirmed that the tracer gas spread to adjacent patient rooms and rooms across corridors. In particular, the experiment with an external wind direction and speed similar to those during the hospitalization of the initial patient revealed that the air change rate was 17–20 air changes per hour (ACH), with air introduced through the window in the room of the infected patient (room 8104). The tracer gas concentration of room 8110, which was the farthest room, was 7.56% of room 8104, indicating that a high concentration of gas has spread from room 8104 to rooms across the corridor. In contrast, the tracer gas was barely detected in a maternity ward to the south of room 8104, where there was no secondary infected patient. Moreover, MERS is known to spread mainly by droplets through close contact, but long-distance dispersion is probable in certain environments, such as that of a super-spreader patient hospitalized in a room without ventilation, hospitals with a central corridor type, and indoor airflow dispersion due to external wind.

13 March 2019 in Royal Society Open Science
Verified
Journal Article
Open access
SJSeongmin Jo
Seongmin Jo
JHJin Kwan Hong
Jin Kwan Hong
SLSang-Eun Lee
Sang-Eun Lee
MKMoran Ki
Moran Ki
BCBo Youl Choi
Bo Youl Choi
MSMinki Sung
Minki Sung
Middle East respiratory syndrome (MERS) is known to be transmitted through close contact. However, epidemiological surveys of MERS in Korea indicated that some secondary patients were infected without close contact. Therefore, the possibility of other transmission routes must be identified. In this study, the possibility of MERS spreading through airflow was investigated on the eighth floor of Pyeongtaek St Mary's Hospital. Computational fluid dynamics was used to analyse the indoor airflow and passive tracer diffusion during the index patient's stay. Six cases were simulated for different outdoor wind directions and indoor mechanical ventilation operations. When a passive tracer was released in ward 8104, where the index patient was hospitalized, the passive tracer spread through the indoor airflow, which was created by the outdoor airflow. Ward 8109, which had the largest number of infected cases and was far distant from ward 8104, showed passive tracer concentration in all cases. This result indicates that MERS may have spread through airflow. The study results do not imply that the infection pathway of MERS is airborne. However, the results show the possibility of MERS spreading through airflow in specific environments such as poor ventilation environments.

MJMinji Jung
Minji Jung
WCWoong June Chung
Woong June Chung
MSMinki Sung
Minki Sung
SJSeongmin Jo
Seongmin Jo
JHJin Kwan Hong
Jin Kwan Hong
Identifying infection transmission routes in hospitals may prevent the spread of respiratory viruses and mass infections. Most previous related research focused on the air movement of passive tracers, which typically represent breathing. In this study, particle evaporation and dispersions with various particle sizes were applied to evaluate particle movement because of breathing and coughing using computational fluid dynamics (CFD) simulations. Pyeongtaek St. Mary Hospital, where a Middle East respiratory syndrome (MERS) index patient infected several patients on the same floor, was used for a case study. We compared the dispersion characteristics of various particle sizes and validated results by comparing infection rates in different ward. Results indicated that droplets spread across the corridor and dispersed to wards that were more than 17 m apart from the index patient by natural ventilation. Droplets from exhaled breath under steady-state simulation showed a wider range of dispersion than cough droplets under transient simulation, but cough droplet dispersion was more consistent with the actual infection rate in each ward. Cough droplets sized under 75 µm evaporated to 26% of the initial size and started to disperse into the corridor within one minute; in nine minutes, droplets dispersed throughout every ward. This study may increase awareness on the dispersion characteristics of infectious particles.

1 January 2023 in Journal of Korean Medical Science
Verified
Journal Article
Open access
PDF file
SHSu Ha Han
Su Ha Han
MJMinji Jung
Minji Jung
HJHeon-Jae Jeong
Heon-Jae Jeong
JHJin Kwan Hong
Jin Kwan Hong
Han SH, et al. J Korean Med Sci. 2023 Aug;38(34):e290. https://doi.org/10.3346/jkms.2023.38.e290