Jorge Alberto Gomez Niebla

Mr. Jorge Alberto Gomez Niebla

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
JPJesus Alejandro Serrato Pedrosa
Jesus Alejandro Serrato Pedrosa
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
FCFrancisco Carrasco-Hernández
Francisco Carrasco-Hernández
Francisco Gallegos-FunesFrancisco Gallegos-Funes
Francisco Gallegos-Funes
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon
The study of the phenomena occurring in the plantar region is remarkably intriguing, especially when performing a normal gait cycle where the foot is under loading conditions. The effects presented in the foot while walking provide relevant indicators regarding clinical means for enhancing regular performance or rehabilitation therapies. Nevertheless, more than traditional methods are needed to biomechanically evaluate foot structural conditions, leading to an incomplete database for determining the patient’s needs so that advanced methodologies provide detailed medical assessment. Therefore, it is necessary to employ technological engineering tools to optimize biomechanical plantar pressure evaluations to reach suitable personalized treatments. This research initially evaluated numerically the pressure points in the foot sole region in each one of the five stance phases in a normal gait cycle. Medical imaging techniques were utilized to construct an anatomically accurate biomodel of the soft tissues of the right foot. The Finite Element Method was employed to predict peak plantar pressure in barefoot conditions for all stance phases; results from this case study presented a close alignment with gait experimental testing implemented to analyze the feasibility and validation of all mechanical considerations for the numerical analyses. Hence, having a solid foundation in the biomechanical behavior from the first case study close estimates, a 3D-printable patient-specific insole was designed and numerically analyzed to observe the mechanical response in the plantar critical zones utilizing a personalized orthotic device. Results from the second case study notably demonstrated a crucial decrement in excessive pressure values. Employing morphological customization orthopedics modeling combined with 3D-printable materials is revolutionizing assistive device design and fabrication techniques. The fundamental contribution of this research relies on deepening the knowledge of foot biomechanics from an interdisciplinary approach by numerically analyzing pressure distribution in critical regions for all five stances phases; thus, based on the methods employed, the results obtained contribute to the advances of patient-specific foot orthopedics.

22 October 2025 in Computation
Verified
Journal Article
Open access
PDF file
EGEdder Jair Rodriguez Granados
Edder Jair Rodriguez Granados
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
JNJorge Alberto Gomez Niebla
Jorge Alberto Gomez Niebla
JGJonathan Rodolfo Guereca-Ibarra
Jonathan Rodolfo Guereca-Ibarra
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon
This study presents a three-dimensional finite element (FE) analysis of the human foot bone structure under mid-stance loading during race walking. A subject-specific biomodel comprising 26 bones and over 40 ligaments was reconstructed from computed tomography (CT) data using Materialise Mimics Research 21.0 and 3-Matic Research 13.0, and subsequently analyzed in ANSYS Workbench 2024 R1. The model included explicit cortical, trabecular, and ligamentous volumes, each assigned linear-elastic, isotropic material properties based on biomechanical literature data. Boundary conditions simulated the mid-stance phase of race walking, applying a distributed plantar pressure of 0.25 MPa over the metatarsal and phalangeal regions. Numerical simulations yielded maximum total displacements of 0.00018 mm, maximum von Mises stresses of 0.171 MPa, and maximum strains of 2.5 × 10−5, all remaining well within the elastic range of bone tissue. The results confirm the model’s numerical stability, geometric fidelity, and capacity to represent physiologically realistic loading responses. The developed framework demonstrates the potential of high-resolution, image-based finite element modelling for investigating stress–strain patterns of the foot during athletic gait, and establishes a reproducible reference for future analyses involving pathological gait, orthotic optimisation, and musculoskeletal load assessment in sports biomechanics.

29 April 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
DHDavid Sánchez Hernández
David Sánchez Hernández
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
Gerardo Reyes-RuizGerardo Reyes-Ruiz
Gerardo Reyes-Ruiz
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
JOJulián Patiño Ortiz
Julián Patiño Ortiz
MOMiguel Patiño Ortiz
Miguel Patiño Ortiz
The rapid proliferation of unmanned aerial vehicles (UAVs) in urban and peri-urban environments has increased concern regarding drone-generated acoustic emissions, particularly in multirotor platforms whose tonal and broadband noise is strongly influenced by propeller blade geometry. This study presents a CFD-based aeroacoustic assessment framework to examine the influence of key geometric modifications on the acoustic signature of a representative multirotor propeller while preserving aerodynamic performance. A baseline quadrotor propeller was analyzed using Reynolds-Averaged Navier–Stokes (RANS) simulations coupled with the Ffowcs Williams–Hawkings (FW-H) acoustic analogy and Brooks–Pope–Marcolini (BPM) broadband noise estimation. The blade geometry was parameterized in terms of leading-edge sweep, tip chord, blade twist, and trailing-edge serration features, and representative low-noise configurations were evaluated under operating conditions ranging from 3000 to 6000 RPM and advance ratios between 0 and 0.3. The results indicate that combined swept-serrated geometries provide the most favorable noise–performance trade-off, with a predicted reduction of up to 4.8 dB(A) relative to the baseline at the design condition, while maintaining thrust and figure of merit within practical engineering margins. The proposed framework provides a transferable computational basis for the systematic design of low-noise propellers for surveillance UAVs, commercial multirotors, and emerging urban air mobility applications.

27 July 2026 in Applied Mechanics
Verified
Journal Article
Open access
PDF file
MSMaria de la Luz Suarez-Hernandez
Maria de la Luz Suarez-Hernandez
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
Francisco Gallegos-FunesFrancisco Gallegos-Funes
Francisco Gallegos-Funes
FCFrancisco Carrasco-Hernández
Francisco Carrasco-Hernández
JHJONATAN MIRELES HERNÁNDEZ
JONATAN MIRELES HERNÁNDEZ
The soft Bankart lesion is characterized by the abnormal translation of the humeral head during dislocation, which places excessive stress on the labrum and causes it to stretch along with other structures that provide joint stability. This lesion is described as a purely soft tissue injury and occurs due to the detachment of the anteroinferior labroligamentous complex. This research aimed to evaluate the computational biomechanics of a biomodel of the shoulder joint with a soft Bankart lesion during pure abduction using the Finite Element Method (FEM). It evaluates the tissue mechanics of the structures with the lesion, such as ligaments, the articular capsule, and the labrum, which guide and limit the bones of the joint during movement. A healthy shoulder joint biomodel is developed for comparison. The results of stress and strain in the healthy shoulder and the soft Bankart biomodel are analyzed. The results for the soft Bankart biomodel show an increase in stress on the MGHL, with the pIGHL assuming a primary stabilizing role. The CHL and articular capsule limit the excessive displacement of the humeral head.

10 June 2025
Verified
Book Chapter
Closed access
PDF file
JGJonathan Rodolfo Guereca-Ibarra
Jonathan Rodolfo Guereca-Ibarra
GMGuadalupe Murillo-Aleman
Guadalupe Murillo-Aleman
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
JNJorge Alberto Gomez Niebla
Jorge Alberto Gomez Niebla
IZIván Alejandro López Zumarán
Iván Alejandro López Zumarán

17 February 2026
Verified
Book Chapter
Closed access
PDF file
JNJorge Alberto Gomez Niebla
Jorge Alberto Gomez Niebla
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
JGJonathan Rodolfo Guereca-Ibarra
Jonathan Rodolfo Guereca-Ibarra
SBSantiago Barrañón-Salmón
Santiago Barrañón-Salmón
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon