Ramona Jeitler

Dr. Ramona Jeitler

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2024 in Molecular Pharmaceutics
Verified
Journal Article
Open access
Ramona JeitlerRamona Jeitler
Ramona Jeitler
CGChristina Glader
Christina Glader
GKGerhard Koenig
Gerhard Koenig
JKJay Kaplan
Jay Kaplan
CTCarolin Tetyczka
Carolin Tetyczka
EREva Roblegg
Eva Roblegg
The efficacy of nanostructured lipid carriers (NLC) for drug delivery strongly depends on their stability and cell uptake. Both properties are governed by their compositions and internal structure. To test the effect of the lipid composition of NLC on cell uptake and stability, three kinds of liquid lipids with different degrees of unsaturation are employed. After ensuring homogeneous size distributions, the thermodynamic characteristics, stability, and mixing properties of NLC are characterized. Then the rates and predominant pathways of cell uptake are determined. Although the same surfactant is used in all cases, different uptake rates are observed. This finding contradicts the view that the surface properties of NLC are dominated by the surfactant. Instead, the uptake rates are explained by the structure of the nanocarrier. Depending on the mixing properties, some liquid lipids remain inside the nanocarrier, while other liquid lipids are present on the surface. Nanocarriers with liquid lipids on the surface are taken up more readily by the cells. This shows that the engineering of efficient lipid nanocarriers requires a delicate balance of interactions between all components of the nanocarrier on the molecular level.

6 October 2024 in European Journal of Pharmaceutical Sciences
Verified
Journal Article
Open access
CGChristina Glader
Christina Glader
Ramona JeitlerRamona Jeitler
Ramona Jeitler
YWYan Wang
Yan Wang
CTCarolin Tetyczka
Carolin Tetyczka
MZManuel Zettl
Manuel Zettl
EREva Roblegg
Eva Roblegg
A variety of strategies for producing high-quality nanoparticles have been reported in recent years. Batch-based bottom-up and top-down technologies are generally the most efficient methods, but present a number of challenges, particularly in terms of variability, safety, sustainability and large-scale production. In this study, a scalable, semi-continuous production line was built by connecting individual processing units, including a high shear mixing device, the Microfluidizer® technology and a cooling system. Each unit was equipped with an adequate temperature control to allow solvent-free production of solid lipid nanoparticles (consisting of Precirol® ATO 5 or Gelucire® 43/01) and nanostructured lipid carriers (additionally comprising Labrafac™ lipophile WL 1349). Subsequently, critical formulation parameters and critical process parameters (CPPs) of the individual processing units and their effects on particle size (i.e., critical quality attribute (CQA)) were investigated to identify appropriate input parameters for the subsequent Design of Experiment (DoE) studies conducted after linking the process units to a semi-continuous production line. For particle size monitoring, spatially resolved dynamic light scattering (SR-DLS) measurements were conducted and compared to standard DLS measurements to evaluate the applicability of SR-DLS as an inline monitoring tool. It was found that matrix composition, emulsifier concentration, pressure and number of cycles when processing through Microfluidizer® processor were the most influencing parameters. By optimizing these parameters, five-times higher throughputs could be achieved by the semi-continuous manufacturing line. In addition, the particle size measurements with SR-DLS confirmed the feasibility of implementing this technology for real-time particle size monitoring as an important safety factor in quality control.

22 May 2025 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
CGChristina Glader
Christina Glader
Ramona JeitlerRamona Jeitler
Ramona Jeitler
YWYan Wang
Yan Wang
RTRemy van Tuijn
Remy van Tuijn
AGAlbert Grau-Carbonell
Albert Grau-Carbonell
EREva Roblegg
Eva Roblegg
Background/Objectives: Continuous manufacturing is gaining importance in the nanopharmaceutical field, offering improved process efficiency and product consistency. To fully leverage its potential, the integration of Process Analytical Technology (PAT) tools is essential for real-time quality control and robust process monitoring. Among the critical quality attributes (CQAs) of nanosystems, particle size plays a key role in ensuring product consistency and performance. However, real-time size monitoring remains challenging due to complex process dynamics and nanosystem heterogeneity. Methods: This study evaluates the applicability of conventional Dynamic Light Scattering (DLS) and spatially resolved DLS (SR-DLS) using the NanoFlowSizer (NFS) as PAT tools in a temperature-regulated top-down nano-production line. Various lipid-based nanosystems, including solid lipid nanoparticles (SLN), nanostructured lipid carriers (NLC), and nanoemulsions (NEs), were investigated. To ensure reliable implementation, key factors such as sample dilution, viscosity, focus position, measurement angle and temperature effects were systematically assessed for offline and at-line DLS using the Litesizer 500, as well as for offline, inline, and online SR-DLS using the NFS. Results: Offline screening confirmed that selecting the appropriate dilution medium and rate ensures measurement reliability. At-line methods provided an efficient alternative by enabling rapid final product control with minimal manual intervention. Inline and online monitoring further enhanced process efficiency by enabling real-time tracking of size, reducing waste, and allowing immediate process adjustments. Conclusions: This study demonstrates that integrating offline, at-line, in-line, and online DLS techniques allows for comprehensive product monitoring throughout the entire production line. This approach ensures a streamlined process, enables real-time adjustments, and facilitates reliable quality control after production and during storage.

