María José Inestrosa Izurieta

Dr. María José Inestrosa Izurieta

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2014 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
LSLeopoldo Soto
Leopoldo Soto
CPCristian Pavez
Cristian Pavez
JMJosé Moreno
José Moreno
MIMaría José Inestrosa Izurieta
María José Inestrosa Izurieta
FVFelipe Veloso
Felipe Veloso
LDLuis F. Delgado-Aparicio
Luis F. Delgado-Aparicio
The characterization of plasma bursts produced after the pinch phase in a plasma focus of hundreds of joules, using pulsed optical refractive techniques, is presented. A pulsed Nd-YAG laser at 532 nm and 8 ns FWHM pulse duration was used to obtain Schlieren images at different times of the plasma dynamics. The energy, interaction time with a target, and power flux of the plasma burst were assessed, providing useful information for the application of plasma focus devices for studying the effects of fusion-relevant pulses on material targets. In particular, it was found that damage factors on targets of the order of 104 (W/cm2)s1/2 can be obtained with a small plasma focus operating at hundred joules.

5 August 2015 in Nuclear Fusion
Verified
Journal Article
Closed access
MIMaría José Inestrosa Izurieta
María José Inestrosa Izurieta
ERE. Ramos-Moore
E. Ramos-Moore
LSL. Soto
L. Soto

1 December 2021 in Desalination
Verified
Journal Article
Closed access
AYAmanda Yáñez-Fernández
Amanda Yáñez-Fernández
MIMaría José Inestrosa Izurieta
María José Inestrosa Izurieta
JUJulio I. Urzúa
Julio I. Urzúa

18 October 2023 in Heliyon
Verified
Journal Article
Open access
MIMaría José Inestrosa Izurieta
María José Inestrosa Izurieta
DVDiego Pablo Vilches
Diego Pablo Vilches
JUJulio I. Urzúa
Julio I. Urzúa
For this work, iron oxide nanoparticles are synthesized by the co-precipitation method with stoichiometric amounts of Fe2+ and Fe3+ salts in a 1:2 ratio in distilled water and the pH is raised by adding an aqueous ammonia solution by controlled dripping. Nanoparticles precipitating after the reaction time are magnetically filtered and stored in ethanol for further analysis. Superparamagnetic Fe3O4 nanoparticles with a slight deviation from the stoichiometry are obtained, with sizes between 7.4 and 12.8 nm and saturation magnetization between 40 and 78 emu/gr. At pH 6, rod-shaped nanoparticles are obtained in addition to spherical ones. With a statistical design, it is shown how the morphological, structural and magnetic properties of the resulting nanoparticles can be manipulated by the synthesis parameters, offering many possibilities to tailor the materials to a wide range of applications.

4 February 2022 in Journal of Molecular Liquids
Verified
Journal Article
Closed access
JCJenifer Cavieres
Jenifer Cavieres
MIMaría José Inestrosa Izurieta
María José Inestrosa Izurieta
Diego Andrés Andrés Vasco CalleDiego Andrés Andrés Vasco Calle
Diego Andrés Andrés Vasco Calle
JUJulio I. Urzúa
Julio I. Urzúa

1 May 2016 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
JJJ. Jain
J. Jain
JMJ. Moreno
J. Moreno
GAG. Avaria
G. Avaria
CPC. Pavez
C. Pavez
BBB. Bora
B. Bora
LSLeopoldo Soto
Leopoldo Soto
With the purpose to study the effects of pulsed x-rays radiation on cancer cells, the total doses of x-ray pulses and the temporal duration of the pulse has been characterized in a hundred joules plasma focus device (PF-400J, 130 kA achieved in 300ns, 30 kV, 880 nF, 38 nH). TLD dosimeters were located outside of the discharge chamber, at 96 mm from the anode top. In addition, two photomultipliers with plastic scintillator were located in axial and radial directions. From the statistical analysis of the TLD and photomultiplier signals, was possible to estimate that a single shot has a total dose of the order of 30±15 µSv with a duration of the order of 12±3.6 ns at FWHM. Preliminary experiments using MCF7, a breast cancer cell line, were performed. Cells were irradiated at 96 mm from the anode top with 300 cumulative x-ray shots and cell proliferation was evaluated at 24, 48 and 72 hours later.