Jyothi Sri Vadlamudi

Dr. Jyothi Sri Vadlamudi

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2025 in Computers and Electrical Engineering
Verified
Journal Article
Closed access
VijayaKumar VelpulaVijayaKumar Velpula
VijayaKumar Velpula
Jyothi Sri VadlamudiJyothi Sri Vadlamudi
Jyothi Sri Vadlamudi
Malathi JanapatiMalathi Janapati
Malathi Janapati
PKPurna Prakash Kasaraneni
Purna Prakash Kasaraneni
Yellapragada Venkata Pavan KumarYellapragada Venkata Pavan Kumar
Yellapragada Venkata Pavan Kumar
Rammohan MallipeddiRammohan Mallipeddi
Rammohan Mallipeddi

12 May 2025 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
VijayaKumar VelpulaVijayaKumar Velpula
VijayaKumar Velpula
KRKamireddy Rasool Reddy
Kamireddy Rasool Reddy
KPK. Naga Prakash
K. Naga Prakash
KJK. Prasanthi Jasmine
K. Prasanthi Jasmine
Jyothi Sri VadlamudiJyothi Sri Vadlamudi
Jyothi Sri Vadlamudi
Brain tumors significantly impact global health and pose serious challenges for accurate diagnosis due to their diverse nature and complex characteristics. Effective diagnosis and classification are essential for selecting the best treatment strategies and forecasting patient outcomes. Currently, histopathological examination of biopsy samples is the standard method for brain tumor identification and classification. However, this method is invasive, time-consuming, and prone to human error. To address these limitations, a fully automated approach is proposed for brain tumor classification. Recent advancements in deep learning, particularly convolutional neural networks (CNNs), have shown promise in improving the accuracy and efficiency of tumor detection from magnetic resonance imaging (MRI) scans. In response, a model was developed that integrates machine learning (ML) and deep learning (DL) techniques. The process began by splitting the data into training, testing, and validation sets. Images were then resized and cropped to enhance model quality and efficiency. Relevant texture features were extracted using a modified Visual Geometry Group (VGG) architecture. These features were fed into various supervised ML models, including support vector machine (SVM), k-nearest neighbors (KNN), logistic regression (LR), stochastic gradient descent (SGD), random forest (RF), and AdaBoost, with GridSearchCV used for hyperparameter tuning. The model’s performance was evaluated using key metrics such as accuracy, precision, recall, F1-score, and specificity. Experimental results demonstrate that the proposed approach offers a robust and automated solution for brain tumor classification, achieving the highest accuracy of 94.02% with VGG19 and 96.30% with VGG16. This model can significantly assist healthcare professionals in early tumor detection and in improving diagnostic accuracy.

25 November 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
VijayaKumar VelpulaVijayaKumar Velpula
VijayaKumar Velpula
Jyothi Sri VadlamudiJyothi Sri Vadlamudi
Jyothi Sri Vadlamudi
PKPurna Prakash Kasaraneni
Purna Prakash Kasaraneni
Yellapragada Venkata Pavan KumarYellapragada Venkata Pavan Kumar
Yellapragada Venkata Pavan Kumar
Glaucoma, a primary cause of irreversible blindness, necessitates early detection to prevent significant vision loss. In the literature, fundus imaging is identified as a key tool in diagnosing glaucoma, which captures detailed retina images. However, the manual analysis of these images can be time-consuming and subjective. Thus, this paper presents an automated system for glaucoma detection using fundus images, combining diverse feature extraction methods with advanced classifiers, specifically Support Vector Machine (SVM) and AdaBoost. The pre-processing step incorporated image enhancement via Contrast-Limited Adaptive Histogram Equalization (CLAHE) to enhance image quality and feature extraction. This work investigated individual features such as the histogram of oriented gradients (HOG), local binary patterns (LBP), chip histogram features, and the gray-level co-occurrence matrix (GLCM), as well as their various combinations, including HOG + LBP + chip histogram + GLCM, HOG + LBP + chip histogram, and others. These features were utilized with SVM and Adaboost classifiers to improve classification performance. For validation, the ACRIMA dataset, a public fundus image collection comprising 369 glaucoma-affected and 309 normal images, was used in this work, with 80% of the data allocated for training and 20% for testing. The results of the proposed study show that different feature sets yielded varying accuracies with the SVM and Adaboost classifiers. For instance, the combination of LBP + chip histogram achieved the highest accuracy of 99.29% with Adaboost, while the same combination yielded a 65.25% accuracy with SVM. The individual feature LBP alone achieved 97.87% with Adaboost and 98.58% with SVM. Furthermore, the combination of GLCM + LBP provided a 98.58% accuracy with Adaboost and 97.87% with SVM. The results demonstrate that CLAHE and combined feature sets significantly enhance detection accuracy, providing a reliable tool for early and precise glaucoma diagnosis, thus facilitating timely intervention and improved patient outcomes.

