Luis Antonio Yataco Pastor

Mr. Luis Antonio Yataco Pastor

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2026 in Technologies
Verified
Journal Article
Open access
PDF file
Luis Antonio Yataco PastorLuis Antonio Yataco Pastor
Luis Antonio Yataco Pastor
Yoisdel CastilloYoisdel Castillo
Yoisdel Castillo
Reinier Jiménez BorgesReinier Jiménez Borges
Reinier Jiménez Borges
Marcos AvilesMarcos Aviles
Marcos Aviles
Luis Angel Iturralde CarreraLuis Angel Iturralde Carrera
Luis Angel Iturralde Carrera
Juvenal RodriguezJuvenal Rodriguez
Juvenal Rodriguez
Archimedes screw turbines (ASTs) are a well-established technology for low-head micro-hydropower generation, whose performance is highly sensitive to the radial clearance between the helical blade and the casing. In engineering practice, manufacturing and assembly tolerances frequently result in realized (as-built) clearances larger than the optimal design (as-designed) value; however, the literature lacks a quantitative assessment of how this discrepancy affects the performance curve and the position of the best efficiency point (BEP). This study numerically investigates a 1.0 m3/s, 2.1 m head AST in a closed tubular configuration, adopting a 15.00 mm radial clearance that exceeds the analytical optimum (6.36 mm) by 136% as a worst-case construction scenario, representative of both relaxed manufacturing tolerances and severe diametral wear. A three-dimensional, transient, multiphase CFD model (RANS SST k–ω with a volume-of-fluid free-surface formulation) is applied over six flow-rate conditions (0.55–2.00 m3/s) at constant rotational speed, with mesh independence verified using the Grid Convergence Index. At the nominal design flow rate, the overall efficiency decreases to 65.0%, 18 percentage points below the leakage-limited prediction of the one-dimensional model for the same clearance (83.3%) and 28 points below the ideal design (93.0%), i.e., a penalty nearly three times the one-dimensional estimate. The fitted best efficiency point shifts to 1.44±0.27 m3/s (95% CI), approximately 44% above the design flow rate, with an interpolated maximum efficiency of 66.0%; the efficiency plateau (η≥ηmax−1 pp) spans 1.16–1.72 m3/s and excludes the design flow rate, whereas the fixed-speed one-dimensional model predicts a shift of only +10% by volumetric compensation of the leakage. The discrepancy with the analytical model is attributed to two mechanisms: turbulent dissipation of the leakage jet and, more importantly, the internal nature of overfilling in a closed casing, where excess flow recirculates above the shaft and is retained by the machine rather than being treated as a terminal loss. The discharge also exhibits pulsatile behavior at the rotational frequency (0.52 Hz), with a relative amplitude that decreases from 43% to 29% of the mean torque over the simulated range, with a secondary local maximum near the best efficiency point, carrying direct implications for shaft fatigue design. The study is an exploratory numerical investigation whose predictions constitute testable hypotheses for experimental validation; these findings demonstrate that radial-clearance manufacturing tolerances require an operational reclassification of the intake flow rate and provide criteria for incorporating clearance effects into the design and long-term planning of low-head micro-hydropower projects.

11 August 2026 in Water
Verified
Journal Article
Open access
PDF file
GTGeorge Anthony Trigueros
George Anthony Trigueros
Luis Antonio Yataco PastorLuis Antonio Yataco Pastor
Luis Antonio Yataco Pastor
DADicarlo Stefano Romani Arbieto
Dicarlo Stefano Romani Arbieto
Yoisdel CastilloYoisdel Castillo
Yoisdel Castillo
Reinier Jiménez BorgesReinier Jiménez Borges
Reinier Jiménez Borges
Juvenal RodriguezJuvenal Rodriguez
Juvenal Rodriguez
Long-term influent flow projection governs the sizing of wastewater treatment plants (WWTPs), yet conventional practice estimates future flows using per capita generation rates and coefficients assumed to remain constant over time, neglecting the fact that, in urbanizing catchments, the fraction of generated wastewater that reaches the treatment plant increases as the sewer network expands and densifies. This study develops and validates an explicit-structure model that separates demographic wastewater generation from hydraulic conveyance, disaggregates the service area into fully contributing and partially contributing sectors, and introduces a time-dependent transport coefficient, k(t). Applied to the La Chira WWTP (Lima, Peru; approximately 2.6 million inhabitants), the model was evaluated through leave-one-year-out cross-validation against both a static transport model and an aggregated formulation. The proposed formulation consistently outperformed the alternatives in out-of-sample prediction (Nash–Sutcliffe efficiency of 0.965 and mean absolute percentage error of 1.88%, compared with 0.825 and 0.799 for the benchmark models), providing falsifiable evidence of the value of spatial disaggregation and time-varying transport representation. The transport coefficient increases from 0.491 in 2017 to 0.813 in 2040 under the linear reference specification, with a logistic alternative—statistically indistinguishable in calibration—bounding the projection from below; a formal Shapley decomposition attributes 44% of the projected flow increase to this coefficient. The observed flow rate in 2025 (7.341 m3 s−1) provides an external validation point, predicted with a relative error of 0.7%. Mean influent flow is projected to reach 10.12 m3 s−1 by 2040 (95% CI: 8.55–11.69), representing a 61% increase above the design average flow and approaching the design peak capacity (11.3 m3 s−1), with an exceedance probability of the annual mean of approximately 5%. These results indicate a progressive approach to hydraulic saturation within the planning horizon. The proposed framework is robust to alternative per capita generation assumptions, mechanistically grounded, interpretable, and transferable to sanitation systems characterized by evolving coverage and network connectivity.

