Background: The natural history of tricuspid valve regurgitation (TR) is characterized by poor prognosis and high in-hospital mortality when treated with isolated surgery. We report the preliminary echocardiographic and procedural results of a prospective cohort of symptomatic patients with high to prohibitive surgical risk and at least severe TR who underwent transcatheter edge-to-edge repair through the TriClipTM system. Methods: From June 2020 to March 2022, 27 consecutive patients were screened, and 13 underwent transcatheter TriClipTM repair. In-hospital, 30-day and six-month clinical and echocardiographic outcomes were collected. Results: Nine patients had severe, three massive and one baseline torrential TR. Sustained TR reduction of ≥1 grade was achieved in all patients, of which 90% reached a moderate TR or less. On transthoracic echocardiographic examination, there were significant reductions in vena contracta width (p < 0.001), effective regurgitant orifice area (p < 0.001) and regurgitant volume (p < 0.001) between baseline and hospital discharge. We also observed a significant reduction in tricuspid annulus diameter (p < 0.001), right ventricular basal diameter (p = 0.001) and right atrial area (p = 0.026). Conclusion: Treatment with the edge-to-edge TriClip device is safe and effective. The resulting echocardiographic improvements indicate tricuspid valve leaflet approximation does not just significantly reduce the grade of TR but also affects adjacent structures and improves right ventricular afterload adaptation.
Transcatheter aortic valve implantation (TAVI) improves event-free survival in patients with severe aortic stenosis, but patients’ exercise capacity remains poor after the procedure. Therefore, we sought to compare the effects of a supervised center-based exercise training program and unsupervised exercise routine on exercise capacity and vascular function in patients after TAVI. Patients were randomized to either center-based exercise training (12–24 sessions of combined aerobic and low-weight resistance training twice weekly for 8–12 weeks) or an unsupervised home-based exercise routine (initial appraisal with detailed recommendations and monthly follow-up). Exercise capacity (cardiopulmonary testing) and vascular function (ultrasonographic measurement of flow-mediated vasodilation (FMD) and arterial stiffness) were assessed at the baseline and after the study period. We included 23 patients (mean age of 81 years, 61% women), with higher-than-expected drop-out rates (41%) because of the coronavirus-19 pandemic outbreak. Exercise capacity improved over time, irrespective of the intervention group: 0.09 mL/min/kg increase in peak oxygen uptake (95% CI [0.01–0.16]; p = 0.02), 8.2 Watts increase in workload (95% CI [0.6–15.8]; p = 0.034), and 47 s increase in cumulative exercise time (95% CI [5.0–89.6]; p = 0.029). A between-group difference in change over time (treatment effect) was detected only for FMD (4.49%; 95% CI [2.35; 6.63], p < 0.001), but not for other outcome variables. Both supervised and unsupervised exercise training improve exercise capacity and vascular function in patients after TAVI, with supervised exercise training possibly yielding larger improvements in vascular function, as determined by FMD.
Background: Computed tomography (CT) is the recommended imaging technique for defining the anatomical suitability for current transcatheter technologies and planning tricuspid valve (TV) intervention. The aim of the Tricuspid Regurgitation IMAging (TRIMA) study was to assess the geometrical characteristics of the TV complex using novel CT parameters. Methods: This prospective, single-center study enrolled 22 consecutive patients with severe tricuspid regurgitation, who underwent a cardiac CT study dedicated to the right chambers. The following variables were obtained: annulus area and perimeter, septal-lateral and antero-posterior diameters, tenting height, and anatomical regurgitant orifice area. Moreover, the following novel annular parameters were assessed: distance between commissures, distance between TV centroid and commissures, and angles between centroid and commissures. Results: A significant phasic variability during the cardiac cycle existed for all variables except for eccentricity, angles, and distance between the postero-septal and antero-posterior commissure and distance between the centroid and antero-posterior commissure. There was a significant relationship between the TV annulus area and novel annular parameters, except for annular angles. Additionally, novel annular variables were found to predict the annulus area. Conclusions: These novel additional variables may provide an initial platform from which the complexity of the TV annular morphology can continue to be better understood for further improving transcatheter therapies.
2 January 2026 in Frontiers in Cardiovascular Medicine
Background: The expanding role of transcatheter aortic valve implantation (TAVI) highlights the need to identify factors influencing long-term outcomes. Systemic inflammatory response syndrome (SIRS) is a frequent post-procedural event that may adversely affect prognosis. Measurement of inflammatory biomarkers may improve the understanding of underlying mechanisms and refine patient risk stratification. Methods: This single-center, prospective cohort study, enrolled 62 consecutive patients undergoing TAVI, who were followed for up to 5 years. Blood samples were collected before TAVI, at 24 h and 3–6 months post-procedure. Changes in biomarker levels, predictors of SIRS, and inflammatory predictors of long-term outcomes were analyzed. Results: SIRS developed in 45% of patients. Significant temporal changes were observed in hs-CRP, TNF-α, sST2/IL-33, IL-10, and IL-2 levels, irrespective of baseline or procedural characteristics. The development of SIRS was associated with a higher risk of all-cause mortality or unplanned hospitalization at 5 years (HR 3.07, 95% CI 1.57–6.00; p = 0.001). Baseline hs-CRP (HR 1.21, 95% CI 1.09-1.35; p < 0.001) and IFN-γ (HR 1.22; 95% CI 1.09–1.36; p < 0.001) levels were predictive of adverse outcomes. In multivariable Cox analysis, these associations remained, though findings should be interpreted cautiously given the limited sample size. Conclusions: SIRS is a common post-TAVI phenomenon and may be linked to long-term outcomes. Elevated pre-procedural hs-CRP and IFN- γ levels were associated with higher risk for adverse events, suggesting they may serve as exploratory biomarkers for risk stratification in this population.
