Laura De Rosa

Dr. Laura De Rosa

Institute of Clinical Physiology, National Research Council, Pisa, Italy
+1
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2023 in Life
Verified
Journal Article
Open access
PDF file
Laura De RosaLaura De Rosa
Laura De Rosa
SLSerena L'Abbate
Serena L'Abbate
Claudia KusmicClaudia Kusmic
Claudia Kusmic
Francesco FaitaFrancesco Faita
Francesco Faita
Background and Aim: Ultrasound (US) imaging is increasingly preferred over other more invasive modalities in preclinical studies using animal models. However, this technique has some limitations, mainly related to operator dependence. To overcome some of the current drawbacks, sophisticated data processing models are proposed, in particular artificial intelligence models based on deep learning (DL) networks. This systematic review aims to overview the application of DL algorithms in assisting US analysis of images acquired in in vivo preclinical studies on animal models. Methods: A literature search was conducted using the Scopus and PubMed databases. Studies published from January 2012 to November 2022 that developed DL models on US images acquired in preclinical/animal experimental scenarios were eligible for inclusion. This review was conducted according to PRISMA guidelines. Results: Fifty-six studies were enrolled and classified into five groups based on the anatomical district in which the DL models were used. Sixteen studies focused on the cardiovascular system and fourteen on the abdominal organs. Five studies applied DL networks to images of the musculoskeletal system and eight investigations involved the brain. Thirteen papers, grouped under a miscellaneous category, proposed heterogeneous applications adopting DL systems. Our analysis also highlighted that murine models were the most common animals used in in vivo studies applying DL to US imaging. Conclusion: DL techniques show great potential in terms of US images acquired in preclinical studies using animal models. However, in this scenario, these techniques are still in their early stages, and there is room for improvement, such as sample sizes, data preprocessing, and model interpretability.

27 August 2024 in Liver International
Verified
Journal Article
Open access
Laura De RosaLaura De Rosa
Laura De Rosa
ASAntonio Salvati
Antonio Salvati
NMNicola Martini
Nicola Martini
DCDante Chiappino
Dante Chiappino
SCSimone Cappelli
Simone Cappelli
Francesco FaitaFrancesco Faita
Francesco Faita
Background & Aims: There is an unmet need for a reliable and reproducible non‐invasive measure of fatty liver content (FLC) for monitoring steatotic liver disease in clinical practice. Sonographic FLC assessment is qualitative and operator‐dependent, and the dynamic quantification range of algorithms based on a single ultrasound (US) parameter is unsatisfactory.This study aims to develop and validate a new multiparametric algorithm based on B‐mode images to quantify FLC using Magnetic Resonance (MR) values as standard reference.Methods: Patients with elevated liver enzymes and/or bright liver at US (N = 195) underwent FLC evaluation by MR and by US. Five US‐derived quantitative features [attenuation rate(AR), hepatic renal‐ratio(HR), diaphragm visualization(DV), hepatic‐portal‐vein‐ratio(HPV), portal‐vein‐wall(PVW)] were combined by mixed linear/exponential regression in a multiparametric model (Steatoscore2.0). One hundred and thirty‐four subjects were used for training and 61 for independent validations; score‐computation underwent an inter‐operator reproducibility analysis.Results: The model is based on a mixed linear/exponential combination of 3 US parameters (AR, HR, DV), modelled by 2 equations according to AR values. The computation of FLC by Steatoscore2.0 (mean ± std, 7.91% ± 8.69) and MR (mean ± std, 8.10% ± 10.31) is highly correlated with a low root mean square error in both training/validation cohorts, respectively (R = 0.92/0.86 and RMSE = 5.15/4.62, p < .001). Steatoscore2.0 identified patients with MR‐FLC≥5%/≥10% with sensitivity = 93.2%/89.4%, specificity = 86.1%/95.8%, AUROC = 0.958/0.975, respectively and correlated with MR (R = 0.92) significantly (p < .001) better than CAP (R = 0.73).Conclusions: Multiparametric Steatoscore2.0 measures FLC providing values highly comparable with MR. It is reliable, inexpensive, easy to use with any US equipment and qualifies to be tested in larger, prospective studies as new tool for the non‐invasive screening and monitoring of FLC.

