Polyetheretherketone (PEEK) has become the biomaterial of choice for repairing craniofacial defects over time. Prospects for the point-of-care (POC) fabrication of PEEK customized implants have surfaced thanks to the developments in three-dimensional (3D) printing systems. Consequently, it has become essential to investigate the characteristics of these in-house fabricated implants so that they meet the necessary standards and eventually provide the intended clinical benefits. This study aimed to investigate the effects of the steam sterilization method on the dimensional accuracy of POC 3D-printed PEEK customized cranial implants. The objective was to assess the influence of standard sterilization procedures on material extrusion-based 3D-printed PEEK customized implants with non-destructive material testing. Fifteen PEEK customized cranial implants were fabricated using an in-house material extrusion-based 3D printer. After fabrication, the cranial implants were digitalized with a professional-grade optical scanner before and after sterilization. The dimensional changes for the 3D-printed PEEK cranial implants were analyzed using medically certified 3D image-based engineering software. The material extrusion 3D-printed PEEK customized cranial implants displayed no statistically significant dimensional difference with steam sterilization (p > 0.05). Evaluation of the cranial implants’ accuracy revealed that the dimensions were within the clinically acceptable accuracy level with deviations under 1.00 mm. Steam sterilization does not significantly alter the dimensional accuracy of the in-house 3D-printed PEEK customized cranial implants.
Cellulose is an abundant and sustainable material that is receiving more and more attention in different industries. In the context of additive manufacturing, it would be even more valuable. However, there are some challenges to overcome in processing cellulose-based materials. Therefore, this study used a new thermoplastic cellulose-based granulate to show its potential in filament extrusion and the fused filament fabrication printing process. Furthermore, the mechanical properties were investigated. It was shown that filaments with a suitable and uniform diameter could be produced. A parameter study for printing revealed that adhesion of the material on the bed and between layers was an issue but could be overcome with a suitable set of parameters. Tensile bars with different orientations of 0°, +/−45°, and 90° were printed and compared with injection-molded samples. It could be shown that different mechanisms (single strand breakage, shear failure) caused fracture for different printing orientations. In comparison with injection-molding, the printed parts showed lower mechanical properties (moduli of 74–95%, a tensile strength of 47–69%, and an elongation at break of 29–60%), but an improvement could be seen compared with earlier reported direct granule printing. The study showed that FFF is a suitable process for the new cellulose-based material to fabricate samples with good mechanical properties.
Temporal hollowing, which is a depression in the temple region, often results from trauma, surgical interventions, or neurological conditions. This condition is frequently observed after the resection of encephaloceles, where it can cause esthetic and functional challenges due to temporalis muscle atrophy and nerve palsy. We present a case of a 21-year-old female patient who developed temporal hollowing and complete atrophy of the right temporalis muscle following an encephalocele resection in childhood. The patient also suffered from right-sided frontal nerve branch palsy. To address this complex deformity, a patient-specific implant (PSI) made of hydroxyapatite (HA) was digitally designed and produced using 3D printing technology. The postoperative course was uneventful, with the implant securely positioned and the esthetic result highly satisfactory. This case highlights the potential of 3D printed PSIs in craniofacial reconstruction, offering an optimal solution for both functional restoration and esthetic enhancement. HA further ensures the long-term stability and integration of the implant, providing a promising approach for addressing complex craniofacial defects.
Introduction: Digital surgical planning in craniomaxillofacial (CMF) surgery requires biomedical engineers who can navigate complex 3D anatomical data confidently, yet most engineering training programmes still rely on static 2D methods. This study evaluated the usability, cognitive demands, and perceived educational outcomes of a clinically derived virtual reality (VR) surgical planning platform for master’s-level biomedical engineering students. Methods: A cross-sectional feasibility study was conducted assessing usability with the System Usability Scale (SUS), cognitive load with a modified NASA Task Load Index (NASA-TLX), and perceived educational outcomes using domain-specific rating scales, with open-ended responses analysed thematically. Results: Twelve of 15 enrolled students completed the survey (80% response rate). The platform achieved a mean SUS score of 72.5 (Above Average), with comparable scores across prior VR experience levels. All NASA-TLX demand dimensions remained below the scale midpoint. All participants rated VR as more engaging than traditional methods, and 91.7% rated the virtual anatomical models as realistic. Self-reported spatial reasoning benefits were most notable in landmark identification, while outcomes for translating digital-to-surgical planning were more limited. Haptic feedback was the most requested enhancement. Conclusions: VR surgical planning tools appear feasible to integrate into biomedical engineering training. Future studies should incorporate objective outcome measures and comparison groups to establish effectiveness.
Orbital reconstruction following trauma remains challenging due to complex three-dimensional (3D) anatomy and limited surgical access. While pre-fabricated titanium mesh is standard, it requires extensive intraoperative manipulation and produces imaging artifacts. The 3D-printed polyetheretherketone (PEEK) patient-specific implants (PSIs) offer potential advantages; however, limited data exists for the acceptance of PEEK PSIs by surgeons compared to other established techniques. Fourteen surgeons performed simulated orbital reconstructions on nine cadaveric heads comparing titanium mesh and the 3D-printed PEEK PSIs. Titanium mesh was used for Class II orbital floor fractures, while the 3D-printed PEEK PSIs (native and radiopaque formulations) were used for Class IV defects. Surgeons were blinded to the PEEK formulation type. Outcomes included operative efficiency, handling characteristics, fit quality, and mechanical stability using validated 5-point Likert scales and objective timing. The 3D-printed PEEK PSIs demonstrated faster procedure times (9.5 ± 5.3 vs. 11.2 ± 5.1 min) and superior fit quality (2.00 ± 1.04 vs. 2.18 ± 0.60) and mechanical stability (1.67 ± 0.49 vs. 1.91 ± 0.54), with 100% rated stable versus 91% for the titanium mesh. Surgeons could not distinguish between the native and radiopaque PEEK formulations. Most surgeons (64.3%) preferred situation-dependent material selection. The 3D-printed PEEK PSIs demonstrated advantages in handling, fit quality, and mechanical stability for complex defects, while the titanium mesh showed a lower learning curve for simple reconstructions. Radiopaque enhancement expands PEEK’s clinical utility without compromising handling.