10 November 2026 in Urban Science
Verified
Journal Article
Open access
PDF file
Luis Antonio Yataco PastorLuis Antonio Yataco Pastor
Luis Antonio Yataco Pastor
Ana Cristina Ybaceta ValdiviaAna Cristina Ybaceta Valdivia
Ana Cristina Ybaceta Valdivia
José M. Álvarez-AlvaradoJosé M. Álvarez-Alvarado
José M. Álvarez-Alvarado
Yoisdel CastilloYoisdel Castillo
Yoisdel Castillo
Reinier Jiménez BorgesReinier Jiménez Borges
Reinier Jiménez Borges
Juvenal RodriguezJuvenal Rodriguez
Juvenal Rodriguez
Flash floods and debris flows in Andean–Amazonian mountain catchments rank among the most destructive natural hazards, and the headwater catchments where they originate almost invariably lack hydrometric records, placing them within the classical problem of Predictions in Ungauged Basins (PUB). Hazard maps generated for these environments from open data share a critical weakness: they are released without empirical validation against observed events, so their credibility rests on unverified assumptions. This study proposes OF-VAL (Open-data Flood Hazard Framework with Historical VALidation), a six-stage framework based entirely on open-access data whose distinguishing feature is a validation gate: hazard products are released only if the model, forced with an open-data reconstruction of a documented historical event, reproduces the observed impact footprint above a predefined threshold (F≥0.50). The framework is demonstrated in the ungauged Sicre–Ipal microcatchment (Cusco, Peru; 19.41 km2), using as benchmark the debris flow of 21 December 2018 documented by INGEMMET and delineated on 0.7 m PeruSAT-1 imagery. A process-class compatibility rule (R1.4) screens the benchmark before gate execution: the event’s documented genesis as a landslide-dam outburst, together with four concordant open-data estimates of the event rainfall (6.3 and 9.7 mm day−1 at the two governing SENAMHI stations, 7.5 mm at the PISCOpd cell and 18.2 mm in GPM IMERG, all an order of magnitude below debris-flow triggering thresholds), establishes that the flow was not pluvially generated; the reconstruction executed with the largest of these estimates wets at most 5.6 ha against a 15.5 ha deposit, so the fit index is bounded at F≤0.36 and gate G4a is declared not executable with this benchmark. During revision, a volume-consistency audit of the design-storm chain revealed that extending the fitted Bell–IDF relationships to the 6 h design duration produced storm volumes exceeding the 24 h quantiles by 48–129%; the design hydrology was therefore rebuilt with the volume-restricted Dyck–Peschke parameterization (P6h=0.7071P24h) over the two station series satisfying all qualification rules (Quillabamba and Machu Picchu). Three further rules were added when the simulations were audited: runoff-volume consistency with the closed-form SCS excess (R4.4) and an outlet boundary at the channel invert (R4.5), which detected and corrected two defects of the previous runs, and the declaration of the fraction of runoff delivered to the outlet (R4.6). Under the corrected scenarios (return periods of 25–140 years), reported as non-validated diagnostic products, only 3.3–6.9 mm of the 61–76 mm areal design depths become excess runoff, and 70–80% of that excess is retained in closed depressions of the unconditioned 12.5 m terrain; the critical scenario wets 8.6 ha on the computational mesh, of which 1.2 ha reach FEMA High hazard or above and 2.9 ha are unsafe for people, with 0.25 ha wetted inside the settlement footprints of Sicre, Tablahuasi, and Pedregal. A gate taxonomy distinguishing blocking, release, and recording gates, and a rule-by-rule compliance table, document what was specified, what was executed, and the disposition of every deviation, including the numerical controls that the demonstration itself failed. The framework is reproducible and transferable to other ungauged catchments with documented events, and its planning-level products complement, rather than replace, site-specific topographic and geotechnical investigations.

