Joanna Filippi

Dr. Joanna Filippi

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2024 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
Gianni AntonelliGianni Antonelli
Gianni Antonelli
Joanna FilippiJoanna Filippi
Joanna Filippi
MDMichele D’orazio
Michele D’orazio
GCGiorgia Curci
Giorgia Curci
PCPaola Casti
Paola Casti
Eugenio MartinelliEugenio Martinelli
Eugenio Martinelli
Microfluidic devices are increasingly widespread in the literature, being applied to numerous exciting applications, from chemical research to Point-of-Care devices, passing through drug development and clinical scenarios. Setting up these microenvironments, however, introduces the necessity of locally controlling the variables involved in the phenomena under investigation. For this reason, the literature has deeply explored the possibility of introducing sensing elements to investigate the physical quantities and the biochemical concentration inside microfluidic devices. Biosensors, particularly, are well known for their high accuracy, selectivity, and responsiveness. However, their signals could be challenging to interpret and must be carefully analysed to carry out the correct information. In addition, proper data analysis has been demonstrated even to increase biosensors' mentioned qualities. To this regard, machine learning algorithms are undoubtedly among the most suitable approaches to undertake this job, automatically learning from data and highlighting biosensor signals' characteristics at best. Interestingly, it was also demonstrated to benefit microfluidic devices themselves, in a new paradigm that the literature is starting to name "intelligent microfluidics", ideally closing this benefic interaction among these disciplines. This review aims to demonstrate the advantages of the triad paradigm microfluidics-biosensors-machine learning, which is still little used but has a great perspective. After briefly describing the single entities, the different sections will demonstrate the benefits of the dual interactions, highlighting the applications where the reviewed triad paradigm was employed.

20 June 2023 in Expert Systems with Applications
Verified
Journal Article
Closed access
PCP. Casti
P. Casti
SCS. Cardarelli
S. Cardarelli
MCM.C. Comes
M.C. Comes
MDM. D'ORazio
M. D'ORazio
Joanna FilippiJoanna Filippi
Joanna Filippi
Eugenio MartinelliEugenio Martinelli
Eugenio Martinelli

4 June 2024 in IEEE Sensors Letters
Verified
Journal Article
Closed access
AMAlessio Mostaccio
Alessio Mostaccio
FNFederica Naccarata
Federica Naccarata
FNFrancesca Maria Chiara Nanni
Francesca Maria Chiara Nanni
Joanna FilippiJoanna Filippi
Joanna Filippi
Eugenio MartinelliEugenio Martinelli
Eugenio Martinelli
GMGaetano Marrocco
Gaetano Marrocco
This paper introduces an epidermal antenna made of Laser-Induced Graphene (LIG) that is designed for hosting sensors within the UHF-RFID band (860-960 MHz). The upper bound performance is identified through numerical simulations and it is just 4 dB lower than a copper counterpart. Comparative assessments reveal that a significantly wider trace width is necessary to mitigate the intrinsic power loss of LIG. Furthermore, the paper offers the first experimental demonstration of a LIG-based wireless flexible plaster, integrating a temperature-oriented RFID IC encapsulated between skin-friendly elastomers. To address impedance matching challenges, a small coupled aluminum loop is employed to interface with the RFID IC. The device underwent testing on volunteers across different body parts with varying curvatures. Results indicate an averaged realized gain of -19 dBi, enabling a potential biophysical parameter collection from distances of up to 35 cm using a 3.2 W Effective Isotropic Radiated Power (EIRP). This performance could support diverse applications in home care and sportswear. However, a notable efficiency degradation (5 dB) persists due to the interconnection of the antenna to the microchip transponder, presenting an ongoing challenge for optimization.

