Woong June Chung

Dr. Woong June Chung

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2014 in Energy and Buildings
Verified
Journal Article
Closed access
SPSang Hoon Park
Sang Hoon Park
WCWoong June Chung
Woong June Chung
MYMyoung Souk Yeo
Myoung Souk Yeo
KKKwang Woo Kim
Kwang Woo Kim

1 November 2019 in Energy Policy
Verified
Journal Article
Open access
CHCaroline Hughes
Caroline Hughes
SNSukumar Natarajan
Sukumar Natarajan
CLChunde Liu
Chunde Liu
WCWoong June Chung
Woong June Chung
MHManuel Herrera
Manuel Herrera


11 April 2017 in Sustainability
Verified
Journal Article
Open access
PDF file
WCWoong June Chung
Woong June Chung
SPSanghoon Park
Sanghoon Park
Myoung Souk YeoMyoung Souk Yeo
Myoung Souk Yeo
KKKwang Woo Kim
Kwang Woo Kim
The objectives of this study were to investigate the thermally activated building system (TABS) mechanism for appropriate use of the system and to apply the proper concept of TABS for each zone by using different TABS control strategies. In order to examine the TABS mechanism, dynamic simulation with EnergyPlus was used to model the office building with TABS, because the radiant heat exchange characteristics of the TABS according to the time variable was critical. The typical control concept of TABS, self-regulation, was applied in the simulation by setting the supply water temperature as room setpoint temperature. As a result, the advantage of self-regulation can be amplified by utilizing the entire thermal mass of the TABS, which can be executed by customizing to target a specific type of load. Since the large area of the office building may comprise different loads in different zones, the TABS control according to the different zone loads were proposed. By separating the control strategy from zone to zone, the proposed control strategy improved the thermal comfort by 5%, reduced peak heating load by 10%, reduced cooling load by 36%, and decrease the total energy consumption by 13%. This study demonstrated a possible improvement on self-regulation of TABS with separate zone controls.

1 June 2020 in Energy for Sustainable Development
Verified
Journal Article
Closed access
LNL.O. Neves
L.O. Neves
AHA.P. Hopes
A.P. Hopes
WCWoong June Chung
Woong June Chung
SNS. Natarajan
S. Natarajan

MJMinji Jung
Minji Jung
WCWoong June Chung
Woong June Chung
MSMinki Sung
Minki Sung
SJSeongmin Jo
Seongmin Jo
JHJin Kwan Hong
Jin Kwan Hong
Identifying infection transmission routes in hospitals may prevent the spread of respiratory viruses and mass infections. Most previous related research focused on the air movement of passive tracers, which typically represent breathing. In this study, particle evaporation and dispersions with various particle sizes were applied to evaluate particle movement because of breathing and coughing using computational fluid dynamics (CFD) simulations. Pyeongtaek St. Mary Hospital, where a Middle East respiratory syndrome (MERS) index patient infected several patients on the same floor, was used for a case study. We compared the dispersion characteristics of various particle sizes and validated results by comparing infection rates in different ward. Results indicated that droplets spread across the corridor and dispersed to wards that were more than 17 m apart from the index patient by natural ventilation. Droplets from exhaled breath under steady-state simulation showed a wider range of dispersion than cough droplets under transient simulation, but cough droplet dispersion was more consistent with the actual infection rate in each ward. Cough droplets sized under 75 µm evaporated to 26% of the initial size and started to disperse into the corridor within one minute; in nine minutes, droplets dispersed throughout every ward. This study may increase awareness on the dispersion characteristics of infectious particles.