Background: Degenerative aortic stenosis is an atherosclerotic-like process associated with impaired endothelial and autonomic function. Transcatheter aortic valve implantation (TAVI) has become a treatment of choice for patient with severe degenerative aortic stenosis at high surgical risk. The effect of this procedure on endothelial function measured with flow mediated dilatation (FMD) and autonomic function measured with heart rate variability (HRV) at different time-points of disease management (early and late follow-up) remains unknown. Methods: We prospectively included 50 patients with severe aortic stenosis who were deemed suitable for TAVI by the Heart Team. FMD and HRV parameters were collected at baseline (<24 h pre-TAVI), at early follow-up (up to 48 h post-TAVI) and at late follow-up (3–6 months post-TAVI). Results: 43 patients (mean age 81 (75–85); 60% women) completed the study. FMD significantly improved from 2.8 ± 1.5% before TAVI to 4.7 ± 2.7% early after TAVI (p < 0.001) and was later maintained on late follow-up (4.8 ± 2.7%, p = 0.936). Conversely, high-resolution ECG parameters remained preserved at early and improved at late follow-up after TAVI. Significant improvement was detected in a high frequency-domain parameter—HF (from 5231 ± 1783 to 6507 ± 1789 ms2; p = 0.029) and in two Poincare plot parameters: ratio of the short- and long-term R-R variability in the Poincare plot—SD1/SD2 (from 0.682 to 0.884 ms2; p = 0.003) and short-term R-R variability in the Poincare plot—SDRR (from 9.6 to 23.9 ms; p = 0.001). Echocardiographic parameters comprising baseline maximal aortic valve velocity (R = 0.415; p = 0.011), mean aortic gradient (R = 0.373; p = 0.018), indexed stroke volume (R = 0.503; p = 0.006), change in aortic valve maximal velocity (R = 0.365; p = 0.031), change in mean aortic gradient (R = 0.394; p = 0.019) and NT-proBNP (R = 0.491; p = 0.001) were found as significant predictors of change in FMD. Conclusions: Endothelial function measured with FMD and autonomic function obtained with HRV parameters significantly improve after TAVI. While endothelial function improves early and is maintained later after TAVI, autonomic function remains stable and improves on late follow-up. This is most likely caused by early hemodynamic changes after resolution of aortic valve obstruction and gradual left ventricular remodeling. Clinical Trial Registration: www.clinicaltrials.gov, identifier NCT04286893.
10 August 2023 in Frontiers in Cardiovascular Medicine
Background: Aortic regurgitation is a major concern following transcatheter aortic valve implantation (TAVI), as even low-grade regurgitation is associated with increased mortality. This is of particular concern to patients with pre-existing aortic disease who are at increased risk of TAVI valve slippage. Furthermore, conduction system disturbances after TAVI, namely left bundle branch block (LBBB), may have an additional detrimental effect on cardiac function.Case presentation: This report documents a successful treatment strategy in a frail patient with a bicuspid aortic valve and aortic disease after valve-sparing surgical repair in 1998, who subsequently developed aortic stenosis and underwent TAVI with an Evolut R self-expanding aortic valve. The progression of aortic disease, aortic root dilatation, and leaflet degeneration over the following years caused aortic regurgitation of the self-expanding aortic valve, resulting in left ventricular dilatation and heart failure along with LBBB and left ventricular (LV) mechanical dyssynchrony. Diagnostic workup of the patient showed persistence of the aneurysm distal to the graft with a dissection spanning the ascending aorta, arch, and terminating proximal to the aortic isthmus. After consideration by the cardiac team, a balloon-expandable valve was chosen for a valve-in-valve (ViV) procedure to provide sufficient radial force to expand the existing valve and correct the regurgitation. Due to the anatomy, a J-wire and pigtail catheter were successfully used for a safe approach and placement of the valve. Following the procedure, intermittent complete atrioventricular block was observed in addition to the pre-existing left bundle branch block, necessitating resynchronization pacing. Due to anatomical considerations, ease of placement, and the expected good level of resynchronization due to the proximal block, we opted for left bundle branch pacing, which showed improvement in left ventricular dyssynchrony and LV function at follow-up.Conclusion: Valve-in-valve implantation of a balloon-expandable Myval TAVI device to treat aortic regurgitation caused by slippage and right leaflet disfunction of slef valve is feasible in challenging anatomical scenarios. Left bundle branch pacing is a viable alternative to correct mechanical dyssynchrony in complex patients with LBBB and anatomical challenges necessitating resynchronization.
About Me
Interventional cardiologist at University Medical Centre of Ljubljana.
Assistant at Medical Faculty, University of Ljubljana.
Interventional cardiologist at University Medical Centre of Ljubljana.
Assistant at Medical Faculty, University of Ljubljana.