13 June 2025 in Information
Verified
Journal Article
Open access
PDF file
Laura De RosaLaura De Rosa
Laura De Rosa
SLSerena L'Abbate
Serena L'Abbate
ESEduarda Mota da Silva
Eduarda Mota da Silva
MAMauro Andretta
Mauro Andretta
EBElisabetta Bianchini
Elisabetta Bianchini
Francesco FaitaFrancesco Faita
Francesco Faita
Background: Atherosclerotic disease is the leading global cause of death, driven by progressive plaque accumulation in the arteries. Ultrasound (US) imaging, both conventional (CUS) and intravascular (IVUS), is crucial for the non-invasive assessment of atherosclerotic plaques. Deep learning (DL) techniques have recently gained attention as tools to improve the accuracy and efficiency of image analysis in this domain. This paper reviews recent advancements in DL-based methods for the segmentation, classification, and quantification of atherosclerotic plaques in US imaging, focusing on their performance, clinical relevance, and translational challenges. Methods: A systematic literature search was conducted in the PubMed, Scopus, and Web of Science databases, following PRISMA guidelines. The review included peer-reviewed original articles published up to 31 January 2025 that applied DL models for plaque segmentation, characterization, and/or quantification in US images. Results: A total of 53 studies were included, with 72% focusing on carotid CUS and 28% on coronary IVUS. DL architectures, such as UNet and attention-based networks, were commonly used, achieving high segmentation accuracy with average Dice similarity coefficients of around 84%. Many models provided reliable quantitative outputs (such as total plaque area, plaque burden, and stenosis severity index) with correlation coefficients often exceeding R = 0.9 compared to manual annotations. Limitations included the scarcity of large, annotated, and publicly available datasets; the lack of external validation; and the limited availability of open-source code. Conclusions: DL-based approaches show considerable promise for advancing atherosclerotic plaque analysis in US imaging. To facilitate broader clinical adoption, future research should prioritize methodological standardization, external validation, data and code sharing, and integrating 3D US technologies.

15 November 2022 in The International Journal of Lower Extremity Wounds
Verified
Journal Article
Closed access
IFIlenia Foffa
Ilenia Foffa
AJAgata Janowska
Agata Janowska
MFMarco Fabbri
Marco Fabbri
PLPaola Losi
Paola Losi
ECElena Ciabatti
Elena Ciabatti
GSGiorgio Soldani
Giorgio Soldani
Treatment of chronic leg ulcers remains a major challenge and it is a substantial financial burden on individuals, families, caregivers, and health care system. There is increasing evidence on using of autologous Platelet-rich-plasma in wound repair but limited clinical data are available on the efficacy and safety of the use of umbilical cord blood platelet gel (CBPG). In our pilot study, for the first time, we aimed to evaluated the safety and efficacy of the use of umbilical CBPG combined with a hydrogel dressing in 10 patients with chronic venous ulcers (VU). The protocol consisted of application of umbilical cord blood platelet-rich plasma (PRP) combined with a Carboxymethyl cellulose (CMC)-based hydrogel dressing once a week for 4 weeks. The 80% of patients after 4 weeks of treatment had a significantly decrease in wound size. Moreover, we obtained an improvement in terms of mean Wound Bed Score (WBS), numeric rating scale (NRS) value and the EQ-5D index score. This pilot study showed that the topically therapeutic administration of umbilical CBPG associated with a CMC-based hydrogel dressing has the potential to accelerate the healing of chronic lesions without adverse reaction. However, additional studies with larger sample size and longer follow-up periods are required to confirm our findings.

27 September 2021
Verified
Book Chapter
Closed access
PDF file
SCSara Colantonio
Sara Colantonio
ASAntono Salvati
Antono Salvati
CCClaudia Caudai
Claudia Caudai
Ferruccio BoninoFerruccio Bonino
Ferruccio Bonino
Laura De RosaLaura De Rosa
Laura De Rosa
Francesco FaitaFrancesco Faita
Francesco Faita

15 November 2023 in Viruses
Verified
Journal Article
Open access
PDF file
DCDaniela Cavallone
Daniela Cavallone
EOEric David Bicaldo Ornos
Eric David Bicaldo Ornos
GRGabriele Ricco
Gabriele Ricco
FOFilippo Oliveri
Filippo Oliveri
BCBárbara Coco
Bárbara Coco
Maurizia Rossana BrunettoMaurizia Rossana Brunetto
Maurizia Rossana Brunetto
MiRNAs circulating in whole serum and HBsAg-particles are differentially expressed in chronic hepatitis B (CHB) and HBeAg-negative-HBV infection (ENI); their profiles are unknown in chronic hepatitis D (CHD). Serum- and HBsAg-associated miRNAs were analyzed in 75 subjects of 3 well-characterized groups (CHB 25, CHD 25, ENI 25) using next-generation sequencing (NGS). Overall miRNA profiles were consonant in serum and HBsAg-particles but significantly different according to the presence of hepatitis independently of Hepatitis D Virus (HDV)-co-infection. Stringent (Bonferroni Correction < 0.001) differential expression analysis showed 39 miRNAs upregulated in CHB vs. ENI and 31 of them also in CHD vs. ENI. miRNA profiles were coincident in CHB and CHD with only miR-200a-3p upregulated in CHB. Three miRNAs (miR-625-3p, miR-142-5p, and miR-223-3p) involved in immune response were upregulated in ENI. All 3 hepatocellular miRNAs of MiR-B-Index (miR-122-5p, miR-99a-5p, miR-192-5p) were overexpressed in both CHB and CHD patients. In conclusion, CHD and CHB patients showed highly similar serum miRNA profiling that was significantly different from that of individuals with HBeAg-negative infection and without liver disease.