This study presents the seismic qualification of an Exhaust Gas Silencer (EGS) installed in the Emergency Diesel Generator (EDG) system of a nuclear power plant. Using Finite Element Analysis (FEA) with ANSYS 12.1, the structural performance of the EGS was assessed under normal, upset (½ Safe Shutdown Earthquake), and faulted (Safe Shutdown Earthquake) conditions, in accordance with KEPIC MN Class 3 and ASME Section III standards. Modal analysis confirmed a fundamental natural frequency of 69.13 Hz, exceeding the 33 Hz threshold, thereby validating the use of equivalent static seismic analysis. Locations of analysis which were critical, including saddle supports, head-to-shell junctions and reinforced areas, proved that the maximum combined membrane and bending stresses did not exceed those defined by code. The maximum stress of 240.62 MPa was observed at the reinforced angle, which remained below the permissible stress of 243.12 MPa during faulted seismic loading. These findings justify the structural integrity and seismic resilience of the EGS.By maintaining emission control during seismic events, the qualified EGS ensures safe dispersal of exhaust gases, preventing uncontrolled environmental release and supporting sustainability in nuclear operations.The study also establishes a replicable and code-compliant methodology for qualifying auxiliary components in nuclear systems subjected to seismic loading.
This study presents a comprehensive thermo-structural and modal analysis of a ball screw assembly. Thermal analysis revealed a maximum temperature of 29.1 °C at the ball nut, corresponding to a total rise of 7.1 °C above ambient. The resulting thermal deformation reached 77.81 μm, while the von Mises stress peaked at 53.9 MPa, both within acceptable limits. Modal simulation of 360 modes showed a sharp increase in frequency with mode number and larger deformation patterns at the higher modes. The first two modes dominate the effective mass with the first 8 modes capturing over 90% of the cumulative effective mass. Overall, the results demonstrate stable thermal performance, limited deformation, low stress, and controlled vibrations, confirming the modeling approach and the suitability of 42CrMo4 steel for high-precision ball screw assemblies.