Lawal Daura

Dr. Lawal Daura

University of Hertfordshire, Hatfield, Hertfordshire, UK

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2020 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Open access
LDLawal Daura
Lawal Daura
Gui-Yun TianGui-Yun Tian
Gui-Yun Tian
QYQiuji Yi
Qiuji Yi
ASAli Sophian
Ali Sophian
Eddy current testing (ECT) has been employed as a traditional non-destructive testing and evaluation (NDT&E) tool for many years. It has developed from single frequency to multiple frequencies, and eventually to pulsed and swept-frequency excitation. Recent progression of wireless power transfer (WPT) and flexible printed devices open opportunities to address challenges of defect detection and reconstruction under complex geometric situations. In this paper, a transmitter–receiver (Tx–Rx) flexible printed coil (FPC) array that uses the WPT approach featuring dual resonance responses for the first time has been proposed. The dual resonance responses can provide multiple parameters of samples, such as defect characteristics, lift-offs and material properties, while the flexible coil array allows area mapping of complex structures. To validate the proposed approach, experimental investigations of a single excitation coil with multiple receiving coils using the WPT principle were conducted on a curved pipe surface with a natural dent defect. The FPC array has one single excitation coil and 16 receiving (Rx) coils, which are used to measure the dent by using 21 C-scan points on the dedicated dent sample. The experimental data were then used for training and evaluation of dual resonance responses in terms of multiple feature extraction, selection and fusion for quantitative NDE. Four features, which include resonant magnitudes and principal components of the two resonant areas, were investigated for mapping and reconstructing the defective dent through correlation analysis for feature selection and feature fusion by deep learning. It shows that deep learning-based multiple feature fusion has outstanding performance for 3D defect reconstruction of WPT-based FPC-ECT. This article is part of the theme issue ‘Advanced electromagnetic non-destructive evaluation and smart monitoring’.

24 July 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
LDLawal Daura
Lawal Daura
Gui-Yun TianGui-Yun Tian
Gui-Yun Tian

25 August 2022 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
LDLawal Daura
Lawal Daura
Gui-Yun TianGui-Yun Tian
Gui-Yun Tian
Unavoidably, rolling contact fatigue (RCF) causes natural crack formation in the railhead, leading to rupture. Eddy current testing (ECT) is commonly used to quantify RCF cracks because of its higher sensitivity to a surface flaw, though with limited feature points. This article aims to characterize inclined angular RCF crack parameters in a rail-line material via a modified topology of Wireless Power Transfer (WPT)-based ECT (WPTECT) due to its magnetically coupled resonant for excitation and sensing circuits and utilize multiple resonance responses compared to other ECT. We experimentally designed and evaluated WPTECT and extracted multiple resonances and principal components analysis features to characterize inclined angular RCF cracks. The response minima point feature quantified the crack parameters incomparably; however, the second resonance feature is better than the first resonance. The reconstructed depth, opening width, and angle of the RCF cracks have a maximum correlation, R 2 value of 96.4%, 93.1%, and 79.1%, respectively, and root mean square error of 0.05 mm, 0.08 mm, and 6.6°, respectively.

26 July 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
EIEmmanuel Tashiwa Ibrahim
Emmanuel Tashiwa Ibrahim
CYChangrong Yang
Changrong Yang
Gui-Yun TianGui-Yun Tian
Gui-Yun Tian
MRMark Robinson
Mark Robinson
QMQiuping Ma
Qiuping Ma
LDLawal Daura
Lawal Daura
It is of great importance to improve the spatial resolution and sensitivity of magnetic flux leakage (MFL) sensors for small cracks characterisation on pipelines. To solve these problems, a novel pulsed magnetic flux leakage (PMFL) method, using magnetic head (MH) and a side placement of tunnelling magnetoresistance (TMR) is proposed. Two symmetrically inclined magnetic cores with a tiny air gap opening form a small detection region, making PMFL focus in that area. The side placement of the TMR ensures a reduction of noise and lift-off influence. A series of comparative tests with different kinds of artificial and natural cracks have been used to verify the high spatial resolution and sensitivity of the proposed method. The higher signal-to-noise ratio (SNR) and sensitivity of the side placement TMR were verified by two-dimensional (2D) and three-dimensional (3D) magnetic maps corresponding to the natural crack. The SNR and sensitivity of the side placement of TMR is greater than that of the under placement by an average of 41% and 160% respectively.

31 March 2025 in Nondestructive Testing and Evaluation
Verified
Journal Article
Open access
LDLawal Daura
Lawal Daura
Monika RoopakMonika Roopak
Monika Roopak
Gui-Yun TianGui-Yun Tian
Gui-Yun Tian
SPSimon Parkinson
Simon Parkinson
XCXiaotian Chen
Xiaotian Chen
EIEmmanuel Tashiwa Ibrahim
Emmanuel Tashiwa Ibrahim

15 May 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
LDLawal Daura
Lawal Daura
Yichuang SunYichuang Sun
Yichuang Sun
Gui-Yun TianGui-Yun Tian
Gui-Yun Tian
EIEmmanuel Tashiwa Ibrahim
Emmanuel Tashiwa Ibrahim
Monika RoopakMonika Roopak
Monika Roopak
CYChangrong Yang
Changrong Yang
Electromagnetic sensors’ response is affected by lift-off variations, which are caused by nonmagnetic coating thickness, surface roughness or sensor vibrations. These variations affect eddy current testing (ECT) sensitivity, defect quantification and reconstruction of material properties. This paper compares different magnetic resonance circuit (MRC) topologies as signal conditioning for improving ECT system response to various lift-offs. The MRC is designed to operate at maximum energy, with the potential of several resonances, which lead to enhanced response for optimal and multiple feature extraction, improving signal-to-noise ratio (SNR) and increasing sensitivity to cracks. The proposed paper designs and investigates the effect of different MRC topologies connected to ECT systems to inspect a steel block with surface cracks. The performance comparison of the proposed systems provides the advantages and limitations of different MRC approaches for multiple resonance potentials, higher SNR and response sensitivity at different lift-off distances. The advanced MRC, featuring series and shunt topologies in each transmit and receive coil, is the most immune to noise, with an SNR of 49.9 dB at a 3.4 mm lift-off using its first peak frequency feature. Its response is less crack-sensitive, with a sensitivity of up to 1.5% at 0.6 mm lift-off.