Jerzy Krzysztof Wranicz

Prof. Jerzy Krzysztof Wranicz

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2022 in Nature Medicine
Verified
Journal Article
Open access
PDF file
AVAdriaan A. Voors
Adriaan A. Voors
CAChristiane E. Angermann
Christiane E. Angermann
JTJohn R. Teerlink
John R. Teerlink
SCSean P. Collins
Sean P. Collins
MKMikhail Kosiborod
Mikhail Kosiborod
PPPiotr Ponikowski
Piotr Ponikowski
The sodium–glucose cotransporter 2 inhibitor empagliflozin reduces the risk of cardiovascular death or heart failure hospitalization in patients with chronic heart failure, but whether empagliflozin also improves clinical outcomes when initiated in patients who are hospitalized for acute heart failure is unknown. In this double-blind trial (EMPULSE; NCT04157751), 530 patients with a primary diagnosis of acute de novo or decompensated chronic heart failure regardless of left ventricular ejection fraction were randomly assigned to receive empagliflozin 10 mg once daily or placebo. Patients were randomized in-hospital when clinically stable (median time from hospital admission to randomization, 3 days) and were treated for up to 90 days. The primary outcome of the trial was clinical benefit, defined as a hierarchical composite of death from any cause, number of heart failure events and time to first heart failure event, or a 5 point or greater difference in change from baseline in the Kansas City Cardiomyopathy Questionnaire Total Symptom Score at 90 days, as assessed using a win ratio. More patients treated with empagliflozin had clinical benefit compared with placebo (stratified win ratio, 1.36; 95% confidence interval, 1.09–1.68; P = 0.0054), meeting the primary endpoint. Clinical benefit was observed for both acute de novo and decompensated chronic heart failure and was observed regardless of ejection fraction or the presence or absence of diabetes. Empagliflozin was well tolerated; serious adverse events were reported in 32.3% and 43.6% of the empagliflozin- and placebo-treated patients, respectively. These findings indicate that initiation of empagliflozin in patients hospitalized for acute heart failure is well tolerated and results in significant clinical benefit in the 90 days after starting treatment.

18 November 2024 in JACC
Verified
Journal Article
Open access
MKMikhail N. Kosiborod
Mikhail N. Kosiborod
DCDavid Z.I. Cherney
David Z.I. Cherney
ADAkshay S. Desai
Akshay S. Desai
JTJeffrey M. Testani
Jeffrey M. Testani
SVSubodh Verma
Subodh Verma
MPMark C. Petrie
Mark C. Petrie
Mineralocorticoid receptor antagonists (MRA) improve outcomes in patients with heart failure and reduced ejection fraction (HFrEF) but are underused in clinical practice. Observational data suggest that hyperkalemia is the leading obstacle for the suboptimal use of MRA. We evaluated the effects of sodium zirconium cyclosilicate (SZC) in optimizing use of spironolactone among participants with HFrEF and hyperkalemia. REALIZE-K (NCT04676646) was a prospective, double-blind, randomized- withdrawal trial in participants with HFrEF (NYHA II-IV; left ventricular ejection fraction ≤40%), optimal guideline-directed therapy (except MRA), and prevalent or incident MRA- induced hyperkalemia. During open-label run-in, participants underwent spironolactone titration (target: 50 mg/daily); those with hyperkalemia started SZC. Participants with normokalemia (potassium 3.5-5.0 mEq/L) on SZC and spironolactone ≥25 mg/daily were randomized to continued SZC or placebo for 6 months. The primary endpoint was optimal treatment response (normokalemia on spironolactone ≥25 mg/daily without rescue therapy for hyperkalemia [months 1-6]). The five key secondary endpoints were tested hierarchically. Exploratory endpoints included a composite of adjudicated cardiovascular death or worsening HF events (hospitalizations and urgent visits). Overall, 203 participants were randomized (SZC 102, placebo 101). Higher percentage of SZC- versus placebo-treated participants had optimal response (71% vs 36%; OR 4.45 [95% CI 2.89-6.86]; p<0.001). SZC (versus placebo) improved the first four key secondary endpoints: normokalemia on randomization dose of spironolactone and without rescue therapy (58% vs 23%; OR 4.58 [2.78-7.55]; p<0.001), receiving spironolactone ≥25 mg/daily (81% vs 50%; OR 4.33 [2.50-7.52]; p<0.001), time to hyperkalemia (HR 0.51 [0.37-0.71]; p<0.001), time to decrease/discontinuation of spironolactone due to hyperkalemia (HR 0.37 [0.17-0.73]; p=0.006). There was no between-group difference in KCCQ-CSS at 6 months (-1.01 points [-6.64-4.63]; p=0.72). Adverse events (64% vs 63%) and serious adverse events (23% vs 22%) were balanced between SZC and placebo, respectively. Composite of CV death or worsening HF occurred in 11 (11%) participants in the SZC group (1 with CV death, 10 with HF events) and 3 (3%) participants in the placebo group (1 with CV death, 2 with HF events; log-rank nominal p=0.034). In participants with HFrEF and hyperkalemia, SZC led to large improvements in the percentage of participants with normokalemia while on optimal spironolactone dose, and reduced risk of hyperkalaemia and down-titration/discontinuation of spironolactone. Although underpowered for clinical outcomes, more participants had HF events with SZC than placebo, which should be factored into the clinical decision making.

