Karthik Silaipillayarputhur

Dr. Karthik Silaipillayarputhur

King Faisal University, Al-Ahsa 31982, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2017 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
KSKarthik Silaipillayarputhur
Karthik Silaipillayarputhur
TMTawfiq Al Mughanam
Tawfiq Al Mughanam
AMAbdulaziz Al Mojil
Abdulaziz Al Mojil
MDMohammed Al Dhmoush
Mohammed Al Dhmoush
This paper considers an analytical and a numerical approach in the design of a concentric tube heat exchanger. Sensible heat transfer is considered in the analysis and the heat exchanger is developed for actual operating conditions in a chemical plant. The heat exchanger is a concentric tube heat exchanger where hot oil exchanges heat with hot water. Hot oil is in the inner pipe and the heating medium, hot water, is in the outer pipe (annular side) of the heat exchanger. An analytical model employing effectiveness-number of transfer units (ε-NTU) approach and log mean temperature difference (LMTD) approach were employed in the design of the concentric tube heat exchanger. In the design process, performance charts were developed for concentric tube heat exchanger. Performance charts describe the performance of the heat exchanger in terms of crucial dimensionless parameters. Performance charts help to select the right number of transfer units (NTU) for the given heat exchanger. Both parallel and counter flow configurations were considered for the design analysis. Likewise, a numerical model was also considered in the design of the heat exchanger. The results from the analysis are presented and compared. From the results it can be seen that both numerical and analytical approaches produce the exact same results. The designer certainly has the flexibility to choose an appropriate design methodology based on the available inputs and requirements.

15 October 2012 in Heat Transfer Engineering
Verified
Journal Article
Closed access
KSKarthik Silaipillayarputhur
Karthik Silaipillayarputhur
SIStephen Idem
Stephen Idem
A steady-state performance model of multirow multipass cross-flow tubular heat exchangers is developed. The proposed matrix approach uses the concepts of local effectiveness, energy balance, and number of transfer units (NTU) applied to every pass/row in the cross-flow heat exchanger to predict thermal performance. The method can predict the total effectiveness of assemblies of heat exchangers. Several circuiting configurations, such as overall counter-cross-flow, overall parallel cross-flow, and fluids in parallel in one of the streams, were considered. Predictions of the steady heat transfer performance of selected multirow multipass cross-flow heat exchangers are obtained by applying the general matrix approach. The heat exchanger geometries selected for the comparative study represent common cross-flow heat exchanger configurations used in industry. For these heat exchangers the overall heat exchanger effectiveness values were computed for various capacity rate ratios and NTU values. The validity of the matrix approach was then verified by comparing the resulting predictions with those obtained using the P-NTU approach and the Domingos method for the selected complex cross-flow heat exchanger configurations.

14 June 2018 in International Journal of Engineering & Technology
Verified
Journal Article
Closed access
HKHassan Khurshid
Hassan Khurshid
KSKarthik Silaipillayarputhur
Karthik Silaipillayarputhur
Saudi Arabia is one of the warmer countries in the Middle East region. In the summer months, the ambient temperature reaches 50°C on regular basis. This high temperature has a direct effect on the elevation of water temperatures inside the domestic and commercial over-head tanks. The tanks are predominantly installed on the roof of the buildings without any shade or insulation and are exposed to the direct irradiation from the sun. The tank material is not capable of reducing the effect of solar radiation. Therefore, water gets very hot in the afternoon that it is impossible for the occupants of the residential buildings to take a shower or even wash their hands. This paper studied the effect of solar irradiation on the water temperature in the over-head storage water tanks during the summer months. The temperature rise in the water storage tank was considered for different cases, (i.e.) a free standing tank exposed to direct sun’s irradiation, a tank with shade, a tank with fiber glass insulation, and a tank having insulation along with shade. An analytical model was developed to study the effects of sun’s irradiation and the results were compared with that of experimentation. The results from the water storage tank having insulation exhibited encouraging results.

4 March 2018 in International Journal of Engineering & Technology
Verified
Journal Article
Open access
PDF file
KSKarthik Silaipillayarputhur
Karthik Silaipillayarputhur
The most common feature among the best known companies in the world is safety. In fact, process safety and manufacturing productivity go hand in hand. In the last century, a number of catastrophic accidents have drawn the attention of regulators towards process safety. In several developed, industrialized countries, strict regulations and standards are applied to emphasize process safety. In fact, in such countries, these are the required minimum for maintaining business license and permits. However, in developing and in under developed nations, the issue of process safety and their importance is still being debated. Process safety cannot just be driven by a set of rules, regulations, policies, etc. Multitudes of items are required in establishing and maintaining a safe and a reliable work environment. Such items, though can be expressed readily in paper, are quite arduous to establish in a highly competitive environment. The legislation, the government regulations, banking policies, management commitment, cumulatively share the responsibility in establishing organizations judiciously managing process safety. This paper reviews certain critical aspects in establishing a successful process safety management (PSM) program. Furthermore, the paper reviews the various elements that contribute towards the creation of a worthwhile PSM program.

9 March 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
AEABDULAZIZ ELSINAWI
ABDULAZIZ ELSINAWI
KSKarthik Silaipillayarputhur
Karthik Silaipillayarputhur
TATawfiq AbdulAziz Al-Mughanam
Tawfiq AbdulAziz Al-Mughanam
CHChristopher Hardacre
Christopher Hardacre
In this work, the performance of selected ionic liquid-water mixtures was investigated for an acetone cooling application in a process plant using a double pipe heat exchanger. Cooling media such as river water and ionic liquid-water mixtures were compared, specifically water-saturated quaternary phosphonium-based carboxylate ionic liquids were considered in this work. Ionic liquids generally have high thermal stability, resist degradation, and provide higher temperatures at low vapor pressures and for these reasons, ionic liquids can be a good substitute for conventional heat transfer fluids. At each condition, the performance of the ionic liquid mixture was compared with that of water. For the designated cooling application, the performance of water was much better than the ionic liquid mixtures.

2 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
KSKarthik Silaipillayarputhur
Karthik Silaipillayarputhur
TATawfiq AbdulAziz Al-Mughanam
Tawfiq AbdulAziz Al-Mughanam
All process industries involve the usage of heat exchanger equipment and understanding its performance during the design phase is very essential. The present research work specifies the performance of a pure cross flow heat exchanger in terms of dimensionless factors such as number of transfer units, capacity rate ratio, and heat exchanger effectiveness. Steady state sensible heat transfer was considered in the analysis. The matrix approach that was established in the earlier work was used in the study. The results were depicted in the form of charts, tables, and performance equations. It was observed that indeterminately increasing the number of transfer units past a threshold limit provided very marginal improvement in the performance of a pure cross flow heat exchanger. Likewise, flow pattern in a heat exchanger is usually assumed either as mixed or unmixed. However, due to various operating conditions, partially mixed conditions do exist. This work considers partially mixed conditions in the tube side of the heat exchanger. The correction factor for heat exchanger effectiveness was developed to accommodate partially mixed flow conditions in the pure cross flow heat exchanger.