MOHAMMED EL HOSENY

Mr. MOHAMMED EL HOSENY

Xi'an Jiaotong University, China
+1
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2022 in Soil Dynamics and Earthquake Engineering
Verified
Journal Article
Closed access
MHMOHAMMED EL HOSENY
MOHAMMED EL HOSENY
JMJianxun Ma
Jianxun Ma
WDWalid Dawoud
Walid Dawoud
DFDavide Forcellini
Davide Forcellini

24 January 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
MHMOHAMMED EL HOSENY
MOHAMMED EL HOSENY
JMJianxun Ma
Jianxun Ma
JMJosephine Musanyufu
Josephine Musanyufu
The dynamic soil-structure interaction is a combination of phenomena caused by the flexibility of soil foundation in structure response. The structure response may be changed by embedded basement stories. Thus, this study seeks to assess the dynamic response of seven-story concrete frame type buildings without a basement, one basement story, and two basement stories, considering fixed and flexible bases. For this purpose, the experimental tests on the small shaking table were executed with a small scaling coefficient of 1:50. Consequently, three scaled models of steel skeleton structures with variable embedded depths have been constructed with fixed and flexible bases. These models are exposed to three seismic input motions: Northridge (1994), Kobe (1995), and Chi-Chi (1999) at the base of the structure as a fixed base and the bedrock level in the soil structure system as a flexible base. The finite element technique is carried out for scaled and real models. Both the scaled and real numerical models are in good agreement with the obtained experimental observations with reasonable accuracy. It is concluded that the lateral deflections are overestimated by excluding embedded depths of structural elements. In the flexible prototype model, the lateral deflections of the superstructure with embedded depths (3 m, 6 m) decrease compared with no embedded depth, in which the maximum reduction percentages of 7-story with embedded depths 3 m and 6 m at the roof floor level are 21% and 42% compared with no embedded depth, respectively, under Northridge earthquake. Otherwise, ignoring the SSI effects (fixed base case), the lateral displacements are underestimated compared with the flexible base. The maximum amplification percentages at the roof floor level between flexible and fixed bases models with variable embedded depths are 35%, 37%, and 65% under Northridge, Kobe, and Chi-Chi earthquakes, respectively. The amplification and reduction percentages may be high or low, mainly depending on soil condition (fixed, flexible), variable embedded depths, characteristics of seismic motion, travel pass, and source of seismic motion. These items are summarized as the frequency domain of the coupled system compared with the frequency domain of the earthquake motion.

22 December 2023 in Buildings
Verified
Journal Article
Open access
PDF file
WLWenxiao Li
Wenxiao Li
YZYilei Zhang
Yilei Zhang
JMJianxun Ma
Jianxun Ma
MHMOHAMMED EL HOSENY
MOHAMMED EL HOSENY
This paper proposes a scale model test to simulate shield tunnel excavation over long distances. The test simulates the whole process of shield tunneling through the Weihe River on Xi’an Metro Line 1, where the tunneling length and diameter reach 100 m and 6 m, respectively. The dimensions of the test setup were 6.0 m × 1.0 m × 1.0 m, the diameter of the tunnel model was 160 mm, and the geometric similarity ratio was 1:40. Finite element analysis and field measurements were performed to complement the test results. By comparing the finite element simulation and field measurement, the scale model test was validated and verified to be reliable. The results show that the test effectively predicts riverbed deformation caused by shield construction. In addition, it can be applied to soil stability analysis and the impact evaluation of surface deformation in other shield-crossing rivers, complex strata, and superstructure groups, providing auxiliary guidance for shield constructions.

20 August 2026 in Structures
Verified
Journal Article
Closed access
YZYuan Zheng
Yuan Zheng
MHMOHAMMED EL HOSENY
MOHAMMED EL HOSENY
JMJianxun Ma
Jianxun Ma
WJWANG Jianning
WANG Jianning
XYXu Yang
Xu Yang
YYYanchao Yue
Yanchao Yue

26 September 2022 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
MHMOHAMMED EL HOSENY
MOHAMMED EL HOSENY
JMJianxun Ma
Jianxun Ma
DLDong Luo
Dong Luo
YYYanchao Yue
Yanchao Yue
This paper aims to determine the appropriate scaling coefficient rigorously in the dynamic analysis of structures via small shaking table tests to represent the full real case while considering the soil-structure interaction problem. In addition, we investigate the seismic effects of the superstructure with flexible and fixed bases. To achieve this purpose, seven stories of concrete moment-resisting frames supported on silty clay soil were scaled. According to the shaking table specifications, a small-scaled soil-structure model was executed with a scaled factor of 1 : 50. Consequently, the scale steel skeleton model was built to represent the real superstructure. In addition, the laminar soil container for the soil block was constructed to reduce undesirable boundary effects. Three earthquakes have been applied at the superstructure base as a fixed base and at the bottom of the soil block in the soil structure system as a flexible base. The numerical simulations are implemented for scaled and real models. According to obtained results from experimental and numerical investigations, the numerical model achieved good results with experimental observation. In addition, the small scaling factor of 1 : 50 can represent the seismic response of full construction conditions with acceptable precision. It is observed that the flexible base has overestimated in lateral displacement of the real superstructure compared with a fixed base, in which the maximum amplification percentage at the roof floor level reaches up to 98% under seismic load. Otherwise, the shear force distribution along the height and base shear of the superstructure with a flexible base decreases compared with a fixed base. The maximum reduction percentage is 38% under seismic load. Consequently, the safety and cost of the superstructure are affected.