Kevin Joseph Haworth

Dr. Kevin Joseph Haworth

University of Cincinnati, Cincinnati, Ohio, USA
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2009 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MFM.L. Fabiilli
M.L. Fabiilli
Kevin Joseph HaworthKevin Joseph Haworth
Kevin Joseph Haworth
NFN.H. Fakhri
N.H. Fakhri
OKOliver Kripfgans
Oliver Kripfgans
PCPaul L. Carson
Paul L. Carson
JFJ.B. Fowlkes
J.B. Fowlkes
The vaporization of a superheated droplet emulsion into gas bubbles using ultrasound-termed acoustic droplet vaporization (ADV)-has potential therapeutic applications in embolotherapy and drug delivery. The optimization of ADV for therapeutic applications can be enhanced by understanding the physical mechanisms underlying ADV, which are currently not clearly elucidated. Acoustic cavitation is one possible mechanism. This paper investigates the relationship between ADV and inertial cavitation (IC) thresholds (measured as peak rarefactional pressures) by studying parameters that are known to influence the IC threshold. These parameters include bulk fluid properties such as gas saturation, temperature, viscosity, and surface tension; droplet parameters such as degree of superheat, surfactant type, and size; and acoustic properties such as pulse repetition frequency and pulse width. In all cases the ADV threshold occurred at a lower rarefactional pressure than the IC threshold, indicating that the phase transition occurs before IC events. The viscosity and temperature of the bulk fluid are shown to influence both thresholds directly and inversely, respectively. An inverse trend is observed between threshold and diameter for droplets in the 1 to 2.5 mum range. Based on a choice of experimental parameters, it is possible to achieve ADV with or without IC.

25 October 2016 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
Kevin Joseph HaworthKevin Joseph Haworth
Kevin Joseph Haworth
KBKenneth B. Bader
Kenneth B. Bader
KRKyle T. Rich
Kyle T. Rich
CHChristy K. Holland
Christy K. Holland
TMT. Douglas Mast
T. Douglas Mast
Passive cavitation detection has been an instrumental technique for measuring cavitation dynamics, elucidating concomitant bioeffects, and guiding ultrasound therapies. Recently, techniques have been developed to create images of cavitation activity to provide investigators with a more complete set of information. These techniques use arrays to record and subsequently beamform received cavitation emissions, rather than processing emissions received on a single-element transducer. In this paper, the methods for performing frequency-domain delay, sum, and integrate passive imaging are outlined. The method can be applied to any passively acquired acoustic scattering or emissions, including cavitation emissions. To compare data across different systems, techniques for normalizing Fourier transformed data and converting the data to the acoustic energy received by the array are described. A discussion of hardware requirements and alternative imaging approaches is additionally outlined. Examples are provided in MATLAB.

1 August 2010 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
MFMario L. Fabiilli
Mario L. Fabiilli
Kevin Joseph HaworthKevin Joseph Haworth
Kevin Joseph Haworth
ISIan E. Sebastian
Ian E. Sebastian
OKOliver Kripfgans
Oliver Kripfgans
PCPaul L. Carson
Paul L. Carson
JFJ. Brian Fowlkes
J. Brian Fowlkes

1 July 2012 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
Kevin Joseph HaworthKevin Joseph Haworth
Kevin Joseph Haworth
TMT. Douglas Mast
T. Douglas Mast
KRKirthi Radhakrishnan
Kirthi Radhakrishnan
MBMark T. Burgess
Mark T. Burgess
JKJonathan Kopechek
Jonathan Kopechek
CHChristy K. Holland
Christy K. Holland
Previously, passive cavitation imaging has been described in the context of continuous-wave high-intensity focused ultrasound thermal ablation. However, the technique has potential use as a feedback mechanism for pulsed-wave therapies, such as ultrasound-mediated drug delivery. In this paper, results of experiments and simulations are reported to demonstrate the feasibility of passive cavitation imaging using pulsed ultrasound insonations and how the images depend on pulsed ultrasound parameters. The passive cavitation images were formed from channel data that was beamformed in the frequency domain. Experiments were performed in an invitro flow phantom with an experimental echo contrast agent, echogenic liposomes, as cavitation nuclei. It was found that the pulse duration and envelope have minimal impact on the image resolution achieved. The passive cavitation image amplitude scales linearly with the cavitation emission energy. Cavitation images for both stable and inertial cavitation can be obtained from the same received data set.

1 October 2010 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
MZM. Zhang
M. Zhang
MFM.L. Fabiilli
M.L. Fabiilli
Kevin Joseph HaworthKevin Joseph Haworth
Kevin Joseph Haworth
JFJ.B. Fowlkes
J.B. Fowlkes
OKOliver Kripfgans
Oliver Kripfgans
PCPaul L. Carson
Paul L. Carson

1 September 2011 in Academic Radiology
Verified
Journal Article
Closed access
MZMan Zhang
Man Zhang
MFMario L. Fabiilli
Mario L. Fabiilli
Kevin Joseph HaworthKevin Joseph Haworth
Kevin Joseph Haworth
FPFrederic Padilla
Frederic Padilla
SSScott D. Swanson
Scott D. Swanson
JFJeffrey Brian Fowlkes
Jeffrey Brian Fowlkes