22 March 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
PCPaola Casti
Paola Casti
Arianna MencattiniArianna Mencattini
Arianna Mencattini
Joanna FilippiJoanna Filippi
Joanna Filippi
MDMichele D'Orazio
Michele D'Orazio
MCMaria Colomba Comes
Maria Colomba Comes
Eugenio MartinelliEugenio Martinelli
Eugenio Martinelli
Pain is an alert state of the human body that can be conveyed to the external world through different modalities. A possible communication channel for human pain is represented by facial expressions, whose role in social interactions has been well established. In this work, the link between pain and transfer entropy, passing through facial expressions, is investigated. A new approach to the vision-based measurement of pain is presented, which is based on transfer entropy among the time-series of facial landmarks positions. The system is composed of three main blocks. A vision-based measurement block for the automatic landmarking and the generation of the time-series from the video-sequences; a second block for the evaluation of transfer entropy; and finally a classification model based on machine learning algorithms for pain assessment. A public database of video sequences of patients experiencing pain in a controlled scenario was used for the characterization of the system in terms of accuracy and precision. Different uncertainty contributions related to realistic signals interruptions and fluctuations were modelled and propagated to provide a comprehensive evaluation of the proposed measurement system. The obtained results indicate that transfer entropy-based approaches can provide great benefits in automatic pain assessment, opening new perspectives for remote management of patients.

7 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ACAlexandro Catini
Alexandro Catini
RCRosamaria Capuano
Rosamaria Capuano
GTGiuseppe Tancredi
Giuseppe Tancredi
GDGiulio Dionisi
Giulio Dionisi
DGDavide Di Giuseppe
Davide Di Giuseppe
Corrado Di NataleCorrado Di Natale
Corrado Di Natale
In aquaculture, the density of fish stock, use of feeding, and surrounding environmental conditions can easily result in an excessive concentration of harmful compounds that require continuous monitoring. Chemical sensors are available for most of these compounds, however, operative conditions and continuous monitoring in water make the development of sensors suitable for long and unattended deployments difficult. A possible solution is the development of engineered automatic labs where the uptake of sample and the contact with water is reduced and the use of a minimal quantity of reagents enables the implementation of reliable chemical assays. In this paper, a platform for automatic chemical assays is presented. The concept is demonstrated with the detection of nitrites based on the well-known colorimetric Griess reaction. The platform is centered around a lab-on-a-chip where reagents and water samples are mixed. The color of the reaction product is measured with low-cost optoelectronic components. Results show the feasibility of the approach with a minimum detectable concentration of about 0.1 mg/L which is below the tolerance level for aquaculture farms.

10 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MCMaria Colomba Comes
Maria Colomba Comes
Arianna MencattiniArianna Mencattini
Arianna Mencattini
DGDavide Di Giuseppe
Davide Di Giuseppe
Joanna FilippiJoanna Filippi
Joanna Filippi
MDMichele D'Orazio
Michele D'Orazio
Eugenio MartinelliEugenio Martinelli
Eugenio Martinelli
Cell motility is the brilliant result of cell status and its interaction with close environments. Its detection is now possible, thanks to the synergy of high-resolution camera sensors, time-lapse microscopy devices, and dedicated software tools for video and data analysis. In this scenario, we formulated a novel paradigm in which we considered the individual cells as a sort of sensitive element of a sensor, which exploits the camera as a transducer returning the movement of the cell as an output signal. In this way, cell movement allows us to retrieve information about the chemical composition of the close environment. To optimally exploit this information, in this work, we introduce a new setting, in which a cell trajectory is divided into sub-tracks, each one characterized by a specific motion kind. Hence, we considered all the sub-tracks of the single-cell trajectory as the signals of a virtual array of cell motility-based sensors. The kinematics of each sub-track is quantified and used for a classification task. To investigate the potential of the proposed approach, we have compared the achieved performances with those obtained by using a single-trajectory paradigm with the scope to evaluate the chemotherapy treatment effects on prostate cancer cells. Novel pattern recognition algorithms have been applied to the descriptors extracted at a sub-track level by implementing features, as well as samples selection (a good teacher learning approach) for model construction. The experimental results have put in evidence that the performances are higher when a further cluster majority role has been considered, by emulating a sort of sensor fusion procedure. All of these results highlighted the high strength of the proposed approach, and straightforwardly prefigure its use in lab-on-chip or organ-on-chip applications, where the cell motility analysis can be massively applied using time-lapse microscopy images.