Kui-cheng Wang

Mr. Kui-cheng Wang

Harbin Engineering University
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Yan-lin WangYan-lin Wang
Yan-lin Wang
KWkeyi wang
keyi wang
Kui-cheng WangKui-cheng Wang
Kui-cheng Wang
ZMZong Jun Mo
Zong Jun Mo
Safety is a significant evaluation index of rehabilitation medical devices and a significant precondition for practical application. However, the safety evaluation of cable-driven rehabilitation robots has not been reported, so this work aims to study the safety evaluation methods and evaluation index of cable-driven rehabilitation robots. A bionic muscle cable (BM cable) is proposed to construct a bionic muscle cable-driven lower limb rehabilitation robot (BM-CDLR). The working principle of the BM-CDLR is introduced. The safety performance factors are defined based on the mechanical analysis of the BM-CDLR. The structural safety evaluation index and the use safety evaluation index of the BM-CDLR are given by comprehensively considering the safety performance factors and a proposed speed influence function. The effect of the structural parameters of the elastic elements in the BM cable on the safety performance factors and safety of the BM-CDLR is analyzed and verified by numerical simulations and experimental studies. The results provide the basis for further study of the compliance control strategy and experiments of the human-machine interaction of the BM-CDLR.

26 May 2021 in IEEE Access
Verified
Journal Article
Open access
Yan-lin WangYan-lin Wang
Yan-lin Wang
KWkeyi wang
keyi wang
XLXiang Li
Xiang Li
ZMZong-Jun Mo
Zong-Jun Mo
Kui-cheng WangKui-cheng Wang
Kui-cheng Wang
The passive training with fixed trajectory is more suitable for the initial rehabilitation training of patients with no muscle strength in the affected limb. In order to meet the needs of patients' rehabilitation training in different rehabilitation stages and improve the active participation and rehabilitation training effect of patients, a fuzzy sliding mode variable admittance (FSMVA) controller based on safety evaluation and supervision is proposed for the cable-driven lower limb rehabilitation robot (CDLR) in this paper. The FSMVA controller consists of an inner loop fuzzy sliding mode controller, an outer loop variable admittance controller, and a safety evaluation and supervision module. Through the safety evaluation index of the CDLR system and the comprehensive evaluation of patients' rehabilitation effect given by rehabilitation physiotherapists, a real-time adjustment algorithm of variable admittance controller parameters is designed, which can realize the real-time switching of training modes and adjustment of variable admittance controller parameters in active training mode and passive training mode. The trajectory tracking experiments with no admittance, fixed admittance, and variable admittance based on safety evaluation and supervision were carried out on the experimental platform. The experimental results show that the proposed FSMVA control strategy has high position control accuracy in the active training mode. In addition, the training intensity and the active participation of patients can be increased according to the patient's exercise ability. In the passive training mode, according to the training needs of patients, the amount of the trajectory adjustment can be increased to improve the comfort of the training process and the safety of patients. It lays a foundation for the further study of the evaluation system of the rehabilitation training process and the experiment of human-machine interaction compliance.