Mahnaz M. Abdi

Dr. Mahnaz M. Abdi

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2012 in Journal of Polymers and the Environment
Verified
Journal Article
Closed access
PDF file
Mehdi JonoobiMehdi Jonoobi
Mehdi Jonoobi
AMAji P. Mathew
Aji P. Mathew
Mahnaz M. AbdiMahnaz M. Abdi
Mahnaz M. Abdi
MMMajid Davoodi Makinejad
Majid Davoodi Makinejad
Kristiina OksmanKristiina Oksman
Kristiina Oksman

10 May 2017 in RSC Advances
Verified
Journal Article
Open access
PDF file
RRRawaida Liyana Razalli
Rawaida Liyana Razalli
Mahnaz M. AbdiMahnaz M. Abdi
Mahnaz M. Abdi
PTParidah M. Tahir
Paridah M. Tahir
AMAmin Moradbak
Amin Moradbak
YSYusran Sulaiman
Yusran Sulaiman
LHLee Yook Heng
Lee Yook Heng
Crystalline nanocellulose was prepared from Semantan bamboo (Gigantochloa scortechinii) via acid hydrolysis and was used to synthesize a nanocomposite of polyaniline/crystalline nanocellulose (PANi/CNC) via in situ oxidative polymerization of aniline in the presence of crystalline nanocellulose. The electrochemical properties of the nanocomposite were studied using a modified PANi/CNC electrode via cyclic voltammetry, and higher current response was observed for the PANi/CNC-modified electrode compared to that for the modified electrode with PANi. The results obtained from EIS displayed lower value of Rct for the PANi/CNC-modified electrode, indicating that the incorporation of CNC into the PANi structure could enhance the electron transfer rate. The characteristic peaks of PANi and CNC were observed in the FTIR spectra of the nanocomposite, indicating the incorporation of CNC inside the nanocomposite structure. Moreover, in the XRD diffractogram, lower crystallinity was observed at the 2 theta values of 22.6 and 16.1 for PANi/CNC compared to that for pure CNC. The FESEM images showed high porosity of the nanostructure with no phase separation, revealing the homogenous polymerization of the monomer on the surface of the crystalline cellulose. Aggregation of PANi particles was observed with the increasing aniline concentration.

24 September 2015 in Sensors
Verified
Journal Article
Open access
PDF file
CEChakavak Esmaeili
Chakavak Esmaeili
Mahnaz M. AbdiMahnaz M. Abdi
Mahnaz M. Abdi
AMAji Mathew
Aji Mathew
Mehdi JonoobiMehdi Jonoobi
Mehdi Jonoobi
Kristiina OksmanKristiina Oksman
Kristiina Oksman
MRMajid Rezayi
Majid Rezayi
Integrating polypyrrole-cellulose nanocrystal-based composites with glucose oxidase (GOx) as a new sensing regime was investigated. Polypyrrole-cellulose nanocrystal (PPy-CNC)-based composite as a novel immobilization membrane with unique physicochemical properties was found to enhance biosensor performance. Field emission scanning electron microscopy (FESEM) images showed that fibers were nanosized and porous, which is appropriate for accommodating enzymes and increasing electron transfer kinetics. The voltammetric results showed that the native structure and biocatalytic activity of GOx immobilized on the PPy-CNC nanocomposite remained and exhibited a high sensitivity (ca. 0.73 μA·mM−1), with a high dynamic response ranging from 1.0 to 20 mM glucose. The modified glucose biosensor exhibits a limit of detection (LOD) of (50 ± 10) µM and also excludes interfering species, such as ascorbic acid, uric acid, and cholesterol, which makes this sensor suitable for glucose determination in real samples. This sensor displays an acceptable reproducibility and stability over time. The current response was maintained over 95% of the initial value after 17 days, and the current difference measurement obtained using different electrodes provided a relative standard deviation (RSD) of 4.47%.

6 December 2018 in ACS Applied Energy Materials
Verified
Journal Article
Closed access
AMAbdolkhaled Mohammadi
Abdolkhaled Mohammadi
SMSeyyed Ebrahim Moosavifard
Seyyed Ebrahim Moosavifard
ATAmin Goljanian Tabrizi
Amin Goljanian Tabrizi
Mahnaz M. AbdiMahnaz M. Abdi
Mahnaz M. Abdi
GKGholamreza Karimi
Gholamreza Karimi

1 April 2019 in International Journal of Biological Macromolecules
Verified
Journal Article
Closed access
Mahnaz M. AbdiMahnaz M. Abdi
Mahnaz M. Abdi
RRRawaida Liyana Razalli
Rawaida Liyana Razalli
PTParidah Md Tahir
Paridah Md Tahir
NCNaz Chaibakhsh
Naz Chaibakhsh
MHMaryam Hassani
Maryam Hassani
MMMahdi Mir
Mahdi Mir

31 May 2017 in Nanomaterials
Verified
Journal Article
Open access
PDF file
AAALI AL-MOKARAM
ALI AL-MOKARAM
RYRosiyah Yahya
Rosiyah Yahya
Mahnaz M. AbdiMahnaz M. Abdi
Mahnaz M. Abdi
HMH. N.M. Ekramul Mahmud
H. N.M. Ekramul Mahmud
The performance of a modified electrode of nanocomposite films consisting of polypyrrole–chitosan–titanium dioxide (Ppy-CS-TiO2) has been explored for the developing a non-enzymatic glucose biosensors. The synergy effect of TiO2 nanoparticles (NPs) and conducting polymer on the current responses of the electrode resulted in greater sensitivity. The incorporation of TiO2 NPs in the nanocomposite films was confirmed by X-ray photoelectron spectroscopy (XPS) spectra. FE-SEM and HR-TEM provided more evidence for the presence of TiO2 in the Ppy-CS structure. Glucose biosensing properties were determined by amperommetry and cyclic voltammetry (CV). The interfacial properties of nanocomposite electrodes were studied by electrochemical impedance spectroscopy (EIS). The developed biosensors showed good sensitivity over a linear range of 1–14 mM with a detection limit of 614 μM for glucose. The modified electrode with Ppy-CS nanocomposite also exhibited good selectivity and long-term stability with no interference effect. The Ppy-CS-TiO2 nanocomposites films presented high electron transfer kinetics. This work shows the role of nanomaterials in electrochemical biosensors and describes the process of their homogeneous distribution in composite films by a one-step electrochemical process, where all components are taken in a single solution in the electrochemical cell.