Marcos Esteban Sánchez

Mr. Marcos Esteban Sánchez

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2023 in IEEE Access
Verified
Journal Article
Open access
RJRUBEN PASCUAL JIMENEZ
RUBEN PASCUAL JIMENEZ
Carlos A. PlateroCarlos A. Platero
Carlos A. Platero
MSMarcos Esteban Sánchez
Marcos Esteban Sánchez
EBEduardo Rivero Barneto
Eduardo Rivero Barneto
The massive integration of renewable energies into the grid towards the de-carbonisation of the power system has a major impact on the stability of the grid. This has led the European Union to establish guidelines on how renewable plants should be connected to the grid, in order to continue to guarantee their operation and stability. These requirements are contained in the European Grid Code. In this code, there are requirements concerning voltage control, reactive power capacity, fault-ride-through and short-circuit current contribution capabilities of renewable power plants. These plants, in particular those powered by photovoltaic inverters, have issues of reactive power capacity, so in order to be able to connect to the grid, they usually require an oversized of the inverters or the installation of reactive power compensation elements, such as capacitor banks, static VAR compensator or synchronous condensers. Moreover, the fault-ride-through and short-circuit current contribution are difficult to fulfil as they are inverter-based generators have a low capacity to supply short-circuit current and, in some cases, they disconnect from the grid. These facts have produced large power losses and protection malfunctions in power system with high photovoltaic power penetration. This paper studies the compliance of the European Grid Code of a 500 MW photovoltaic power plant with and without a synchronous condenser. The results show that not only the use of the synchronous condenser helps for reactive power regulation but also for fault-ride-through and short-circuit current contribution.

6 May 2025 in Machines
Verified
Journal Article
Open access
PDF file
RJRUBEN PASCUAL JIMENEZ
RUBEN PASCUAL JIMENEZ
MSMarcos Esteban Sánchez
Marcos Esteban Sánchez
JGJose Manuel Guerrero
Jose Manuel Guerrero
Carlos A. PlateroCarlos A. Platero
Carlos A. Platero
This work presents the development of an adaptive thermal protection system for synchronous machines (SMs), taking into consideration the final cooling temperature and the operation point of the machine. This system aims to improve current thermal protections, which consist of a fixed alarm and trip thresholds regardless of the generator’s operating point or ambient temperature. A recurrent neural network (RNN)-based approach has been employed to predict SM temperatures during operation. Multiple tests have been conducted on a specially designed test bench. Inside the windings and iron core of the 5.5 kVA generator, multiple Pt100 sensors have been installed to train the neural network with real temperature values, enabling accurate predictions. The selected RNN model is Long Short-Term Memory (LSTM). Its inputs include electrical variables and the inlet and outlet air temperatures of the SM’s cooling system. The results show that the model accurately defines warning and trip thresholds, significantly improving thermal protection, as these thresholds are no longer fixed values. Additionally, the study suggests validating the model under cooling system failures and exploring its application in water-cooled systems. This research is supported by a patent on real-time thermal diagnostics for synchronous machines, highlighting its potential contribution to predictive maintenance and the monitoring of power generation systems.