José M. Benjumea

Prof. José M. Benjumea

School of Civil Engineering, Industrial University of Santander, Bucaramanga, Santander, Colombia
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 January 2020 in DYNA
Verified
Journal Article
Open access
PDF file
José M. BenjumeaJosé M. Benjumea
José M. Benjumea
MSMehdi Saiidi
Mehdi Saiidi
AIAhmad Itani
Ahmad Itani
A large-scale, two-span bridge model constructed by assembling precast elements was tested under a series of bi-axial ground motionssimulated on a shake table at the Earthquake Engineering Laboratory at the University of Nevada, Reno. The response of the bridge wasestimated before the tests using a three-dimensional computational model developed in OpenSees software. After the tests, key measuredseismic responses were compared to those predicted by the computational model to assess the modeling assumptions. Relatively largeerrors for the displacements, base shears, and hysteretic response of the bridge were observed. The influence of the earthquake loading,materials, connectivity of the precast elements, and boundary conditions in the computational model on the errors are discussed in thispaper. Future modeling directions are proposed to reduce these errors.


1 January 2010 in Revista ingeniería de construcción
Verified
Journal Article
Open access
PDF file
José M. BenjumeaJosé M. Benjumea
José M. Benjumea
GCGustavo Chio
Gustavo Chio
EMEsperanza Maldonado
Esperanza Maldonado

9 December 2021 in Bridge Structures
Verified
Journal Article
Closed access
PDF file
HBHomer Buelvas
Homer Buelvas
José M. BenjumeaJosé M. Benjumea
José M. Benjumea
GCGustavo Chio
Gustavo Chio
The rupture of a cable in cable-supported bridges is an accidental condition that should be considered during the design phase due the impact that this situation could have on the structural safety of the bridge and users. For that reason, design guidelines suggest carrying out a pseudo-static analysis where the failing cable is replaced by a load of the same magnitude as the pre-rupture tension but applied in the opposite direction and multiplied by a dynamic amplification factor (DAF) between 1.5 and 2.0. Previous studies in cable-stayed bridges have shown that the pseudo-static approach may not be suitable. Due to the wide use of extradosed bridges in infrastructure projects around the world, a computational analysis was performed in this investigation to estimate the dynamic amplification factors of extradosed bridge girders and cables when sudden failure of an extradosed cable occurs. The main goal of the study is to determine whether the pseudo-static approach suggested in the guidelines is acceptable. Linear response history analyses were performed by using computational models of extradosed bridges in which the girder stiffness and the suspension (lateral or central) and cable layout (fan or harp) of the cables were modified. From the analysis, the DAFs were calculated and compared to those recommended in the design guidelines. The calculated DAFs for the axial forces and bending moment in the girder of the bridges and for the axial forces in the extradosed cables were smaller than 2.0. However, in some cases the DAF for shear forces were higher than 2.0, especially when the girder stiffness was relatively low. The results indicate that the recommendations of the design guidelines are adequate for extradosed bridges, which is a result of the relatively high stiffness of the girder and low inclination of extradosed cables. Despite this, response history analyses like the one performed in this study are recommended to assess the response of the bridge under cable breakage.

1 August 2021 in Journal of Bridge Engineering
Verified
Journal Article
Closed access
PDF file
José M. BenjumeaJosé M. Benjumea
José M. Benjumea
MSM. “Saiid” Saiidi
M. “Saiid” Saiidi
AIAhmad Itani
Ahmad Itani
A prerequisite to the implementation of accelerated bridge construction (ABC) in moderate and high seismic regions is reliable data proving that bridges constructed by assembling precast elements can emulate the seismic performance of cast-in-place bridges. Previous seismic studies have not provided sufficient information about the interaction of conventionally reinforced precast concrete elements and connections when they are integrated within a bridge system. This paper addresses this knowledge gap by conducting biaxial shake table tests on a 0.35-scale, two-span bridge model that incorporated 38 precast reinforced and prestressed concrete elements. The elements were joined by using six connection types joining column to footing, column to cap beam, girder to cap beam, deck panels (two types), and deck to girder. The bridge and the connections performed well even under earthquake motions beyond the design-level earthquake and combined large drift ratio demands and substantial in-plane rotation. Although the load path was affected by the interaction among different components, no adverse effect was observed.