KIRAN RANA

Ms. KIRAN RANA


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
KRKIRAN RANA
KIRAN RANA
MBMonalisa Biswal
Monalisa Biswal
NKNand Kishor
Nand Kishor
RNRicha Negi
Richa Negi
In high voltage direct current (HVDC) systems, the occurrence of short circuits results in a rapid rise in line current, adversely affecting the interconnected alternating current (AC) grid. Particularly in voltage source‐based multimodular converter (MMC) HVDC networks, such transients pose a significant threat to power converter units. Traditional relaying algorithms prove inadequate for safeguarding AC‐DC‐linked HVDC networks. Both the direct current (DC) and alternating current (AC) segments of such networks demand robust protection mechanisms. Signal processing‐based techniques offer valuable insights during fault events, yet challenges such as noise interference, mode missing, and harmonics generation during faults persist, leading to erroneous conclusions. To address this, we introduce Synchro Squeezed Transform (SST) in this study to mitigate ambiguity in relaying algorithm decisions. SST facilitates the extraction of amplitude and effective instantaneous frequency of AC signals. The proposed method employs the Rényi entropy of time‐frequency representation (TFR) as the primary logic, followed by the estimation of the spectrum‐based Teager–Kaiser Energy Operator (TKEO) for DC signals as the secondary logic. These combined logics enable the identification of various AC and DC faults in Voltage Source Converter (VSC)‐based bipolar HVDC networks. Simulation results, including comparisons with existing approaches, demonstrate the efficacy of the proposed methodology in enhancing fault detection and classification accuracy in AC‐DC‐linked HVDC networks.

12 March 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KRKIRAN RANA
KIRAN RANA
NKNand Kishor
Nand Kishor
RNRicha Negi
Richa Negi
MBMonalisa Biswal
Monalisa Biswal
High-voltage direct current (HVDC) transmission is preferred over high-voltage alternating current (HVAC) for long power lines for asynchronous power grid interconnection and high-level renewable energy integration. The control and protection functions associated with HVDC systems help with fast and secure clearance of faults. The control and protection challenges in the embedded HVDC network are of great concern for the stable and secure operation of an HVDC network. The DC fault current may reach an extremely high level in a rather short period because of the low impedance in a DC system, which is dangerous for converters, and disturbances in the AC network directly influence the performance of the HVDC system. Sometimes, faults on the AC side may lead to disconnection or failure of the DC link, causing reliability problems as well as huge economic losses. AC and DC protection solutions are being developed for HVDC systems to enhance their sustainability and reliability. As such, AC and DC faults should be detected and cleared at a faster rate. Therefore, in this article, the feasibility of the synchro-squeezed transform (SST) is analyzed for detection purposes. For more accurate and faster detection, the signal is first decomposed using the empirical mode decomposition (EMD) technique, and then the SST is applied. A discrete Teager energy (DTE) spectrum is obtained with the processed signal, which works as the detection index. The algorithm shows low sampling frequency requirements, with higher efficiency and reliability for the purpose. PSCAD/EMTDC version 4.6 software and MATLAB 2022a software is used for the modeling and simulation.