2 July 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
BMBéla Merkely
Béla Merkely
RHRobert HATALA
Robert HATALA
EMEperke Merkel
Eperke Merkel
MSMátyás Szigeti
Mátyás Szigeti
BVB Veres
B Veres
Annamária KosztinAnnamária Kosztin
Annamária Kosztin
Recommendations on cardiac resynchronization therapy (CRT) in patients with atrial fibrillation or flutter (AF) are based on less robust evidence than those in sinus rhythm (SR). We aimed to assess the efficacy of CRT upgrade in the BUDAPEST-CRT Upgrade trial population by their baseline rhythm. Heart failure patients with reduced ejection fraction (HFrEF) and previously implanted pacemaker (PM) or implantable cardioverter defibrillator (ICD) and ≥20% right ventricular (RV) pacing burden were randomized to CRT with defibrillator (CRT-D) upgrade (n = 215) or ICD (n = 145). Primary [HF hospitalization (HFH), all-cause mortality, or <15% reduction of left ventricular end-systolic volume] and secondary outcomes were investigated. At enrolment, 131 (36%) patients had AF, who had an increased risk for HFH as compared with those with SR [adjusted hazard ratio (aHR) 2.99; 95% confidence interval (CI) 1.26–7.13; P = 0.013]. The effect of CRT-D upgrade was similar in patients with AF as in those with SR [AF adjusted odds ratio (aOR) 0.06; 95% CI 0.02–0.17; P < 0.001; SR aOR 0.13; 95% CI 0.07–0.27; P < 0.001; interaction P = 0.29] during the mean follow-up time of 12.4 months. Also, it decreased the risk of HFH or all-cause mortality (aHR 0.33; 95% CI 0.16–0.70; P = 0.003; interaction P = 0.17) and improved the echocardiographic response (left ventricular end-diastolic volume difference −49.21 mL; 95% CI −69.10 to −29.32; P < 0.001; interaction P = 0.21). In HFrEF patients with AF and PM/ICD with high RV pacing burden, CRT-D upgrade decreased the risk of HFH and improved reverse remodelling when compared with ICD, similar to that seen in patients in SR. In AF patients CRT-D upgrade reduced the risk of mortality or HF hospitalization as compared with ICD, additionally echocardiographic parameters, symptoms, and NT-proBNP levels improved. However, the risk of HF hospitalization was higher in AF patients when compared with SR. AF, atrial fibrillation or flutter; aOR, adjusted odds ratio; aHR, adjusted hazard ratio; CI, confidence interval; CRT-D, cardiac resynchronization therapy with defibrillator; ICD, implantable cardioverter defibrillator; HF, heart failure; HFrEF, heart failure with reduced ejection fraction; LVESV, left ventricular end-systolic volume; NT-proBNP, N-terminal pro b-type natriuretic peptide; PCI, percutaneous coronary intervention; PM, pacemaker; RV, right ventricular; SR, sinus rhythm.

11 April 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
GHGerhard Hindricks
Gerhard Hindricks
DTDominic A.M.J. Theuns
Dominic A.M.J. Theuns
DBDavid Bar-Lev
David Bar-Lev
IAIgnasi Anguera
Ignasi Anguera
FPFélix Alejandro Ayala Paredes
Félix Alejandro Ayala Paredes
Andreas BollmannAndreas Bollmann
Andreas Bollmann
To allow timely initiation of anticoagulation therapy for the prevention of stroke, the European guidelines on atrial fibrillation (AF) recommend remote monitoring (RM) of device-detected atrial high-rate episodes (AHREs) and progression of arrhythmia duration along pre-specified strata (6 min…<1 h, 1 h…<24 h, ≥ 24 h). We used the MATRIX registry data to assess the capability of a single-lead implantable cardioverter-defibrillator (ICD) with atrial sensing dipole (DX ICD system) to follow this recommendation in patients with standard indication for single-chamber ICD. In 1841 DX ICD patients with daily automatic RM transmissions, electrograms of first device-detected AHREs per patient in each duration stratum were adjudicated, and the corresponding positive predictive values (PPVs) for the detections to be true atrial arrhythmia were calculated. Moreover, the incidence and progression of new-onset AF was assessed in 1451 patients with no AF history. A total of 610 AHREs ≥6 min were adjudicated. The PPV was 95.1% (271 of 285) for episodes 6min…<1 h, 99.6% (253/254) for episodes 1 h…<24 h, 100% (71/71) for episodes ≥24 h, or 97.5% for all episodes (595/610). The incidence of new-onset AF was 8.2% (119/1451), and in 31.1% of them (37/119), new-onset AF progressed to a higher duration stratum. Nearly 80% of new-onset AF patients had high CHA2DS2-VASc stroke risk, and 70% were not on anticoagulation therapy. Age was the only significant predictor of new-onset AF. A 99.7% detection accuracy for AHRE ≥1 h in patients with DX ICD systems in combination with daily RM allows a reliable guideline-recommended screening for subclinical AF and monitoring of AF-duration progression.

