Jose Antonio Vilchez Membrilla

Mr. Jose Antonio Vilchez Membrilla

University of Cádiz, Cádiz, Andalusia, Spain
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2023 in IEEE Access
Verified
Journal Article
Open access
JMJose Antonio Vilchez Membrilla
Jose Antonio Vilchez Membrilla
MPMario F. Pantoja
Mario F. Pantoja
Ana Pilar Valerga PuertaAna Pilar Valerga Puerta
Ana Pilar Valerga Puerta
Victor SouzaVictor Souza
Victor Souza
CSClemente Cobos Sanchez
Clemente Cobos Sanchez
This work presents a framework to develop optimal coils of arbitrary geometry for deep transcranial magnetic stimulation (dTMS). It has been based on a continuous current density inverse boundary element method to generate dTMS coils with depth control and minimum power dissipation. Novel coil geometries that readily adapted to human head have been studied to provide focal stimulation in areas on both prefrontal cortex and right temporal lobe. The designed dTMS coils performance has been numerically validated in a realistic human head model, and prototypes have been built for experimental evaluation. The numerical simulations indicate that the proposed dTMS coils focally stimulate the prescribed brain regions with the desired target depth. The calculated metrics demonstrate that the presented designs outperform existing dTMS coils (the stimulation depth can be increased more than 15%compared to conventional dTMS coils with similar focality). Continuous current density IBEM can be used to develop novel dTMS coils with improved properties for a wide range of geometries. The proposed design method opens up a possibility for exploring new coil solutions based on complex shapes to focally deliver a desired stimulation dose to relatively deep brain targets, which might allow novel and more effective brain stimulation protocols.

12 April 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
CSClemente Cobos Sanchez
Clemente Cobos Sanchez
JMJose Antonio Vilchez Membrilla
Jose Antonio Vilchez Membrilla
ACAlmudena Campos-Jiménez
Almudena Campos-Jiménez
Francisco Javier Garcia-PachecoFrancisco Javier Garcia-Pacheco
Francisco Javier Garcia-Pacheco
This manuscript determines the set of Pareto optimal solutions of certain multiobjective-optimization problems involving continuous linear operators defined on Banach spaces and Hilbert spaces. These multioptimization problems typically arise in engineering. In order to accomplish our goals, we first characterize, in an abstract setting, the set of Pareto optimal solutions of any multiobjective optimization problem. We then provide sufficient topological conditions to ensure the existence of Pareto optimal solutions. Next, we determine the Pareto optimal solutions of convex max–min problems involving continuous linear operators defined on Banach spaces. We prove that the set of Pareto optimal solutions of a convex max–min of form max∥T(x)∥, min∥x∥ coincides with the set of multiples of supporting vectors of T. Lastly, we apply this result to convex max–min problems in the Hilbert space setting, which also applies to convex max–min problems that arise in the design of truly optimal coils in engineering.

26 April 2022 in Mathematics
Verified
Journal Article
Open access
PDF file
ACAlmudena Campos-Jiménez
Almudena Campos-Jiménez
JMJose Antonio Vilchez Membrilla
Jose Antonio Vilchez Membrilla
CSClemente Cobos Sanchez
Clemente Cobos Sanchez
Francisco Javier Garcia-PachecoFrancisco Javier Garcia-Pacheco
Francisco Javier Garcia-Pacheco
For G∈Rm×n and g∈Rm, the minimization min∥Gψ−g∥2, with ψ∈Rn, is known as the Tykhonov regularization. We transport the Tykhonov regularization to an infinite-dimensional setting, that is min∥T(h)−k∥, where T:H→K is a continuous linear operator between Hilbert spaces H,K and h∈H,k∈K. In order to avoid an unbounded set of solutions for the Tykhonov regularization, we transform the infinite-dimensional Tykhonov regularization into a multiobjective optimization problem: min∥T(h)−k∥andmin∥h∥. We call it bounded Tykhonov regularization. A Pareto-optimal solution of the bounded Tykhonov regularization is found. Finally, the bounded Tykhonov regularization is modified to introduce the precise Tykhonov regularization: min∥T(h)−k∥with∥h∥=α. The precise Tykhonov regularization is also optimally solved. All of these mathematical solutions are optimal for the design of Magnetic Resonance Imaging (MRI) coils.

