Jorge Lopes Storniolo

Dr. Jorge Lopes Storniolo

Lab Sperimentale di Fisiopatologia Neuromotoria, IRCSS Istituto Auxologico Italiano, Meda, Italy
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2021 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
Jorge Lopes StornioloJorge Lopes Storniolo
Jorge Lopes Storniolo
Beatrice CairoBeatrice Cairo
Beatrice Cairo
Alberto PortaAlberto Porta
Alberto Porta
PCPaolo Cavallari
Paolo Cavallari
Cardiac autonomic control is commonly assessed via the analysis of fluctuations of the temporal distance between two consecutive R-waves (RR). Cardiac regulation assessment following high intensity physical exercise is difficult due to RR non-stationarities. The very short epoch following maximal sprint exercise when RR remains close to its lowest value, i.e., the PLATEAU, provides the opportunity to evaluate cardiac regulation from stationary RR sequences. The aim of the study is to evaluate cardiac autonomic control during PLATEAU phase following 60-m maximal sprint and compare the results to those derived from sequences featuring the same length as the PLATEAU and derived from pre-exercise and post-exercise periods. These sequences were referred to as PRE and POST sequences. RR series were recorded in 21 subjects (age: 24.9 ± 5.1 years, 15 men and six women). We applied a symbolic approach due to its ability to deal with very short RR sequences. The symbolic approach classified patterns formed by three RRs according to the sign and number of RR variations. Symbolic markers were compared to more classical time and frequency domain indexes. Comparison was extended to simulated signals to explicitly evaluate the suitability of methods to deal with short variability series. A surrogate test was applied to check the null hypothesis of random fluctuations. Over simulated data symbolic analysis was able to separate dynamics with different spectral profiles provided that the frame length was longer than 10 cardiac beats. Over real data the surrogate test indicated the presence of determinism in PRE, PLATEAU, and POST sequences. We found that the rate of patterns with two variations with unlike sign increased during PLATEAU and in POST sequences and the frequency of patterns with no variations remained unchanged during PLATEAU and decreased in POST compared to PRE sequences. Results indicated a sustained sympathetic control along with an early vagal reactivation during PLATEAU and a shift of the sympathovagal balance toward vagal predominance in POST compared to PRE sequences. Time and frequency domains markers were less powerful because they were dominated by the dramatic decrease of RR variance during PLATEAU.

1 February 2017 in Journal of Applied Biomechanics
Verified
Journal Article
Closed access
GPGaspare Pavei
Gaspare Pavei
ESElena Seminati
Elena Seminati
Jorge Lopes StornioloJorge Lopes Storniolo
Jorge Lopes Storniolo
Leonardo Alexandre Peyré-TartarugaLeonardo Alexandre Peyré-Tartaruga
Leonardo Alexandre Peyré-Tartaruga
We compared running mechanics parameters determined from ground reaction force (GRF) measurements with estimated forces obtained from double differentiation of kinematic (K) data from motion analysis in a broad spectrum of running speeds (1.94–5.56 m⋅s–1). Data were collected through a force-instrumented treadmill and compared at different sampling frequencies (900 and 300 Hz for GRF, 300 and 100 Hz for K). Vertical force peak, shape, and impulse were similar between K methods and GRF. Contact time, flight time, and vertical stiffness (kvert) obtained from K showed the same trend as GRF with differences < 5%, whereas leg stiffness (kleg) was not correctly computed by kinematics. The results revealed that the main vertical GRF parameters can be computed by the double differentiation of the body center of mass properly calculated by motion analysis. The present model provides an alternative accessible method for determining temporal and kinetic parameters of running without an instrumented treadmill.

20 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Edilson Fernando de BorbaEdilson Fernando de Borba
Edilson Fernando de Borba
Jorge Lopes StornioloJorge Lopes Storniolo
Jorge Lopes Storniolo
Serena CerfoglioSerena Cerfoglio
Serena Cerfoglio
Paolo CapodaglioPaolo Capodaglio
Paolo Capodaglio
Veronica CimolinVeronica Cimolin
Veronica Cimolin
PCPaolo Cavallari
Paolo Cavallari
Quantitative gait analysis is essential for understanding motor function and guiding clinical decisions. While marker-based motion capture (MoCap) systems are accurate, they are costly and require specialized facilities. OpenCap, a markerless alternative, offers a more accessible approach; however, its reliability across different walking speeds remains uncertain. This study assessed the agreement between OpenCap and MoCap in measuring spatiotemporal parameters, joint kinematics, and center of mass (CoM) displacement during level walking at three speeds: slow, self-selected, and fast. Fifteen healthy adults performed multiple trials simultaneously, recorded by both systems. Agreement was analyzed using intraclass correlation coefficients (ICC), minimal detectable change (MDC), Bland–Altman analyses, root mean square error (RMSE), Statistical Parametric Mapping (SPM), and repeated-measures ANOVA. Results indicated excellent agreement for spatiotemporal variables (ICC ≥ 0.95) and high consistency for joint waveforms (RMSE < 2°) and CoM displacement (RMSE < 6 mm) across all speeds. However, the joint range of motion (ROM) showed lower reliability, especially at the hip and ankle, at higher speeds. ANOVA revealed no significant System × Speed interactions for most variables, though a significant effect of speed was noted, with OpenCap underestimating walking speed more at fast speeds. Overall, OpenCap is a valuable tool for gait assessment, very accurate for spatiotemporal data and CoM displacement. Still, caution should be taken when interpreting joint kinematics and speed at different walking speeds.