30 September 2003 in Annals of Noninvasive Electrocardiology
Verified
Journal Article
Open access
PDF file
ICIwona Cygankiewicz
Iwona Cygankiewicz
JWJerzy Krzysztof Wranicz
Jerzy Krzysztof Wranicz
JZJanusz Zaslonka
Janusz Zaslonka
HBHalina Bolinska
Halina Bolinska
WZWojciech Zareba
Wojciech Zareba
Background: The aim of this study is to evaluate the association between heart rate turbulence (HRT) parameters and clinical characteristics of coronary artery disease (CAD) patients. Methods and Results: In 122 patients (mean age 62 ± 9 years) with angiographically documented CAD, 24‐hour Holter monitoring with HRT analysis was performed to evaluate turbulence onset (TO) and turbulence slope (TS). There was a significant correlation between TO and TS (P =−0.31; P < 0.001). According to quartile values, TO ≥−0.37% and TS ≤ 4.25 ms/RR were considered as abnormal in this patient population. Average values of TO were higher and TS lower in patients over 60 years, in patients with a past history of myocardial infarction and in those with EF < 40%. Considering pharmacotheraphy, higher (better) values of TS were observed in patients on statins, nitrates, and beta‐blockers while lower TS values were noted in patients on calcium blockers. Patients with abnormal parameters of HRT compared to group with normal HRT values were characterized by features of more advanced CAD: age over 60 years (75% vs 49%), past history of MI (75% vs 64%), and EF < 40% (25% vs 3%). Multivariate analysis revealed age > 60 years (OR 1.27; P = 0.002) and EF < 40% (OR 1.39; P = 0.001) as independent clinical factors associated with abnormal HRT parameters. Conclusions: HRT parameters are influenced by clinical characteristics and pharmacotherapy of studied patients with TS more than abnormal TO depending on clinical characteristics of patients. Advanced age, prior myocardial infarction and left ventricular dysfunction are key factors influencing values of HRT parameters.

12 February 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KKKrzysztof Kaczmarek
Krzysztof Kaczmarek
ICIwona Cygankiewicz
Iwona Cygankiewicz
WSWitold Streb
Witold Streb
RPRafal Plaksej
Rafal Plaksej
PJPiotr Jakubowski
Piotr Jakubowski
MGMarek Grygier
Marek Grygier
We analyzed clinical experience with percutaneous closure of instances of left atrial appendage with thrombus (LAAT) irresponsive to antithrombotic therapy in patients treated in three high-volume cardiology centers. Clinical and procedural data regarding consecutive patients who underwent percutaneous left atrial appendage closure (PLAAC) due to LAAT were retrospectively analyzed. The study population consisted of 17 patients (11 men; 68 ± 14 years; CHA2DS2VASC 4.7 ± 1.9; HASBLED 3 (0–5)) with LAAT confirmed by transesophageal echocardiography, and included 5 patients with mechanical heart valves. Most of the patients (94.1%) received anticoagulation therapy before PLAAC. All LAATs were located in distal portions of the appendage and occupied less than 30% of its volume. Occluding-device implantation was successful in 17 patients; in one, a residual leak was disclosed. Appropriate positioning of occluders required more than 1 attempt in 6 individuals (35.3%); in 3 others (17.6%), the subjects’ devices had contact with thrombi. No procedural complications were noted. Midterm follow-up (median: 10 months) revealed no procedure-related complications or clinically diagnosed thromboembolism. Transesophageal echocardiography (TEE) performed after six months revealed device-related thrombus in one patient. We concluded that LAAT irresponsive to antithrombotic therapy might be effectively treated with PLAAC, even in patients with mechanical-valve prostheses.