14 August 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
MKMaria A Koponen
Maria A Koponen
JKJuuso T Korhonen
Juuso T Korhonen
JMJose Antonio Vilchez Membrilla
Jose Antonio Vilchez Membrilla
HSHeikki Sinisalo
Heikki Sinisalo
JPJaakko Paasonen
Jaakko Paasonen
Victor SouzaVictor Souza
Victor Souza
Transcranial magnetic stimulation (TMS) is a non-invasive method for stimulating the cortex. Concurrent functional magnetic resonance imaging can show changes in TMS-induced activity in the whole brain, with the potential to inform brain function research and to guide the development of TMS therapy. However, the interaction of the strong current pulses in the TMS coil in the static main magnetic field of the MRI produces high Lorentz forces, which may damage the coil enclosure and compromise the patient’s safety. We studied the time-dependent mechanical behavior and durability of two multi-locus TMS (mTMS) coil arrays inside a high-field MRI bore with finite element modeling. In addition, coil arrays were built and tested based on the simulation results. We found that the current pulses produce shock waves and time-dependent stress distribution in the coil plates. The intensity and location of the maximum stress depend on the current waveform, the coil combination, and the transducer orientation relative to the MRI magnetic field. We found that 30% glass-fiber-filled polyamide is the most durable material out of the six options studied. In addition, novel insights for more durable TMS coil designs were obtained. Our study contributes to a comprehensive understanding of the underlying mechanisms responsible for the structural failure of mTMS coil arrays during stimulation within high static magnetic fields. This knowledge is essential for developing mechanically stable and safe mTMS-MRI transducers.

28 October 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JMJose Antonio Vilchez Membrilla
Jose Antonio Vilchez Membrilla
Ignacio MateosIgnacio Mateos
Ignacio Mateos
ÁQÁngel Quirós-Olozábal
Ángel Quirós-Olozábal
MPMario F. Pantoja
Mario F. Pantoja
CSClemente Cobos Sanchez
Clemente Cobos Sanchez
Here a minimum power dissipation coil transducer has been designed to allow in-flight noise characterization of a low-frequency magnetic measurement system. The coil was produced using PCB technology to provide mechanical stability and easy integration close to the magnetic sensors. The transducer design strategy relies on an inverse boundary element method, which has been efficiently adapted to produce optimal multilayer PCB coils subjected to different geometrical and performance constraints. The resulting coil transducer was simulated and experimentally validated under realistic conditions where the payload is magnetically shielded from low-frequency fluctuations by using a three-layer cylindrical mu-metal enclosure. The results show that the specific transducer coil proposed efficiently produces stable magnetic conditions for adequate validation of the magnetic diagnostic system while providing reduced power dissipation and optimal mechanical stability.

27 June 2024 in Symmetry
Verified
Journal Article
Open access
PDF file
JMJose Antonio Vilchez Membrilla
Jose Antonio Vilchez Membrilla
VSVíctor Salas-Moreno
Víctor Salas-Moreno
Soledad Moreno-PulidoSoledad Moreno-Pulido
Soledad Moreno-Pulido
AAAlberto Sánchez Alzola
Alberto Sánchez Alzola
CSClemente Cobos Sanchez
Clemente Cobos Sanchez
Francisco Javier Garcia-PachecoFrancisco Javier Garcia-Pacheco
Francisco Javier Garcia-Pacheco
Minimum norm problems consist of finding the distance of a closed subset of a normed space to the origin. Usually, the given closed subset is also asked to be convex, thus resulting in a convex minimum norm problem. There are plenty of techniques and algorithms to compute the distance of a closed convex set to the origin, which mostly exist in the Hilbert space setting. In this manuscript, we consider nonconvex minimum norm problems that arise from Bioengineering and reformulate them in such a way that the solution to their reformulation is already known. In particular, we tackle the problem of min∥x∥ subject to ∥Rk(x)∥ ≥ ak for k = 1,…,l, where x∈X and Rk:X→Y are continuous linear operators between real normed spaces X,Y, and ak > 0 for k = 1,…,l. Notice that the region of constraints of the previous problem is neither convex nor balanced. However, it is additively symmetric, which is also the case for the objective function, due to the properties satisfied by norms, which makes possible the analytic resolution of such a nonconvex minimization. The recent literature shows that the design of optimal coils for electronics applications can be achieved by solving problems like this. However, in this work, we apply our analytical solutions to design an optimal coil for an electromagnetic sensor.