Javier Sosa

Dr. Javier Sosa

Institute for Applied Microelectronics (IUMA) - Universidad de Las Palmas de Gran Canaria (ULPGC)
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2019 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
JMJuan Antonio Martos-Sitcha
Juan Antonio Martos-Sitcha
Javier SosaJavier Sosa
Javier Sosa
DRDailos Ramos-Valido
Dailos Ramos-Valido
FBFrancisco Javier Bravo
Francisco Javier Bravo
CCCristina Carmona-Duarte
Cristina Carmona-Duarte
JPJaume Pérez-Sánchez
Jaume Pérez-Sánchez
Integration of technological solutions aims to improve accuracy, precision and repeatability in farming operations, and biosensor devices are increasingly used for understanding basic biology during livestock production. The aim of this study was to design and validate a miniaturized tri-axial accelerometer for non-invasive monitoring of farmed fish with re-programmable schedule protocols. The current device (AE-FishBIT v.1s) is a small (14 mm × 7 mm × 7 mm), stand-alone system with a total mass of 600 mg, which allows monitoring animals from 30 to 35 g onwards. The device was attached to the operculum of gilthead sea bream (Sparus aurata) and European sea bass (Dicentrarchus labrax) juveniles for monitoring their physical activity by measurements of movement accelerations in x- and y-axes, while records of operculum beats (z-axis) served as a measurement of respiratory frequency. Data post-processing of exercised fish in swimming test chambers revealed an exponential increase of fish accelerations with the increase of fish speed from 1 body-length to 4 body-lengths per second, while a close relationship between oxygen consumption (MO2) and opercular frequency was consistently found. Preliminary tests in free-swimming fish kept in rearing tanks also showed that device data recording was able to detect changes in daily fish activity. The usefulness of low computational load for data pre-processing with on-board algorithms was verified from low to submaximal exercise, increasing this procedure the autonomy of the system up to 6 h of data recording with different programmable schedules. Visual observations regarding tissue damage, feeding behavior and circulating levels of stress markers (cortisol, glucose, and lactate) did not reveal at short term a negative impact of device tagging. Reduced plasma levels of triglycerides revealed a transient inhibition of feed intake in small fish (sea bream 50–90 g, sea bass 100–200 g), but this disturbance was not detected in larger fish. All this considered together is the proof of concept that miniaturized devices are suitable for non-invasive and reliable metabolic phenotyping of farmed fish to improve their overall performance and welfare. Further work is underway for improving the attachment procedure and the full device packaging.

1 August 2020 in Computers and Electronics in Agriculture
Verified
Journal Article
Closed access
MFMiguel A. Ferrer
Miguel A. Ferrer
JCJosep A. Calduch-Giner
Josep A. Calduch-Giner
MDMoises Diaz
Moises Diaz
Javier SosaJavier Sosa
Javier Sosa
EREnrique Rosell-Moll
Enrique Rosell-Moll
JPJaume Pérez-Sánchez
Jaume Pérez-Sánchez

21 June 2004
Verified
Conference Paper
Closed access
JGJ.C. Garcia
J.C. Garcia
JMJuan A. Montiel-Nelson
Juan A. Montiel-Nelson
Javier SosaJavier Sosa
Javier Sosa
HNH. Navarro
H. Navarro

28 November 2023 in IEEE Access
Verified
Journal Article
Open access
HSHector Solar
Hector Solar
ABAndoni Beriain
Andoni Beriain
RBRoc Berenguer
Roc Berenguer
Javier SosaJavier Sosa
Javier Sosa
JMJuan A. Montiel-Nelson
Juan A. Montiel-Nelson
This paper presents a comprehensive overview and analysis of the state-of-the-art (SoA) in semi-passive or Battery-Assisted (BAP) Ultra-High Frequency (UHF) Radio Frequency Identification (RFID) sensor tags compliant with EPC Global G2/ISO-18000C. These tags operate on the same communication principle as fully passive sensor tags but incorporate a battery or an energy harvesting module. This additional power source extends communication ranges and enables power demanding applications using low power microcontrollers (MCUs) and higher-end sensors. This article also analyzes various key features, including tag integrated circuit (IC) architecture, types of energy harvesting modules, and communication range. The main conclusions are threefold. Firstly, selecting the appropriate tag IC requires a careful analysis its features such as sensitivity, sensor interfaces or data logging capabilities. For instance, among the solutions examined in the SoA, half of them opted for a tag IC capable of MCU communication via SPI or I2C buses. Secondly, it is essential to assess both the forward and backward communication links to leverage the sensitivity of the tag IC in BAP mode. Interestingly, only one third of the solutions in the SoA achieved the theoretical communication range anticipated by the tag IC sensitivity. Finally, an energy budget analysis is required to ensure that the energy generation suffices to meet the energy requirements of the tag. While most solutions rely on batteries as the energy source and analyze battery lifespan, only a few studies employing energy harvesters conduct an energy budget analysis due to the additional complexity involved.

13 September 2015 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
Javier SosaJavier Sosa
Javier Sosa
JMJuan A. Montiel-Nelson
Juan A. Montiel-Nelson
RPR. Pulido
R. Pulido
JGJose C. Garcia-Montesdeoca
Jose C. Garcia-Montesdeoca
A blood pressure sensor suitable for wireless biomedical applications is designed and optimized. State-of-the-art blood pressure sensors based on piezoresistive transducers in a full Wheatstone bridge configuration use low ohmic values because of relatively high sensitivity and low noise approach resulting in high power consumption. In this paper, the piezoresistance values are increased in order to reduce by one order of magnitude the power consumption in comparison with literature approaches. The microelectromechanical system (MEMS) pressure sensor, the mixed signal circuits signal conditioning circuitry, and the successive approximation register (SAR) analog-to-digital converter (ADC) are designed, optimized, and integrated in the same substrate using a commercial 1 μm CMOS technology. As result of the optimization, we obtained a digital sensor with high sensitivity, low noise (0.002 μV/Hz), and low power consumption (358 μW). Finally, the piezoresistance noise does not affect the pressure sensor application since its value is lower than half least significant bit (LSB) of the ADC.

10 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
GSGraciela Santana Sosa
Graciela Santana Sosa
JAJudith Santana Abril
Judith Santana Abril
Javier SosaJavier Sosa
Javier Sosa
JMJuan A. Montiel-Nelson
Juan A. Montiel-Nelson
TBTomás Bautista
Tomás Bautista
In this paper, we present the design of a practical underwater sensor network for offshore fish farm cages. An overview of the current structure of an offshore fish farm, applied sensor network solutions, and their weaknesses are given. A mixed wireless–wired approach is proposed to mitigate the problem of wire breakage in underwater wired sensor networks. The approach is based on the serial arrangement of identical sections with wired and wireless interconnections areas. Wireless section alleviates underwater maintenance operations when cages are damaged. The analytical model of the proposed solution is studied in terms of maximum power transfer efficiency and the general formulas of the current in their transmitting antennas and sensor nodes are provided. Subsequently, based on simulations, the effects of parasitic resistance across the network are evaluated. A practical underwater sensor network to reach the 30 m depth with sensor nodes distanced 6 m is used to determine the proposal compliance with the ISO 11784/11785 HDX standard in its normal operation. Taking into account the cable breakage scenario, the results from experiments demonstrate the robustness of the proposed approach to keep running the sensor nodes that are located before the short circuit. Sensor node run time is reduced only 4.07% at most using standard values when a cable breakage occurs at the second deepest section.