Julien FLEURET

Mr. Julien FLEURET

Université Laval
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2019 in Animals
Verified
Journal Article
Open access
PDF file
LRLuiene Moura Rocha
Luiene Moura Rocha
NDNicolas Devillers
Nicolas Devillers
Xavier MaldagueXavier Maldague
Xavier Maldague
FKFidèle Z. Kabemba
Fidèle Z. Kabemba
JFJulien FLEURET
Julien FLEURET
Luigi FaucitanoLuigi Faucitano
Luigi Faucitano
This study aimed at validating the anatomical sites for the measurement of infrared (IR) body surface temperature as a tool to monitor the pigs’ response to handling and transport stress. The selected anatomical sites were the neck (infrared neck temperature—IRNT), rump (infrared rump temperature—IRRT), orbital (infrared orbital temperature—IROT) and behind ears (infrared behind ears temperature—IRBET) regions. A total of 120 pigs were handled from the finishing pen to the loading dock through a handling test course. Two handling types (gentle vs. rough) and number of laps (1 vs. 3) were applied according to a 2 × 2 factorial design. After loading, pigs were transported for 40 min and returned to their home pens. Animal behavior, heart rate, rectal temperature and salivary cortisol concentration were measured for validation. Increased IR body temperature, heart rate and salivary cortisol levels were observed in response to rough handling and longer distance walk (P < 0.05 for all). The greatest correlations were found between IROT and IRBET temperatures and salivary cortisol concentration at the end of the handling test (r = 0.49 and r = 0.50, respectively; P < 0.001 for both). Therefore, IR pig’s head surface temperature may be useful for a comprehensive assessment of the physiological response to handling and transport stress.

12 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JFJulien FLEURET
Julien FLEURET
Samira EbrahimiSamira Ebrahimi
Samira Ebrahimi
Clemente Ibarra-CastanedoClemente Ibarra-Castanedo
Clemente Ibarra-Castanedo
Xavier MaldagueXavier Maldague
Xavier Maldague
Dimensional reduction methods have significantly improved the simplification of Pulsed Thermography (PT) data while improving the accuracy of the results. Such approaches reduce the quantity of data to analyze and improve the contrast of the main defects in the samples contributed to their popularity. Many works have been proposed in the literature mainly based on improving the Principal Component Thermography (PCT). Recently the Independent Component Analysis (ICA) has been a topic of attention. Many different approaches have been proposed in the literature to solve the ICA. In this paper, we investigated several recent ICA methods and evaluated their influence on PT data compared with the state-of-the-art methods. We conducted our evaluation on reference CFRP samples with known defects. We found that ICA outperform PCT for small and deep defects. For other defects ICA results are often not far from the results obtained by PCT. However, the frequency of acquisition and the ICA methods have a great influence on the results.

10 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Samira EbrahimiSamira Ebrahimi
Samira Ebrahimi
JFJulien FLEURET
Julien FLEURET
MKMatt Klein
Matt Klein
Louis-Daniel ThérouxLouis-Daniel Théroux
Louis-Daniel Théroux
MGMarc Georges
Marc Georges
Xavier MaldagueXavier Maldague
Xavier Maldague
Pulsed Thermography (PT) data are usually affected by noise and as such most of the research effort in the last few years has been directed towards the development of advanced signal processing methods to improve defect detection. Among the numerous techniques that have been proposed, principal component thermography (PCT)—based on principal component analysis (PCA)—is one of the most effective in terms of defect contrast enhancement and data compression. However, it is well-known that PCA can be significantly affected in the presence of corrupted data (e.g., noise and outliers). Robust PCA (RPCA) has been recently proposed as an alternative statistical method that handles noisy data more properly by decomposing the input data into a low-rank matrix and a sparse matrix. We propose to process PT data by RPCA instead of PCA in order to improve defect detectability. The performance of the resulting approach, Robust Principal Component Thermography (RPCT)—based on RPCA, was evaluated with respect to PCT—based on PCA, using a CFRP sample containing artificially produced defects. We compared results quantitatively based on two metrics, Contrast-to-Noise Ratio (CNR), for defect detection capabilities, and the Jaccard similarity coefficient, for defect segmentation potential. CNR results were on average 40% higher for RPCT than for PCT, and the Jaccard index was slightly higher for RPCT (0.7395) than for PCT (0.7010). In terms of computational time, however, PCT was 11.5 times faster than RPCT. Further investigations are needed to assess RPCT performance on a wider range of materials and to optimize computational time.

