Lukas Steffen

Mr. Lukas Steffen

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2025 in Construction Materials
Verified
Journal Article
Open access
PDF file
LSLukas Steffen
Lukas Steffen
Ismael ViejoIsmael Viejo
Ismael Viejo
BHBelén Hernández
Belén Hernández
MSMario Stelzmann
Mario Stelzmann
Klaus HolschemacherKlaus Holschemacher
Klaus Holschemacher
Robert BöhmRobert Böhm
Robert Böhm
Textile-reinforced concrete (TRC) sandwich panels with lightweight cores are a promising solution for sustainable and slender building envelopes. However, their structural performance depends strongly on the shear connection between the outer shells. This study investigates the flexural behavior of TRC sandwich panels with glass fiber-reinforced polymer (GFRP) rod connectors under four-point bending. Three full-scale specimens were manufactured with high-performance concrete (HPC) face layers, an expanded polystyrene (EPS) core, and 12 mm GFRP rods as shear connectors. The panels were tested up to failure, with measurements of load–deflection behavior, crack development, and interlayer slip. Additionally, a linear-elastic finite element model was developed to complement the experimental campaign, capturing the global stiffness of the system and providing complementary insight into the internal stress distribution. The experimental results revealed stable load-bearing behavior with ductile post-cracking response. A degree of composite interaction of γ = 0.33 was obtained, indicating partially composite action. Slip measurements confirmed effective shear transfer by the GFRP connectors, while no brittle failure or connector rupture was observed. The numerical analysis confirmed the elastic response observed in the tests and highlighted the key role of the GFRP connectors in coupling the TRC shells, extending the interpretation beyond experimental results. Overall, the study demonstrates the potential of TRC sandwich panels with mechanical connectors as a safe and reliable structural solution.


31 July 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSMario Stelzmann
Mario Stelzmann
LSLukas Steffen
Lukas Steffen
TKThomas Klink
Thomas Klink
Klaus HolschemacherKlaus Holschemacher
Klaus Holschemacher
This paper presents an experimental investigation of a demountable hybrid timber–carbon-reinforced concrete (CRC) wall system with a reversible mechanical connection detail based on embedded transport anchors, screwed steel angle brackets, and full-thread screws. The study addresses a wall concept in which a thin externally mounted CRC plate contributes to lateral load transfer through discrete reversible connection points rather than through a bonded or cast-in-place composite interface. Four full-scale wall specimens were tested under horizontal shear loading and a nominal vertical preload of 92kN in an adapted in-plane shear test arrangement. The maximum horizontal loads ranged from 19.7 to 22.7kN, with a mean value of 21.2kN and a coefficient of variation of 5.9%. For the three specimens with complete displacement records, the head displacement at maximum load ranged from 33.7 to 45.8mm. The initial wall stiffness K0.05−0.15 ranged from 1.93 to 2.80kN/mm, whereas the stiffness evaluated between 0.2Fmax and 0.4Fmax ranged from 0.52 to 0.67kN/mm. Normalized to the reference width of the tested configuration, the maximum horizontal load was 15.8 to 18.2kN/m. Damage initiated locally in the CRC anchorage zones, especially at the corner anchors, and progressed from first cracking to local concrete spalling. The governing failure mode was local concrete failure in the anchorage zones, accompanied by deformation of the steel angle brackets, while no critical damage was observed in the timber joints. The results demonstrate the feasibility of the investigated reversible timber–CRC connection concept for transferring in-plane shear forces in the tested configuration, but further tests are required before general design recommendations can be derived.

29 January 2026 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
PVPamela Voigt
Pamela Voigt
MSMario Stelzmann
Mario Stelzmann
Robert BöhmRobert Böhm
Robert Böhm
LSLukas Steffen
Lukas Steffen
Hannes Franz Maria PellerHannes Franz Maria Peller
Hannes Franz Maria Peller
Costas CharitidisCostas Charitidis
Costas Charitidis
The thermally efficient and lightweight TRC/CLCi composite panels for functional and smart building envelopes, funded by the iclimabuilt project (Grant Agreement no. 952886), offer innovative solutions to sustainably address common failure risks in facade systems. This work specifically emphasizes strategies for mitigating structural, thermal, and fire-related failures through targeted material selection, advanced design methodologies, and rigorous validation protocols. To effectively mitigate structural failures, high-pressure concrete (HPC) reinforced with carbon fibers is utilized, significantly enhancing tensile strength, reducing susceptibility to cracking, and improving overall durability. To counteract thermal bridging—a critical failure mode compromising energy efficiency and structural integrity—the panels employ specially designed glass-fiber reinforced pins connecting HPC outer layers through the cellular lightweight concrete (CLC) insulation core that has a density of around 70 kg/m3 and a thermal conductivity in the range 35 mW/m∙K comparable to those of expanded polystyrene and Rockwool. These connectors ensure effective load transfer and maintain optimal thermal performance. A central focus of the failure mitigation strategy is robust fire behavior. The developed panels undergo rigorous standardized fire tests, achieving an exceptional reaction to fire classification of A2. This outcome confirms that HPC layers maintain structural stability and integrity even under prolonged fire exposure, effectively preventing catastrophic failures and ensuring occupant safety. In conclusion, this work highlights explicit failure mitigation strategies—reinforced concrete materials for structural stability, specialized glass-fiber connectors to prevent thermal bridging, rigorous fire behavior protocols, and comprehensive thermal performance validation—to produce a facade system that is robust, energy-efficient, fire-safe, and sustainable for modern buildings.