This paper presents a new method for reducing the total harmonic distortion (THD) of photovoltaic (PV) systems by using an adaptive filter based on a predictive model. Instead of reducing the produced THD at each stage of the PV system, a one-step process is implemented at the end stage. The connection topology of the adaptive filter is similar to normal active and passive filters. The main difference is its ability to adjust the filtering coefficients while others cannot. The proposed method is applied to a single-phase standalone PV system by adopting least mean square (LMS), normalized LMS (NLMS) and leaky LMS algorithms to verify the validity of the proposed method. Various values of filter length and step size are evaluated, and results indicate that the proposed method can reduce THD in the current signal of the PV system significantly by using all of the mentioned algorithms. Different step sizes and filter lengths directly influence the effectiveness of the THD reduction, with small step sizes and long filters being the most effective. Amongst the algorithms, NLMS reduces THD the most, and LMS reaches the peak current value the fastest.
Total harmonics distortion (THD) is one of the main problems in power systems due to its effects in generating undesirable issues in power quality. These effects include heating (in transformers, capacitors, motors, and generators), disoperation of electronic equipment, incorrect readings on meters, disoperation of protective relays, and communication interference. Besides these problems, harmonics affect the power quality in both transmission and distribution systems. Different techniques have been used to mitigate the effects of harmonics. These techniques include; passive filters, active power filter, artificial intelligent, and adaptive selective harmonics reductions. Each method has some advantages and disadvantages. This paper presented new models of total harmonics distortion reduction using adaptive, Weiner, and Kalman filters. In order to test the performance of the presented methods, the output current of a single phase inverter circuit was used as a study case. The new models reduced the total harmonics distortion from by more than 50% however Kalman filters give the best performance as compared to adaptive and Weiner filters.
This paper presents a novel method to reduce the Total Harmonics Distortion (THD) using adaptive filters. Least Mean Square (LMS) and Normalized Lest Mean Square (NLMS) were used as adaptation algorithms. Both of these algorithms gave a very good performance in terms of distortion reduction. Instead of focusing on specific harmonics as in other methods of adaptive filtering, this method targets all the harmonics contained in the signal for elimination. A single phase inverter was used as a study case to test the performance of the proposed technique. The obtained results showed that the presented method can decrease the total harmonics distortion dramatically over time.
16 October 2018 in Periodicals of Engineering and Natural Sciences (PEN)