Background: The purpose of this study was to assess the inter-examiner repeatability of subjective refraction across diverse age cohorts, an aspect not previously investigated. Methods: A cross-sectional, randomized study enrolled 86 participants (mean age: 37.0 ± 18.0 years), distributed into three groups: youth, non-presbyopic adults, and presbyopic adults. Each participant underwent three subjective refractions by three different optometrists on separate days. Repeatability analysis encompassed all refractive variables (M, J0, and J45). Results: There were no significant differences between optometrists in all refractive variables for either the overall sample or across age groups (p ≥ 0.05). Additionally, no correlation was found between participants’ age and the mean difference in refractive variables across optometrists (p ≥ 0.05). The 95% confidence interval of repeatability (r) for the total sample was ±0.70 D for M, ±0.29 for J0, and ±0.21 D for J45. Conclusions: Based on these findings and previous research, it is suggested to establish 95% limits of agreement of ±0.75 D for M, and between ±0.25 D and ±0.50 D for both J0 and J45 when validating new refraction systems compared to subjective refraction as the gold standard, regardless of the age of the subjects evaluated.
Purpose. To evaluate the agreement and repeatability between a new commercially available binocular open-field wavefront autorefractor, as part of the Eye Refract system, and a monocular closed-field wavefront autorefractor (VX110). Methods. A cross-sectional, randomized, and single-masked study was performed. Ninety-nine eyes of 99 healthy participants (37.22 ± 18.04 years, range 8 to 69 years) were randomly analyzed. Three measurements with the Eye Refract and the VX110 were taken on three different days, under noncycloplegic conditions. Mean spherical equivalent (MSE), cylindrical vectors (J0 and J45), and binocular corrected distance visual acuity (BCDVA) were compared between both autorefractors. An intersession repeatability analysis was done considering the values of repeatability (Sr) and its 95% limit (r). Results. The VX110 showed more negative values () in terms of MSE in comparison with the Eye Refract (0.20 D). Regarding cylindrical vectors, J45 showed statistically significant differences () between both wavefront autorefractors, but they were not clinically relevant (<0.05 D). In BCDVA, there were no statistically significant differences () between both wavefront autorefractors. Additionally, the Eye Refract was more repeatable than the VX110 in terms of both MSE (SrEYE REFRACT = 0.21 D, SrVX110 = 0.53 D) and J0 (SrEYE REFRACT = 0.12 D, SrVX110 = 0.35 D). Conclusions. The Eye Refract provided enough accuracy and reliability to estimate refractive errors in different age groups, achieving better results than the VX110. Therefore, the Eye Refract proved to be a useful autorefractor to be incorporated into clinical practice.
To assess accommodation and spherical aberration changes during one year of orthokeratology lens wear and one month after lens cessation. A prospective, randomized, longitudinal study was conducted on forty-seven young healthy subjects at the Optometry Clinic of the Complutense University of Madrid (Spain). Non-cycloplegic refraction, high and low uncorrected visual acuity, high and low best corrected visual acuity, accommodative lag, horizontal near phoria, corneal topography, and high-order aberrations were performed at baseline, 1-day, 1-week, 1-, 6- and 12-months of lens wear and after one month of wash out period. p < 0.05 was considered as statistically significant. Spherical equivalent refraction (SE) was -3.23 ± 1.57D at baseline and -0.36 ± 0.64D after 12-months of lens wear, while accommodative lag changed from 0.53 ± 0.39D to 0.15 ± 0.29D after one year of lens wear. No significant differences were found when comparing SE at baseline and after one month of lens cessation (p > 0.05). A high correlation was found between the accommodative lag at baseline and after 12 M of lens wear. 22 out of 25 subjects with exophoria at baseline showed a significant reduction in the deviation at 12-months (p < 0.05). Total spherical aberration increased during all visits due to the lens wear (p < 0.05) although internal spherical aberration showed a significant decrease for 1-week, 1-month and 12-month visits (p < 0,05). Orthokeratology lenses may change the accommodative response of the patient as a reduction on accommodative lag on exophoric patients and an overall increase on the internal spherical aberrations was found during treatment but return to nearly baseline values when cessation.
