Matt Klein

Mr. Matt Klein

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2018 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
Ruben UsamentiagaRuben Usamentiaga
Ruben Usamentiaga
YMYacine Mokhtari
Yacine Mokhtari
Clemente Ibarra-CastanedoClemente Ibarra-Castanedo
Clemente Ibarra-Castanedo
MKMatt Klein
Matt Klein
Marc GenestMarc Genest
Marc Genest
Xavier MaldagueXavier Maldague
Xavier Maldague
Active thermography is a proven technology used in a wide variety of applications. In the most common approach using a static configuration, the elements involved in the inspection do not move. This presents serious drawbacks when it is applied to the inspection of large products and machines. An alternative approach is the dynamic inspection, which enables the inspection of large and complex products with better resolution, but it is also extremely challenging as data reconstruction is necessary. This work analyzes two methods for dynamic inspection using active infrared thermography: the thermal photocopier and the line scan. Automatic robust methods are proposed to calculate the temperature-time history, producing a pseudo-static sequence that can be further processed using advanced data processing algorithms to improve defect detection. Results demonstrate the robustness of the proposed methods and the ability to inspect large products with excellent results.

10 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Samira EbrahimiSamira Ebrahimi
Samira Ebrahimi
JFJulien FLEURET
Julien FLEURET
MKMatt Klein
Matt Klein
Louis-Daniel ThérouxLouis-Daniel Théroux
Louis-Daniel Théroux
MGMarc Georges
Marc Georges
Xavier MaldagueXavier Maldague
Xavier Maldague
Pulsed Thermography (PT) data are usually affected by noise and as such most of the research effort in the last few years has been directed towards the development of advanced signal processing methods to improve defect detection. Among the numerous techniques that have been proposed, principal component thermography (PCT)—based on principal component analysis (PCA)—is one of the most effective in terms of defect contrast enhancement and data compression. However, it is well-known that PCA can be significantly affected in the presence of corrupted data (e.g., noise and outliers). Robust PCA (RPCA) has been recently proposed as an alternative statistical method that handles noisy data more properly by decomposing the input data into a low-rank matrix and a sparse matrix. We propose to process PT data by RPCA instead of PCA in order to improve defect detectability. The performance of the resulting approach, Robust Principal Component Thermography (RPCT)—based on RPCA, was evaluated with respect to PCT—based on PCA, using a CFRP sample containing artificially produced defects. We compared results quantitatively based on two metrics, Contrast-to-Noise Ratio (CNR), for defect detection capabilities, and the Jaccard similarity coefficient, for defect segmentation potential. CNR results were on average 40% higher for RPCT than for PCT, and the Jaccard index was slightly higher for RPCT (0.7395) than for PCT (0.7010). In terms of computational time, however, PCT was 11.5 times faster than RPCT. Further investigations are needed to assess RPCT performance on a wider range of materials and to optimize computational time.

17 May 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Clemente Ibarra-CastanedoClemente Ibarra-Castanedo
Clemente Ibarra-Castanedo
PSPierre Servais
Pierre Servais
MKMatt Klein
Matt Klein
TBThibault Boulanger
Thibault Boulanger
AKAlain Kinard
Alain Kinard
Xavier MaldagueXavier Maldague
Xavier Maldague
Nondestructive testing (NDT) of composite materials is of paramount importance to the aerospace industry. Several NDT methods have been adopted for the inspection of components during production and all through the aircraft service life, with infrared thermography (IRT) techniques, such as line scan thermography (LST) and pulsed thermography (PT), gaining popularity thanks to their rapidity and versatility. On one hand, LST is an attractive solution for the fast inspection of large and complex geometry composite parts during production. On the other hand, PT can be employed for the characterization of composite materials, e.g., the determination of thermal diffusivity and defect depth estimation. In this study, the use of LST with an uncooled microbolometer camera is explored for the identification of artificially produced porosity and barely visible impact damage (BVID) on academic samples. The performance of LST is quantitatively assessed with respect to PT (considered the gold standard in this case) using a high-definition cooled camera through the contrast-to-noise ratio (CNR) criterium. It is concluded that, although in most cases the measured CNR values were higher for PT than for LST (as expected since a high-definition camera and longer acquisition times were used), the majority of the defects were clearly detected (CNR ≥ 2.5) by LST without the need of advanced signal processing, proving the suitability of LST for the inspection of aerospace composite components. Furthermore, the deepest defect investigated herein (z ≈ 3 mm) was detected solely by LST combined with signal processing and spatial filtering (CNR = 3.6) and not by PT (since pulse heating was not long enough for this depth). In addition, PT was used for the determination of the thermal diffusivity of all samples and the subsequent depth estimation of porosity and damaged areas by pulsed phase thermography (PPT).