13 March 2026 in Fluids
Verified
Journal Article
Open access
PDF file
Luis Antonio Yataco PastorLuis Antonio Yataco Pastor
Luis Antonio Yataco Pastor
Ana Cristina Ybaceta ValdiviaAna Cristina Ybaceta Valdivia
Ana Cristina Ybaceta Valdivia
Yoisdel CastilloYoisdel Castillo
Yoisdel Castillo
Reinier Jiménez BorgesReinier Jiménez Borges
Reinier Jiménez Borges
Luis Angel Iturralde CarreraLuis Angel Iturralde Carrera
Luis Angel Iturralde Carrera
Juvenal RodriguezJuvenal Rodriguez
Juvenal Rodriguez
Energy dissipation in stepped weirs depends on the complex interaction between geometry, flow regime, and surface aeration. The research proposes a dimensionless empirical model (RE3T) to predict the overall energy dissipation in three-section stepped weirs with variable slopes. The formulation integrates dimensional analysis based on the Vaschy–Buckingham theorem, controlled physical experimentation, and three-dimensional numerical simulations using CFD employing the RANS–SST turbulence model implemented in ANSYS CFX. Eighteen numerical simulations were performed covering seven geometric configurations and four hydraulic inlet conditions, covering slug, transitional, and skimming flow regimes. The CFD model was previously validated by comparison with a physical scale model, obtaining a discrepancy of only 0.38% in relative energy dissipation. The validated dataset was then used to calibrate an empirical multiplicative correlation composed of eight dimensionless groups associated with sectional slopes, number of steps, overall geometric ratio, and upstream Froude number. The proposed model achieved a coefficient of determination R2 = 0.81, with relative errors generally less than 1% and a maximum deviation of 2.34%. The statistical indicators (RMSE, MAE, and bias) confirm the absence of significant systematic trends within the defined domain of validity. The results show that the Froude number and the slopes of the sections are the variables with the greatest influence on overall dissipation. The RE3T formulation is a physically consistent and computationally efficient predictive tool for the design and analysis of stepped weirs with variable slopes, extending the scope of traditional correlations developed for uniform slopes.

15 September 2026 in Hydrology
Verified
Journal Article
Open access
PDF file
Luis Antonio Yataco PastorLuis Antonio Yataco Pastor
Luis Antonio Yataco Pastor
Yoisdel CastilloYoisdel Castillo
Yoisdel Castillo
Reinier Jiménez BorgesReinier Jiménez Borges
Reinier Jiménez Borges
Marcos AvilesMarcos Aviles
Marcos Aviles
Omar Rodríguez AbreoOmar Rodríguez Abreo
Omar Rodríguez Abreo
Juvenal RodriguezJuvenal Rodriguez
Juvenal Rodriguez
Transverse modification of step geometry has been repeatedly proposed as a means of increasing energy dissipation in stepped spillways, with numerically reported gains ranging from 5.6% to 34.7% for labyrinth configurations, in unresolved contradiction with air–water experimental evidence that detects no measurable difference. The objective of this study is threefold: to verify whether the transverse alternation of the tread length increases the net energy dissipation of the coupled chute–stilling basin system, to quantify its effect on the kinematic and energetic state of the flow delivered to the terminal energy dissipator, and to delimit its domain of applicability. That premise is subjected to verification through 38 three-dimensional Reynolds-averaged Navier–Stokes (RANS) simulations (k–ω shear-stress transport (SST) closure, homogeneous volume-of-fluid (VOF) formulation) performed in ANSYS CFX 2025 R2, comparing a three-section stepped spillway with a uniform rectilinear footprint against a configuration with transverse L–L/2 alternation, under 19 geometric–hydraulic combinations spanning the nappe, transition, and skimming flow regimes (0.57≤dc/h≤2.93). The model was verified through a mesh-convergence analysis of the uniform configuration (grid convergence index, GCI =0.66%, on the approach depth) and validated against a physical scale model (0.38% discrepancy, exceeding the propagated experimental uncertainty); a three-level mesh study of the variable-tread configuration shows that its toe-flow response develops as the transverse tread strips become resolved and is not yet mesh-independent at the finest level, which is stated as a limitation of the quantitative results. Because the homogeneous multiphase formulation does not include an air-entrainment submodel, all results correspond to the modeled non-aerated flow conditions. The results do not support the hypothesis of a net dissipative gain: the global energy balance of the two topologies is equivalent within the numerical resolution of the study (bias +0.13 pp; root-mean-square error (RMSE) 0.26 pp), of the order of the discretization uncertainty of the study itself. The actual effect is a redistribution of the dissipative partition that conditions the flow delivered to the energy dissipator: the toe Froude number is reduced in all 19 paired cases (16.5–88.4%; mean: 34.1%). In nine scenarios the hydraulic jump is conditioned without being suppressed (Fr1 from 3.95–4.57 to 1.19–3.71), the energy delivered to the stilling basin drops by 18.3–57.9%, and the residual energy decreases by up to 14.98%; under subcritical toe flow, the same thickening increases the delivered energy by 12.3–19.4% and penalizes the residual energy by up to 18.08%; in two intermediate-discharge scenarios the jump is suppressed, yielding no benefit whatsoever. The transition is expressed through a critical threshold, nominally (dc/h)crit≈1.48 within the observed separation interval 1.44<dc/h<1.53: the thirteen resolvable scenarios preserve the predicted sign separation without exception. The variable footprint is not a dissipation intensifier but a chute–dissipator coupling element, applicable only to high relative discharges.