Kirill Kabalyk

Dr. Kirill Kabalyk

Institute of Turbomachinery, Lodz University of Technology, Lodz, Poland
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
ABArkadiusz Bednarz
Arkadiusz Bednarz
Kirill KabalykKirill Kabalyk
Kirill Kabalyk
RJRobert Jakubowski
Robert Jakubowski
RBRafał Bartłomowicz
Rafał Bartłomowicz
The aim of this publication was to investigate the effects the blade count of a high-pressure centrifugal compressor’s impeller has on the performance of the DGEN 380 turbine engine at take-off. The study began with the development of a zero-dimensional thermo-fluid model of the engine. The model was matched with experimental data from the WESTT CS/BV virtual test bench for the baseline count and then implemented to analyse the engine behaviour at alternative counts. The corresponding changes in the compressor pressure ratio and efficiency were modelled in a commercial 3D CFD software and transferred to the zero-dimensional model with proper scaling. The results proved that the baseline design lied in the optimal range of thrust-specific fuel consumption. The increase in the blade count led to a crisis of the aerodynamic loading at the splitters, so that no further rise in the pressure ratio could be achieved. The results of the study could be implemented by mechanical engineers while solving the tasks of the maintenance and modernisation of gas turbines with radial compressors.

1 January 2017
Verified
Conference Paper
Closed access
PDF file
WKWladyslaw Kryllowicz
Wladyslaw Kryllowicz
PSPiotr Swider
Piotr Swider
ZKZbigniew Kozanecki
Zbigniew Kozanecki
Kirill KabalykKirill Kabalyk
Kirill Kabalyk
ZJZbigniew Kozanecki Jr
Zbigniew Kozanecki Jr
The article is devoted to the description of the modernization of a multihull process centrifugal compressor for synthesis gas. The main reason for the revamp was the desire to adapt the conventional machine (45 years of operation) for newer operational requirements: the decrease of compressor discharge pressure to the level of 140 bar from the level of 211 bar with the corresponding alteration of the mass flow rate. The scheme accepted as a final modernization conception required the manufacturing of three completely new rotor and casing assemblies. Major design modifications concerned the impellers’ geometry, introduction of vaneless diffusers and the abradable labyrinth seals. Most of the stages were “optimized” using the in-house semi-empirical 1D code and ANSYS CFX commercial code. The performance of a single optimized stage was tested experimentally. The paper reveals the main results of these measurements and their comparison to numerical simulations results. The start-up tests of the modernized assembly showed its almost 100% conformity to the requirements in the output and the efficiency rise of about 5%.

11 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
Grzegorz LiśkiewiczGrzegorz Liśkiewicz
Grzegorz Liśkiewicz
Kirill KabalykKirill Kabalyk
Kirill Kabalyk
AJAndrzej Jaeschke
Andrzej Jaeschke
FGFilip Grapow
Filip Grapow
Michał KulakMichał Kulak
Michał Kulak
WKWładysław Kryłłowicz
Władysław Kryłłowicz
Unstable flow structures cause inevitable energy losses in all power energy systems, including turbomachines. In this study, a set of analyses was conducted with the use of spectral maps on the pressure signals obtained from an industrial centrifugal compressor. The spectral maps provide one a detailed visualization of the flow conditions present in the machine along the performance curve and to distinguish the flow phenomena present prior to the surge. The method accuracy is especially useful in detecting the inlet recirculation. The study was conducted at four impeller rotational speeds with varying loads imposed by a valve at the outlet. At each speed, the machine experienced different stages of unstable flow conditions prior to the surge. Five main frequency peaks that appeared in all cases were identified and discussed. The surge was observed at all impeller speeds. At lower ones, however, it appeared at higher valve closures. At higher speeds, the surge was much more intense. The study has also shown that the inlet recirculation appears also for the closed-type industrial impeller. The phenomenon was present in all conditions. The higher impeller speed, the faster onset of the inlet recirculation was. This structure has a strong potential for an early instability warning because it appears in various types of impellers, has a very particular spectral structure and its positioning is very predictable. This study gives another example of the inlet recirculation universality and potential for efficient anti-surge protection.