Objective: We assess the prevalence of myopia and its associated factors among schoolchildren in Madrid, Spain, where school-based data using cycloplegic refraction are currently scarce. Methods: A cross-sectional study was conducted in 39 randomly selected schools in Madrid, targeting children in the second (6–7 years) and sixth grades (11–12 years). Parents completed questionnaires detailing family ocular history, the child’s lifestyle, and screen time. Socio-economic status was inferred from the Human Development Index of school districts. Children were examined using a two-stage approach: initial screening with visual acuity testing and Plusoptix photorefraction (myopia screening cut-off ≤ 0.00 D spherical equivalent), followed by confirmatory cycloplegic autorefraction (three drops of cyclopentolate 1% administered at 10 min intervals), with myopia defined as spherical equivalent ≤ −0.50 D. Statistical analyses included chi-square tests and logistic regression models to evaluate associated factors. Results: Of 3680 children invited, 2489 (67.6%) were examined. Myopia prevalence was 6.5% in second grade and 18.7% in sixth grade. Family history of myopia was a significant risk factor (OR 2.04; 95% CI: 1.53–2.70; p < 0.001 for both parents). Outdoor activity during weekends was associated with lower myopia prevalence (OR 0.50; 95% CI: 0.37–0.66; p < 0.01 for 2–6 h). Screen time was not a significant factor in multivariate analysis. Conclusions: This large school-based study using cycloplegic refraction provides more accurate prevalence data for Spanish schoolchildren. It confirms family history as a major risk factor and highlights the association of outdoor activities with lower prevalence of myopia. These results underline the need for preventive measures and suggest areas for future interventional research.
Background/Objectives: The objective of this study was to examine the trend of treatment zone (TZ) decentration over 12 months of orthokeratology (OK) wear using two Corneal Refractive Therapy (CRT) lens designs: standard (STD) and dual axis (DA). Methods: A prospective, randomized, longitudinal study was conducted at the Optometry Clinic of the Complutense University of Madrid. Subjects were randomly fitted with an STD design or DA design in one of the eyes. Refraction, uncorrected visual acuity (VA), and corneal topography were performed at baseline and after 1 night, 1 week, and 1, 3, 6, and 12 months of lens wear. Subjects requiring lens parameter adjustments or replacements after 3 months were excluded. Decentration was measured by subtracting pre-OK from post-OK tangential curvature maps at each visit, with decentration distance and corneal optical TZ being measured using MATLAB. Correlations between decentration and visual acuity (VA) were also analyzed. Results: A total of 30 healthy children (17 females and 13 males) with a mean age of 12.83 ± 2.42 years (range: 8–17 years) completed all the visits. No statistically significant differences (p > 0.05) were found between lens designs in horizontal, vertical, nor total decentration through the visits. However, for the STD design, horizontal and total decentration increased significantly at the last visit (p < 0.05). For the DA design, no significant differences were found over time (p > 0.05). No correlation was found between decentration and VA. Conclusions: Total decentration in both lens designs was similar throughout one year of follow-up. The standard design tended to decenter horizontally during the last 6 months, while the dual-axis design maintained consistent decentration throughout the year.
Background: Since accommodation may be a source of error affecting the inter-optometrist repeatability of subjective refraction, this study investigated whether the use of cycloplegia could improve this repeatability. Methods: A randomized cross-sectional study was conducted on 42 young hyperopes (18.2 ± 7.7 years, range 6 to 31 years). Subjective refraction was performed by two different optometrists in two measurement sessions: one day without cycloplegia and, on a different day, with cycloplegia, in random order. The inter-optometrist repeatability of all refractive variables (M, J0, and J45) was analyzed, selecting one eye randomly, in terms of the 95% confidence interval of repeatability (r). Results: No statistically significant differences were found between the optometrists for any refractive variable, both with and without cycloplegia (p ≥ 0.05). Furthermore, no correlation was found between participants’ age and the refractive differences between optometrists under both cycloplegic conditions (p ≥ 0.05). However, the use of cycloplegia improved the inter-optometrist repeatability of M (r = 0.37 D) compared to the non-cycloplegic measurements (r = 0.62 D). Conclusions: These results suggest that accommodation in young hyperopes is likely a primary source of error that could explain the discrepancies in subjective refraction between optometrists.