Karola Panke

Dr. Karola Panke

Optometry and Vision Science, University of Latvia, Riga, Rīga, Latvia
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2019
Verified
Conference Paper
Open access
Karola PankeKarola Panke
Karola Panke
Tatjana PladereTatjana Pladere
Tatjana Pladere
MVMara Velina
Mara Velina
ASAiga Svede
Aiga Svede
GIGatis Ikaunieks
Gatis Ikaunieks
GKGunta Krumina
Gunta Krumina

16 October 2019 in Photonics
Verified
Journal Article
Open access
PDF file
Karola PankeKarola Panke
Karola Panke
Tatjana PladereTatjana Pladere
Tatjana Pladere
MVMara Velina
Mara Velina
Aiga SvedeAiga Svede
Aiga Svede
GKGunta Krumina
Gunta Krumina
Volumetric display shows promising implications for healthcare related applications as an innovative technology that creates real three-dimensional (3D) image by illuminating points in three-dimensional space to generate volumetric images without image separation. We used eccentric photorefractometry to objectively study ocular performance in a practical environment by evaluating near work-induced refraction shift, accommodative microfluctuations, and pupil size for 38 young adults after viewing anaglyph, and volumetric 3D content for prolonged time. The results of our study demonstrate that participants who performed relative depth estimation task on volumetric 3D content were less likely to experience task-induced myopic refraction shift. For both 3D content types, we observed pupil constriction, that is possibly related to visual fatigue. For anaglyph 3D pupil constriction, onset was observed significantly sooner, compared to volumetric 3D. Overall, sustained work with 3D content, and small disparities or the fully eliminated possibility of accommodation-vergence conflict, not only minimizes near work-induced myopic shift, but also provide beneficial accommodation relaxation that was demonstrated in this study as hypermetropic shift for nearly half of participants.

20 December 2024 in Vision
Verified
Journal Article
Open access
PDF file
ASAlona Sumarokova
Alona Sumarokova
Reinis AlksnisReinis Alksnis
Reinis Alksnis
DRDagni Räppo
Dagni Räppo
Karola PankeKarola Panke
Karola Panke
GKGunta Krumina
Gunta Krumina
Tatjana PladereTatjana Pladere
Tatjana Pladere
Virtual reality (VR) can challenge the visual system, leading to temporary oculomotor changes, though the degree of change varies among individuals. While the vergence and accommodation system plays a crucial role in VR perception, it remains unclear whether individuals whose visual functions fall outside clinical norms experience larger changes. Thus, our study aimed to investigate whether changes in vergence and accommodation responses following VR gameplay differ between individuals with and without non-strabismic binocular and accommodative disorders. To assess this, both subjective and objective measurements were conducted before and after 20 min of playing Beat Saber. Results revealed significant alterations across both subjective measurements—near point of convergence and near point of accommodation—and objective measurements, including eye refraction, accommodation lag, and accommodative microfluctuations at far. Moreover, individuals with non-strabismic binocular and accommodative disorders exhibited larger accommodative microfluctuations at far compared to the control group. Overall, these findings indicate that considering individual differences in vergence and accommodation responses is important when evaluating the impact of VR on the visual system and can be helpful in the design and use of VR systems, particularly for individuals with binocular and accommodative disorders.

23 June 2024 in Vision
Verified
Journal Article
Open access
PDF file
Aiga SvedeAiga Svede
Aiga Svede
SSSvetlana Semjonova
Svetlana Semjonova
AGAngelina Ganebnaya
Angelina Ganebnaya
LPLiga Puhova
Liga Puhova
KBKulsum Baig
Kulsum Baig
Dmitry GromovDmitry Gromov
Dmitry Gromov
This study aims to explore the potential of a novel EYE ROLL device designed to facilitate guided vision relaxation exercises in an open space. A prospective study was performed on 89 participants who perform screenwork for at least four hours daily. All participants were randomly divided into three groups: a Control group with no exercising, a Manual group undertook manual vision relax ation exercises, and an Eyeroll group engaged in EYE ROLL device-assisted vision relaxation exercises. Each participant underwent three evaluations (an initial baseline assessment, a 4-week follow-up, and an 8-week follow-up) with four assessment tools: a comprehensive vision examination, an in-depth questionnaire, saccadic eye movement recordings, and objective accommodation measurements. There was a statistically significant decrease (35% and above) in complaint scores at the 4-week follow-up in both training groups. Although statistically insignificant, complaints continued to decrease after an 8-week period. No significant changes were observed in clinical or objective accommodative parameters. Some variation of visual functions was observed in all groups due to repeated measures. Vision relaxation exercises combined with proper vision ergonomics and working habits can reduce asthenopic complaints. The EYE ROLL device presents a promising tool for integrating these exercises into the working environment.

22 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
LKLinda Krauze
Linda Krauze
Karola PankeKarola Panke
Karola Panke
GKGunta Krumina
Gunta Krumina
Tatjana PladereTatjana Pladere
Tatjana Pladere
Eccentric photorefractometry is widely used to measure eye refraction, accommodation, gaze position, and pupil size. While the individual calibration of refraction and accommodation data has been extensively studied, gaze measurements have received less attention. PowerRef 3 does not incorporate individual calibration for gaze measurements, resulting in a divergent offset between the measured and expected gaze positions. To address this, we proposed two methods to calculate the physiological vergence angle based on the visual vergence data obtained from PowerRef 3. Twenty-three participants aged 25 ± 4 years viewed Maltese cross stimuli at distances of 25, 30, 50, 70, and 600 cm. The expected vergence angles were calculated considering the individual interpupillary distance at far. Our results demonstrate that the PowerRef 3 gaze data deviated from the expected vergence angles by 9.64 ± 2.73° at 25 cm and 9.25 ± 3.52° at 6 m. The kappa angle calibration method reduced the discrepancy to 3.93 ± 1.19° at 25 cm and 3.70 ± 0.36° at 600 cm, whereas the linear regression method further improved the accuracy to 3.30 ± 0.86° at 25 cm and 0.26 ± 0.01° at 600 cm. Both methods improved the gaze results, with the linear regression calibration method showing greater overall accuracy.

30 August 2024 in Vision
Verified
Journal Article
Open access
PDF file
Karola PankeKarola Panke
Karola Panke
MBMegija Bambane
Megija Bambane
This study aimed to evaluate the clinical information revealed after cycloplegia and assess how age and non-cycloplegic refractive status influence the classification of types of refractive error, as well as the relationship between age and cycloplegia-induced changes in the power of refractive errors. We analysed the records of 472 non-population-based ophthalmology practice patients aged 3–28 years (mean ± SD: 9.1 ± 4.6). Cycloplegia was induced with one drop of cyclopentolate 1% in each eye, and eye refraction was measured 30 ± 5 min later using an objective autorefractometer. Cycloplegia induced a clinically significant (≥0.50 D) hyperopic shift in the spherical equivalent of 60.2% of participants and a myopic shift in 1%, resulting in a 34.1% increase in the frequency of participants with hyperopia, while the frequency of those with myopia and emmetropia decreased by 5.5% and 23.3%, respectively. The average spherical equivalent difference (mean ± SD) induced by cycloplegia was 0.72 ± 0.73 D, with the highest difference observed in the 3–5 years age group (1.18 ± 0.85 D). The differences in astigmatism power (p = 0.84) and astigmatism axis (p = 0.97) between non-cycloplegic and cycloplegic conditions were not statistically significant.