1 December 2015 in Journal of Applied Biomechanics
Verified
Journal Article
Closed access
GFGabriela Fischer
Gabriela Fischer
Jorge Lopes StornioloJorge Lopes Storniolo
Jorge Lopes Storniolo
Leonardo Alexandre Peyré-TartarugaLeonardo Alexandre Peyré-Tartaruga
Leonardo Alexandre Peyré-Tartaruga
The information leader in physical activity and health.

29 January 2019 in European Journal of Physiotherapy
Verified
Journal Article
Closed access
RBRenata L. Bona
Renata L. Bona
NGNatalia Gomenuka
Natalia Gomenuka
Jorge Lopes StornioloJorge Lopes Storniolo
Jorge Lopes Storniolo
ABArtur Bonezi
Artur Bonezi
CBCarlo M Biancardi
Carlo M Biancardi
Purpose: The aim of this study was to investigate the influence of walking speed on the pendular mechanism, cost of transport, mechanical efficiency and mechanical work in adults with lower-limb amputation, compared to a control group. Methods: Observational, cross sectional study. Ten subjects from an amputee rehabilitation clinic, with the same prosthetic knee and foot and ten healthy subjects were selected to form the experimental and the control group, respectively. Tridimensional kinematics data and oxygen uptake were collected simultaneously at five speeds: the self-selected walking speed (SSWS), two speeds above and below. Results: In the experimental group, the cost of transport was higher than in controls. Contrary to controls, in experimental group the minimum cost of transport and the maximum recovery did not coincide to the SSWS, but were reached at the maximum speed of the protocol. The mechanical efficiency in experimental group was lower, while the external mechanical work and pendular transduction were higher than in controls. Conclusions: The clinical relevance of these results is the concept, also supported by other studies, that interventions headed to increase the SSWS in the experimental group also increase and optimise the energetic economy and the pendulum efficiency of their locomotion.

3 November 2025 in Biomechanics
Verified
Journal Article
Open access
PDF file
Serena CerfoglioSerena Cerfoglio
Serena Cerfoglio
Jorge Lopes StornioloJorge Lopes Storniolo
Jorge Lopes Storniolo
Edilson Fernando de BorbaEdilson Fernando de Borba
Edilson Fernando de Borba
PCPaolo Cavallari
Paolo Cavallari
MGManuela Galli
Manuela Galli
Veronica CimolinVeronica Cimolin
Veronica Cimolin
Background: Gait analysis plays a key role in detecting and monitoring neurological, musculoskeletal, and orthopedic impairments. While marker-based motion capture (MoCap) systems are the gold standard, their cost and complexity limit routine use. Recent advances in computer vision have enabled markerless smartphone-based approaches. OpenCap, an open-source platform for 3D motion analysis, offers a potentially accessible alternative. This review summarizes current evidence on its accuracy, limitations, and clinical applicability in gait assessment. Methods: A search was performed in major scientific databases to identify studies published from OpenCap’s release in 2023 to June 2025. Articles were included if they applied OpenCap to human gait and reported quantitative biomechanical outcomes. Both validation and applied studies were considered, and findings were synthesized qualitatively. Results: Nine studies were included. Validation research showed OpenCap achieved generally acceptable accuracy kinematics (RMSE 4–6°) in healthy gait, while increased errors were reported for pathological gait patterns. Applied studies confirmed feasibility in different clinical conditions, though trial-to-trial variability remained higher than MoCap, and test–retest reliability was moderate, with minimal detectable changes often exceeding 5°, limiting sensitivity to subtle clinical differences. Conclusions: OpenCap is a promising, low-cost tool for gait screening, remote monitoring, and tele-rehabilitation. Its strengths lie in accessibility and feasibility outside laboratory settings, but limitations in multiplanar accuracy, pathological gait assessment, and kinetic estimation currently preclude its replacement of MoCap in advanced clinical applications. Further research should refine algorithms and standardize protocols to improve robustness and clinical utility.