Kazuo Yamamoto

Prof. Kazuo Yamamoto

Chubu University
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
TMTakuto Matsui
Takuto Matsui
KYKazuo Yamamoto
Kazuo Yamamoto
SSShinichi Sumi
Shinichi Sumi
NTNawakun Triruttanapiruk
Nawakun Triruttanapiruk
In recent years, there have been several reports of blade damage caused by lightning strikes on wind turbines. A few of these accidents have resulted in more serious secondary damage owing to the continued rotation of the damaged blades. To prevent the initial damage from spreading in this manner, wind farms in the regions of Japan vulnerable to winter lightning were required to introduce lightning detection systems, which can accurately detect when lightning strikes the wind turbine and then immediately stop the rotation of the blades. Normally, when the system detects a lightning strike to a wind turbine and stops operation, the process of restarting is initiated only after the soundness of the blades is confirmed by visual inspection. However, in bad weather, it is often difficult to check the soundness of the blade visually, and the resulting delay in the restart process prolongs the downtime and reduces the availability of the wind turbine. In this paper, we report the results of using the supervisory control and data acquisition (SCADA) system data to check the soundness of the blades after a lightning strike to resume operations more quickly, thereby increasing up-time.

6 April 2022 in Electric Power Systems Research
Verified
Journal Article
Closed access
TMTakuto Matsui
Takuto Matsui
KYKazuo Yamamoto
Kazuo Yamamoto
JOJun Ogata
Jun Ogata

1 July 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
HXHaoyan Xue
Haoyan Xue
AAAkihiro Ametani
Akihiro Ametani
KYKazuo Yamamoto
Kazuo Yamamoto
A generalized formulation of electromagnetic fields generated from a multi-phase underground cable is proposed based on a complete solution of Maxwell equations. The lateral electromagnetic field components, the shielding effect of cables and the phase currents at high frequencies of a three phase underground cable are evaluated by the newly derived formulas. The accuracies of the recently developed extended transmission line approach of underground cables are investigated based on the performance of electromagnetic field components. It is also shown that Numerical Electromagnetics Code verifies the results calculated from the new formulas presented in this paper.

22 December 2009 in IEEJ Transactions on Electrical and Electronic Engineering
Verified
Journal Article
Closed access
PDF file
KYKazuo Yamamoto
Kazuo Yamamoto
SYShunichi Yanagawa
Shunichi Yanagawa
SSShozo Sekioka
Shozo Sekioka
SYShigeru Yokoyama
Shigeru Yokoyama

11 November 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
HXHaoyan Xue
Haoyan Xue
AAAkihiro Ametani
Akihiro Ametani
KYKazuo Yamamoto
Kazuo Yamamoto
The characteristics of external electromagnetic fields (EEMFs) produced by underground cables in the lossy earth are further investigated and studied. This paper develops an excitation current in the cables with the bi-directional propagation for the calculations of the vectors of EEMFs. By adopting the newly proposed method in this paper, it allows the considerations of the terminating conditions and the lengths of the cable on the calculations of the vectors of EEMFs. Moreover, the vectors of EEMFs are calculated, compared and discussed using various load/source impedances. The effects of lengths of underground cables on the vectors of EEMFs are studied. Also, the frequency-dependent earth models are included into the investigations of the EEMFs. The results presented in this paper are compared and verified with the Numerical Electromagnetics Code.

19 January 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MKMorioki Kose
Morioki Kose
STSaki Tanaka
Saki Tanaka
KYKazuo Yamamoto
Kazuo Yamamoto
SSShozo Sekioka
Shozo Sekioka
YBYoshihiro Baba
Yoshihiro Baba
NNNaoto Nagaoka
Naoto Nagaoka
Many failures of wind turbine blades and electrical equipment due to powerful lightning strikes have occurred. The lightning-induced wind turbine failures that have occurred in recent years can be classified into two main categories. The first is a mechanical component failure. The second is a failure or malfunction of electric or electronic equipment inside or around the wind turbine due to an increase in the potential of the wind turbine grounding system or the electromagnetic induction caused by the lightning strike. In the latter case, the equipment often fails owing to the increase in the potential of the grounding system, the method of suppressing the potential rise by laying a grounding wire vertically or horizontally to the wind turbine foundation is adopted. We propose an empirical expression for the effective length of counterpoises connected to a large grounding electrode such as a wind turbine foundation, and verify the expression using finite-difference time-domain (FDTD) method.