26 November 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
Jyothi Sri VadlamudiJyothi Sri Vadlamudi
Jyothi Sri Vadlamudi
SMSAMEEULLA KHAN MD
SAMEEULLA KHAN MD
Gaussian derivatives offer valuable capabilities for analyzing image characteristics such as structure, edges, texture, and features, which are essential aspects in the assessment of image quality. Recently, Convolutional Neural Networks (CNNs) have gained in importance in computer vision applications and also in the image quality assessment domain. Due to the characteristics of Gaussian derivatives that perform a major role in assessing image quality, this work seeks to combine these characteristics with CNNs to better extract features for assessing the quality of an image. While CNNs have demonstrated their ability to handle distortion effectively, they are limited in their capacity to capture features at different scales, making them inadequate in dealing with significant variations in object size. Consequently, the concept of spatial pyramid pooling (SPP) is introduced to address this limitation in image quality assessment (IQA). SPP involves pooling the spatial feature maps from the highest convolutional layers into a feature representation of fixed length. Additionally, through the utilization of a convolutional block attention module (CBAM), a module designed for the interpretation of images, and local importance pooling (LIP), we propose method for no-reference image quality assessment has demonstrated improved accuracy, generalization, and efficiency on the IVC database compared to conventional or traditional IQA methods, while achieving competitive performance on other datasets.

21 April 2026 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
VijayaKumar VelpulaVijayaKumar Velpula
VijayaKumar Velpula
JSJonnala Naga Surekha
Jonnala Naga Surekha
NGNekkanti Gowthami
Nekkanti Gowthami
SAS. Anuradha
S. Anuradha
VMVenkateswara Rao Muvva
Venkateswara Rao Muvva
Jyothi Sri VadlamudiJyothi Sri Vadlamudi
Jyothi Sri Vadlamudi
Glaucoma is an increasing ocular disease and one of the major causes of irreversible blindness globally. Thus, it is of utmost importance to diagnose glaucoma accurately and in a timely manner for appropriate clinical intervention. Retinal fundus image analysis is a non-invasive approach for glaucoma screening. However, it is a tedious and subjective process for accurate glaucoma detection. In this work, a customized convolutional neural network (CNN) model is proposed for glaucoma classification using fundus images, and an attention mechanism is employed for improved discriminative feature learning. Experiments were carried out on two publicly available datasets, namely Drishti-GS1 and ACRIMA, for unbalanced and balanced datasets, respectively. Data augmentation and hyperparameter tuning were employed for improved model generalization. To increase model explainability and trust for accurate glaucoma screening, gradient-weighted class activation mapping (Grad-CAM) is employed for accurate glaucoma screening. For accurate glaucoma screening, the proposed model attained 90.32% and 96.45% accuracy on the Drishti-GS1 and ACRIMA datasets, respectively, with higher sensitivity and AUC scores. Thus, it is evident that the proposed model employing attention mechanisms and explainable AI attained higher accuracy for accurate glaucoma screening.