In the design process of an arch bridge, the designer may decide to stiffen the hangers linking the arch and the deck, usually in order to reduce the internal forces or the deflections. In this paper, the effect of stiffened hangers on the longitudinal in-plane structural behavior of arch bridges is studied. Then, the effect of the stiffness of the hangers and the relevance of the arch–deck relative stiffness are shown. The paper also describes how stiff hangers with a hinge—either at the bottom or the top—combine very high structural efficiency and ease of execution. Once the advantages of stiff hangers are described and a possible drawback is highlighted. The problem may arise for stiffened hangers, as the bending moments near the ends of the deck might become more adverse for symmetrical load cases than for asymmetrical load distributions, as this usually occurs in arch bridges. To address this problem, this paper suggests a novel solution by designing a combination of fixed and pinned hangers, which can be as efficient as a configuration where all the hangers are fixed, while simultaneously reducing the bending moment at the end zones of the deck.
Hydrogen sulfide (H2S) generated in sewer networks induces corrosion which today constitutes the main cause of deterioration of concrete pipes. Information regarding the H2S concentration inside sewer networks, as well as its control and reduction, has become one of the most important concerns in sanitation systems management nowadays. Modeling sulfide dynamics is the key to understanding corrosion processes. A dynamic model (called EMU-SANETSUL) was developed to calculate the H2S concentration in both the water and the gas phases of the main sewers of the city of Murcia (Spain). The model was calibrated with data from field measurements taken from both the gas phase and wastewater. Samples were taken in the network from 2016 to 2019. The model achieved an accuracy index and error index in the ranges of 57% and 15%, respectively. Empirical equations of reaction are used, and calibration parameters are detailed. The code uses an explicit discretization technique, named the Discrete Volume Element Method (DVEM). A map with the annual average concentration of H2S at the gas phase inside each pipe of the simulated network is presented. Values are compared with the mechanical deterioration inventory from closed-circuit television (CCTV) inspections performed by the Municipal Sanitation Company of the city of Murcia (EMUASA). Mechanical deterioration of pipes has diverse causes, including corrosion of pipes by H2S. Sections with high H2S concentrations that match with mechanical wear can be considered susceptible to being prioritized when rehabilitation works are being planned. Therefore, H2S concentration modeling provides valuable information for asset management of the sewer network.
In tied-arch bridges with a single arch, the deck is usually suspended from the arch by means of a single set of cables, pinned at both ends and anchored to the centerline, using either vertical or Nielsen-type hanger arrangements. When properly designed, this layout can significantly reduce forces and deflections under loads that are symmetrical with respect to the plane of the arch. However, it does not contribute to the support of nonsymmetrical loads, such as eccentric loads distributions or wind loading, and does not reduce the sensibility of the arch to out-of-plane buckling. Thus, this paper studies how a cable arrangement composed of two sets of lateral hangers, attached to both edges of a deck, can be very suitable to address these problems. Firstly, it is demonstrated that the structural behavior under symmetrical loads improves with respect to the bridge with centered hangers. Secondly, it is shown how nonsymmetric loads are partially carried by structural systems (such as the transversal stiffness both of the arch and the deck) that would remain inactive for tied-arch bridges with centered hangers, leading to a general reduction in the forces and the deflections of the bridge and in the critical buckling load of the arch.
A diagonal arch bridge (DAB) is a particular case of arch bridge where the arch is rotated about a vertical axis passing through its crown so that each springing lies on a different side of the deck. A perpendicular arch bridge (PAB) is a particular case of DAB where the arch is rotated so that the arch plan is perpendicular to the deck axis. This paper includes a table of built bridges since 1989 and outlines the historical evolution of this type of bridge. Two main trends can be distinguished—one approach is focused on structural efficiency and the other is based on making aesthetics prevail, which often leads to structurally inefficient solutions. The main geometrical parameters are identified and the effect of the angle of rotation about a vertical axis is studied. Design constraints, such as the clearance requirements, are highlighted. In addition, the main structural systems, such as out-of-plane behavior, are identified and qualitatively studied, as an orientation for designers and a first step in future studies.
Se presenta y detalla un método original de predimensionamiento en el plano de secciones metálicas simétricas basado en primer lugar en un tratamiento simplificado de la geometría de la sección. Esto posibilita que cualquier criterio de predimensionamiento que necesite el proyectista, basado en la normativa y su propia experiencia, pueda ser representado gráficamente. Esta doble aproximación lleva a un predimensionamiento muy intuitivo, que identifica claramente los criterios que condicionan las dimensiones de la sección y minimiza eficazmente el peso propio de la sección transversal. El método resulta especialmente eficaz cuando se han de verificar simultáneamente varios criterios, como los relacionados con la rigidez de la sección, limitación de tensiones o rotura. Se acompaña de dos ejemplos ilustrativos y recomendaciones sobre el diseño. Además, se destaca la importancia de un adecuado criterio estructural en las primeras etapas del proyecto.
In this paper, we present a novel iterative method that minimizes the weight of an all-steel arch bridge during the in-plane preliminary design stage. The behavior of the bridge is assumed to be contained within the plane of the arch. The preliminary design is assumed to be governed by the maximum allowable static deflection at a given checkpoint at the deck under a simplified load combination selected by the designer. The designer can select variables commonly used in preliminary design, such as the web slenderness of the cross-sections of both the arch and the deck and their relative flexural stiffness levels. Moreover, the general method is particularized for tied-arch bridges with vertical hangers: its iterative flowchart is adapted, an approximate analytical formulation that allows manual calculations is provided, and a parametric study that illustrates the effect of the main variables on the weight of the bridge is carried out. The main design recommendations drawn from this research for minimizing the weight of a bridge are as follows: a rise/span ratio between 1/5 and 1/7; cross-sections with significantly different stiffnesses in the arch and deck, ideally with highly flexible arches; and cross-sections with the thinnest possible webs.