In this paper the design of a Fault Detection and Isolation (FDI) system for a flyback converter, based on a fuzzy unknown-input observer, is presented. The proposed FDI system aims to detect the saturation in the inductor core as a fault, considering the current increment can cause an avalanche effect provoking a failure in the system. A Takagi-Sugeno model of the Flyback converter is used. The observers convergence and the stability of the fault diagnosis system are guaranteed by the Lyapunovs theory and the estimation error used to determine the necessary LMIs. A comparison of different FDI methods applied in fuzzy systems is performed in order to select the most robust system, capable of estimate the current in the system even in the presence of external disturbances. The system validation is performed in both, simulation and online implementation, using experimental data.
In this paper, as an introduction, the nonlinear model of a distillation column is presented in order to understand the fundamental paper that the column heating actuator has in the distillation process dynamics as well as in the quality and safety of the process. In order to facilitate the implementation control strategies to maintain the heating power regulated in the distillation process, it is necessary to represent adequately the heating power actuator behavior; therefore, three different models (switching, nonlinear and fuzzy Takagi–Sugeno) of a DC-DC Buck-Boost power converter, selected to regulate the electric power regarding the heating power, are presented and compared. Considering that the online measurements of the two main variables of the converter, the inductor current and the capacitor voltage, are not always available, two different fuzzy observers (with and without sliding modes) are developed to allow monitoring the physical variables in the converter. The observers response is compared to determine which has a better performance. The role of the observer in estimating the state variables with the purpose of using them in the sensors fault diagnosis, using the analytical redundancy concept, likewise, from the estimation of these variables other non-measurable can be determined; for example, the caloric power. The stability analysis and observers gains are obtained by linear matrix inequalities (LMIs). The observers are validated by MATLAB simulations to verify the observers convergence and analyze their response under system disturbances.
This paper presents the design of a fault detection system (FDD) based on principal component analysis (PCA) to detect faults in the transient state of distillation processes. The FDD system detects faults due to changes in calorific power and pressure leaks that can occur during the heating of the mixture to be distilled (transient), mainly affecting the quality of the distilled product and the safety of the process and operators. The proposed FDD system is based on PCA with a T2 Hotelling statistical approach, considering data from a real distillation pilot plant process. The FDD system is evaluated with two fault scenarios, performing power changes and pressure leaks in the pilot plant reboiler during the transient state. Finally, the results of the FDD system are analyzed using Accuracy, Precision, Recall, and Specificity metrics to validate its performance.
In this chapter, the analysis and design of a fuzzy observer based on a Takagi-Sugeno model of a batch distillation column are presented. The observer estimates the molar compositions and temperatures of the light component in the distillation column considering a binary mixture. This estimation aims to allow monitoring the physical variables in the process to improve the quality of the distillated product as well as to detect failures that could affect the system performance. The Takagi-Sugeno fuzzy model is based on eight linear subsystems determined by three premise variables: the opening percentage of the reflux valve and the liquid molar composition of the light element of the binary mixture in the boiler and in the condenser. The stability analysis and the observer gains are obtained by linear matrix inequalities (LMIs). The observer is validated by MATLAB® simulations using real data obtained from a distillation column to verify the observer’s convergence and analyze its response under system disturbances.
Heat exchange systems are widely used in industry to transfer thermal energy from one body to another with a definite purpose, as in the distillation process. However, it is essential to have an adequate control system to ensure the proper process operation. This paper presents the modelling, simulation and implementation of a controlled actuator for a distillation column boiler. The proposed actuator is an electrical scheme to control the electric power of the boiler heating resistor in order to control the heat output used in the distillation column. The actuator model consists of an AC-DC converter, a DC-DC Buck converter and a PI voltage controller. The model is simulated in Matlab and validated in a real prototype.
Infrared thermography (IRT) is a widely used non-contact technique for quantifying thermal performance in industrial heating systems. This study employs IRT to analyze and compare the thermal behavior and electrical power efficiency of a heating resistor within a distillation column boiler under alternating current (AC) and direct current (DC) power supply. Experiments were conducted using a distillation pilot plant, which included a 130 W heating resistor powered by an AC (60 Hz) source and an equivalent DC source considering different voltage-current configurations. Thermal dynamics were captured using a calibrated mid-wave IR camera (7.5 to 13 µm spectral range), in parallel with electrical power measurements from a data-acquisition card embedded system. The proposed methodology establishes an IRT protocol for quantifying thermal responses via IRT images, allowing for mapping 2D temperature heterogeneity through emissivity-corrected thermograms. Power efficiency analyses showed DC reduced Joule losses while AC exhibited superior thermal stability during prolonged operation. This IRT-integrated approach provides actionable insights for optimizing distillation energy systems and aligns with industrial electrification initiatives. The protocol is scalable for infrared-based monitoring of thermo-electric processes in chemical, pharmaceutical, and renewable energy applications.