20 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
Ruben UsamentiagaRuben Usamentiaga
Ruben Usamentiaga
Clemente Ibarra-CastanedoClemente Ibarra-Castanedo
Clemente Ibarra-Castanedo
MKMatt Klein
Matt Klein
Xavier MaldagueXavier Maldague
Xavier Maldague
JPJeroen Peeters
Jeroen Peeters
ASAlvaro Sanchez-Beato
Alvaro Sanchez-Beato
Bicycle frames made of carbon fibre are extremely popular for high-performance cycling due to the stiffness-to-weight ratio, which enables greater power transfer. However, products manufactured using carbon fibre are sensitive to impact damage. Therefore, intelligent nondestructive evaluation is a required step to prevent failures and ensure a secure usage of the bicycle. This work proposes an inspection method based on active thermography, a proven technique successfully applied to other materials. Different configurations for the inspection are tested, including power and heating time. Moreover, experiments are applied to a real bicycle frame with generated impact damage of different energies. Tests show excellent results, detecting the generated damage during the inspection. When the results are combined with advanced image post-processing methods, the SNR is greatly increased, and the size and localization of the defects are clearly visible in the images.

7 November 2019 in Electronics
Verified
Journal Article
Open access
PDF file
Bardia YousefiBardia Yousefi
Bardia Yousefi
HSHossein Memarzadeh Sharifipour
Hossein Memarzadeh Sharifipour
MEMana Eskandari
Mana Eskandari
Clemente Ibarra-CastanedoClemente Ibarra-Castanedo
Clemente Ibarra-Castanedo
DLDenis Laurendeau
Denis Laurendeau
Xavier MaldagueXavier Maldague
Xavier Maldague
Thermal imagery for monitoring of body temperature provides a powerful tool to decrease health risks (e.g., burning) for patients during medical imaging (e.g., magnetic resonance imaging). The presented approach discusses an experiment to simulate radiology conditions with infrared imaging along with an automatic thermal monitoring/tracking system. The thermal tracking system uses an incremental low-rank noise reduction applying incremental singular value decomposition (SVD) and applies color based clustering for initialization of the region of interest (ROI) boundary. Then a particle filter tracks the ROI(s) from the entire thermal stream (video sequence). The thermal database contains 15 subjects in two positions (i.e., sitting, and lying) in front of thermal camera. This dataset is created to verify the robustness of our method with respect to motion-artifacts and in presence of additive noise (2–20%—salt and pepper noise). The proposed approach was tested for the infrared images in the dataset and was able to successfully measure and track the ROI continuously (100% detecting and tracking the temperature of participants), and provided considerable robustness against noise (unchanged accuracy even in 20% additive noise), which shows promising performance.

29 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Samira EbrahimiSamira Ebrahimi
Samira Ebrahimi
JFJulien FLEURET
Julien FLEURET
MKMatt Klein
Matt Klein
LTLouis-Daniel Théroux
Louis-Daniel Théroux
Clemente Ibarra-CastanedoClemente Ibarra-Castanedo
Clemente Ibarra-Castanedo
Xavier MaldagueXavier Maldague
Xavier Maldague
Pulsed thermography is a commonly used non-destructive testing method and is increasingly studied for the assessment of advanced materials such as carbon fibre-reinforced polymer (CFRP). Different processing approaches are proposed to detect and characterize anomalies that may be generated in structures during the manufacturing cycle or service period. In this study, matrix decomposition using Robust PCA via Inexact-ALM is investigated as a pre- and post-processing approach in combination with state-of-the-art approaches (i.e., PCT, PPT and PLST) on pulsed thermography thermal data. An academic sample with several artificial defects of different types, i.e., flat-bottom-holes (FBH), pull-outs (PO) and Teflon inserts (TEF), was employed to assess and compare defect detection and segmentation capabilities of different processing approaches. For this purpose, the contrast-to-noise ratio (CNR) and similarity coefficient were used as quantitative metrics. The results show a clear improvement in CNR when Robust PCA is applied as a pre-processing technique, CNR values for FBH, PO and TEF improve up to 164%, 237% and 80%, respectively, when compared to principal component thermography (PCT), whilst the CNR improvement with respect to pulsed phase thermography (PPT) was 77%, 101% and 289%, respectively. In the case of partial least squares thermography, Robust PCA results improved not only only when used as a pre-processing technique but also when used as a post-processing technique; however, this improvement is higher for FBHs and POs after pre-processing. Pre-processing increases CNR scores for FBHs and POs with a ratio from 0.43% to 115.88% and from 13.48% to 216.63%, respectively. Similarly, post-processing enhances the FBHs and POs results with a ratio between 9.62% and 296.9% and 16.98% to 92.6%, respectively. A low-rank matrix computed from Robust PCA as a pre-processing technique on raw data before using PCT and PPT can enhance the results of 67% of the defects. Using low-rank matrix decomposition from Robust PCA as a pre- and post-processing technique outperforms PLST results of 69% and 67% of the defects. These results clearly indicate that pre-processing pulsed thermography data by Robust PCA can elevate the defect detectability of advanced processing techniques, such as PCT, PPT and PLST, while post-processing using the same methods, in some cases, can deteriorate the results.