18 May 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
CTCarolin Tetyczka
Carolin Tetyczka
SSSonja Sonja
Sonja Sonja
Ramona JeitlerRamona Jeitler
Ramona Jeitler
MAMarkus Absenger-Novak
Markus Absenger-Novak
CMClaudia Meindl
Claudia Meindl
EREva Roblegg
Eva Roblegg
Topical drug administration to the oral mucosa proves to be a promising treatment alternative for inflammatory diseases. However, disease-related changes in the cell barrier must be considered when developing such delivery systems. This study aimed at investigating the changes in the lining mucosa caused by inflammation and evaluating the consequences on drug delivery systems such as nanostructured lipid carriers (NLC). For this, TR146 cells were treated with inflammatory cytokines and bacterial components. Cell viability and integrity, reactive oxygen species (ROS), and interleukin (IL)-8 release were used as endpoints to assess inflammation. Translocation of phosphatidylserine, cytoskeletal arrangement, opening of desmosomes, and cell proliferation were examined. Transport studies with NLC were performed considering active and passive pathways. The results showed that IL-1ß and tumor necrosis factor α induced inflammation by increasing IL-8 and ROS production (22-fold and 2-fold). Morphologically, loss of cell–cell connections and formation of stress fibers and hyperplasia were observed. The charge of the cell membrane shifted from neutral to negative, which increased the absorption of NLC due to the repulsive interactions between the hydrophobic negative particles and the cell membrane on the one hand, and interactions with lipophilic membrane proteins such as caveolin on the other.

17 June 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
ASAtiđa Selmani
Atiđa Selmani
Ramona JeitlerRamona Jeitler
Ramona Jeitler
MAMichael Auinger
Michael Auinger
CTCarolin Tetyczka
Carolin Tetyczka
PBPeter Banzer
Peter Banzer
EREva Roblegg
Eva Roblegg
Biocompatible gold nanoparticles (AuNPs) are used in wound healing due to their radical scavenging activity. They shorten wound healing time by, for example, improving re-epithelialization and promoting the formation of new connective tissue. Another approach that promotes wound healing through cell proliferation while inhibiting bacterial growth is an acidic microenvironment, which can be achieved with acid-forming buffers. Accordingly, a combination of these two approaches appears promising and is the focus of the present study. Here, 18 nm and 56 nm gold NP (Au) were prepared with Turkevich reduction synthesis using design-of-experiments methodology, and the influence of pH and ionic strength on their behaviour was investigated. The citrate buffer had a pronounced effect on the stability of AuNPs due to the more complex intermolecular interactions, which was also confirmed by the changes in optical properties. In contrast, AuNPs dispersed in lactate and phosphate buffer were stable at therapeutically relevant ionic strength, regardless of their size. Simulation of the local pH distribution near the particle surface also showed a steep pH gradient for particles smaller than 100 nm. This suggests that the healing potential is further enhanced by a more acidic environment at the particle surface, making this strategy a promising approach.

9 February 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
CMClaudia Meindl
Claudia Meindl
MAMarkus Absenger-Novak
Markus Absenger-Novak
Ramona JeitlerRamona Jeitler
Ramona Jeitler
EREva Roblegg
Eva Roblegg
Eleonore FröhlichEleonore Fröhlich
Eleonore Fröhlich
The exposure to inhaled carbon nanotubes (CNT) may have adverse effects on workers upon chronic exposure. In order to assess the toxicity of inhaled nanoparticles in a physiologically relevant manner, an air–liquid interface culture of mono and cocultures of respiratory cells and assessment in reconstructed bronchial and alveolar tissues was used. The effect of CNT4003 reference particles applied in simulated lung fluid was studied in bronchial (Calu-3 cells, EpiAirway™ and MucilAir™ tissues) and alveolar (A549 +/−THP-1 and EpiAlveolar™ +/−THP-1) models. Cytotoxicity, transepithelial electrical resistance, interleukin 6 and 8 secretion, mucociliary clearance and ciliary beating frequency were used as readout parameters. With the exception of increased secretion of interleukin 6 in the EpiAlveolar™ tissues, no adverse effects of CNT4003 particles, applied at doses corresponding to the maximum estimated lifetime exposure of workers, in the bronchial and alveolar models were noted, suggesting no marked differences between the models. Since the doses for whole-life exposure were applied over a shorter time, it is not clear if the interleukin 6 increase in the EpiAlveolar™ tissues has physiological relevance.