7 February 2022 in Quantitative InfraRed Thermography Journal
Verified
Journal Article
Closed access
JFJulien FLEURET
Julien FLEURET
SES. Ebrahimi
S. Ebrahimi
Clemente Ibarra-CastanedoClemente Ibarra-Castanedo
Clemente Ibarra-Castanedo
XMX. Maldague
X. Maldague
This study introduces and evaluates a new approach to reconstruct image sequences acquired during non-destructive testing by pulsed thermography. The proposed method consists of applying two linear support vector regressions to model the evolution of the data from both a spatial and temporal point of view. Each regression vectors will map the data with the number of pixels and the number of frames using convex optimisation. Then the regression vectors are used to predict a more robust representation of the data, thus reconstructing the sequence. The proposed method has been applied to data related to a reference sample of carbon reinforced fibre with known defects. This approach was evaluated on a sequence with severe non-uniform heating and was compared with state-of-the-art methods. Despite being sensitive to non-uniform heating, the proposed method provided a higher CNR score on smaller defects, compared with state-of-the-art methods. For the shallowest defects it shows better performance in term of contrast reconstruction compared to partial least-squares thermography (PLST). It also outperforms principal component thermography (PCT), and thermographic signal reconstruction-PCT (TSR-PCT) for defects located at a depth of 0.6 mm and 0.8 mm below the surface.

29 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Samira EbrahimiSamira Ebrahimi
Samira Ebrahimi
JFJulien FLEURET
Julien FLEURET
MKMatt Klein
Matt Klein
LTLouis-Daniel Théroux
Louis-Daniel Théroux
Clemente Ibarra-CastanedoClemente Ibarra-Castanedo
Clemente Ibarra-Castanedo
Xavier MaldagueXavier Maldague
Xavier Maldague
Pulsed thermography is a commonly used non-destructive testing method and is increasingly studied for the assessment of advanced materials such as carbon fibre-reinforced polymer (CFRP). Different processing approaches are proposed to detect and characterize anomalies that may be generated in structures during the manufacturing cycle or service period. In this study, matrix decomposition using Robust PCA via Inexact-ALM is investigated as a pre- and post-processing approach in combination with state-of-the-art approaches (i.e., PCT, PPT and PLST) on pulsed thermography thermal data. An academic sample with several artificial defects of different types, i.e., flat-bottom-holes (FBH), pull-outs (PO) and Teflon inserts (TEF), was employed to assess and compare defect detection and segmentation capabilities of different processing approaches. For this purpose, the contrast-to-noise ratio (CNR) and similarity coefficient were used as quantitative metrics. The results show a clear improvement in CNR when Robust PCA is applied as a pre-processing technique, CNR values for FBH, PO and TEF improve up to 164%, 237% and 80%, respectively, when compared to principal component thermography (PCT), whilst the CNR improvement with respect to pulsed phase thermography (PPT) was 77%, 101% and 289%, respectively. In the case of partial least squares thermography, Robust PCA results improved not only only when used as a pre-processing technique but also when used as a post-processing technique; however, this improvement is higher for FBHs and POs after pre-processing. Pre-processing increases CNR scores for FBHs and POs with a ratio from 0.43% to 115.88% and from 13.48% to 216.63%, respectively. Similarly, post-processing enhances the FBHs and POs results with a ratio between 9.62% and 296.9% and 16.98% to 92.6%, respectively. A low-rank matrix computed from Robust PCA as a pre-processing technique on raw data before using PCT and PPT can enhance the results of 67% of the defects. Using low-rank matrix decomposition from Robust PCA as a pre- and post-processing technique outperforms PLST results of 69% and 67% of the defects. These results clearly indicate that pre-processing pulsed thermography data by Robust PCA can elevate the defect detectability of advanced processing techniques, such as PCT, PPT and PLST, while post-processing using the same methods, in some cases, can deteriorate the results.

12 May 2022 in Quantitative InfraRed Thermography Journal
Verified
Journal Article
Closed access
JFJulien FLEURET
Julien FLEURET
Samira EbrahimiSamira Ebrahimi
Samira Ebrahimi
Clemente Ibarra-CastanedoClemente Ibarra-Castanedo
Clemente Ibarra-Castanedo
Xavier MaldagueXavier Maldague
Xavier Maldague
This paper explores the application of Blind Image Quality Assessment (BIQA) metrics to pulsed thermography. Two BIQA were used to subsample a sequence of images acquired using Pulse Thermography (PT). The experiments show that the sequences subsampled using BIQA significantly improve the results when applied to metallic samples but fail to capture informative features on composite materials. On metallic samples, when the PCT is applied, an average improvement of 139% of the Contrast to Noise Ratio (CNR) score is observed, on the sequences subsampled, compared with the entire sequence. Nonetheless, the CNR shows that processing the entire data sequence offers 240% improvement compared with subsampled sequences on composite materials.