16 June 2014
Verified
Conference Paper
Closed access
PDF file
Kirill KabalykKirill Kabalyk
Kirill Kabalyk
Grzegorz LiśkiewiczGrzegorz Liśkiewicz
Grzegorz Liśkiewicz
LHLongin Horodko
Longin Horodko
WKWładysław Kryłłowicz
Władysław Kryłłowicz
MSMatthew Stickland
Matthew Stickland
The influence of plenum volume on surge phenomenon in a centrifugal blower was studied by means of quasi-dynamic analysis. In this procedure, signals were gathered at 5 pressure tappings at 146 different positions of the throttling valve controlling the mass flow rate. Frequency spectra obtained by means of Fourier analysis are combined together in the form of colour maps with frequency as the abscissa and valve position as the ordinate. Such a map provides high-resolution information about spectral structures of pressure signals attained at different mass flow rates. Analysis was conducted at two system configurations characterized by different volumes between the blower and the valve i.e. plenum volume. Research confirmed that in both cases the first disturbances appear in the vicinity of the impeller leading edge in the same position of a throttling valve before the surge. Arising flow structure is characterized by strong and random pressure jumps and does not have any dominating frequency. At further valve closure pressure disturbances propagate towards the volute and at deep surge the strongest peaks are observed at the outlet. The moment of deep surge onset is also independent of the plenum volume, however, a difference is observed in the frequency and amplitude of the main modes. With the higher outlet volume the observed oscillations fit well to the frequency of a Helmholtz resonator while, in the case of the smaller volume, the frequency is higher than the frequency of a corresponding Helmholtz resonator.

16 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
Kirill KabalykKirill Kabalyk
Kirill Kabalyk
AJAndrzej Jaeschke
Andrzej Jaeschke
Grzegorz LiśkiewiczGrzegorz Liśkiewicz
Grzegorz Liśkiewicz
Michał KulakMichał Kulak
Michał Kulak
TSTomasz Szydłowski
Tomasz Szydłowski
RPRobert Pietruszewski
Robert Pietruszewski
The article describes an assessment of possible changes in constant fatigue life of a medium flow-coefficient centrifugal compressor impeller subject to operation at close-to-surge point. Some aspects of duct acoustics are additionally analyzed. The experimental measurements at partial load are presented and are primarily used for validation of unidirectionally coupled fluid-structural numerical model. The model is based on unsteady finite-volume fluid-flow simulations and on finite-element transient structural analysis. The validation is followed by the model implementation to replicate the industry-scale loads with reasonably higher rotational speed and suction pressure. The approach demonstrates satisfactory accuracy in prediction of stage performance and unsteady flow field in vaneless diffuser. The latter is deduced from signal analysis relying on continuous wavelet transformations. On the other hand, it is found that the aerodynamic incidence losses at close-to-surge point are underpredicted. The structural simulation generates considerable amounts of numerical noise, which has to be separated prior to evaluation of fluid-induced dynamic strain. The main source of disturbance is defined as a stationary region of static pressure drop caused by flow contraction at volute tongue and leading to first engine-order excitation in rotating frame of reference. Eventually, it is concluded that the amplitude of excitation is too low to lead to any additional fatigue.

11 January 2016 in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Verified
Journal Article
Closed access
Kirill KabalykKirill Kabalyk
Kirill Kabalyk
WKWładysław Kryłłowicz
Władysław Kryłłowicz
Grzegorz LiśkiewiczGrzegorz Liśkiewicz
Grzegorz Liśkiewicz
LHLongin Horodko
Longin Horodko
RMRadomir Magiera
Radomir Magiera
The article is devoted to the experimental investigation of the interactions between the amplitudes and frequencies of surge in a single-stage centrifugal blower and the configuration of its inlet duct. In this work, the term ‘configuration’ implies the combination of the following: the volume of the duct, the presence of the filter inside the duct and the inlet guide vane position. The high-response pressure measurements were performed at three points along the impeller shroud (inlet, middle, outlet) and at a single point downstream the volute outlet and then processed with the use of fast Fourier transform (FFT). The results of the measurements show that the response of the surging system to a change introduced into the duct’s configuration is complex. The closure of the inlet guide vane typically causes a drop in the amplitude and frequency of fluctuating pressure. The introduction of a filter body into the duct most often damps the amplitudes of fluctuations, but leaves the frequencies unaltered. The change of the duct’s volume controls the rate of this damping.