Juan Anzurez Marin

Juan Anzurez Marin

Auto-generated profile, based on publicly available information

Juan Anzurez Marin

Facultad de Ingeniería Eléctrica, Universidad Michoacana de San Nicolás de Hidalgo, Morelia, Michoacán, México

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015 in ISA Transactions
Verified
Journal Article
Closed access
HBHazael Ballesteros-Moncada
Hazael Ballesteros-Moncada
Enrique Herrera-LópezEnrique Herrera-López
Enrique Herrera-López
JAJuan Anzurez-Marín
Juan Anzurez-Marín

1 February 2024 in IEEE Access
Verified
Journal Article
Open access
JRJorge Iván Bermúdez Rodríguez
Jorge Iván Bermúdez Rodríguez
HLHéctor Ricardo Hernández-De León
Héctor Ricardo Hernández-De León
JMJuan Anzurez Marín
Juan Anzurez Marín
AMAlejandro Medina-Santiago
Alejandro Medina-Santiago
EEElías Neftalí Escobar-Gómez
Elías Neftalí Escobar-Gómez
Julio Alberto Guzman RabasaJulio Alberto Guzman Rabasa
Julio Alberto Guzman Rabasa
This paper presents a fault diagnosis (FDD) approach based on a Takagi-Sugeno Unknown Input Observer (TS-UIO) that allows for estimation of the states of an active pitch system for a studied wind turbine even in the presence of unknown interference factors. A scheme for FDD is proposed based on the residuals evaluation between the non-linear model of the active pitch system and the Takagi-Sugeno unknown input observer proposed for the detection and isolation of faults in sensors with measurable premise variables. The proposed TS-UIO State Observer is resilient to disturbances and measurement noise due to its unique feature of decoupling unknown inputs, interruptions or undefined factors that affect the behavior of the system under study. This study investigates the effect of load-induced stress on the mechanical blades of a wind turbine, caused by the wind force considered as an unknown disturbance or input to the system given its dependence on weather conditions. The proposed FDD algorithm includes Linear Matrix Inequalities (LMI) ensuring the estimation error dynamics approximates to zero. Successful implementation tests are demonstrated in an active pitch system with reference parameters based on a wind turbine model. The review outlines traditional FDD approaches, including those based on nonlinear models, as well as relatively new methods based on linear sector conditions. Special attention is given to Takagi-Sugeno (TS) methods.

7 July 2020 in IEEE Transactions on Fuzzy Systems
Verified
Journal Article
Closed access
JSJuan Jesus Silva-Romero
Juan Jesus Silva-Romero
ATAdriana del Carmen Téllez-Anguiano
Adriana del Carmen Téllez-Anguiano
JAJuan Anzurez-Marin
Juan Anzurez-Marin
RJRicardo Fabricio Escobar Jiménez
Ricardo Fabricio Escobar Jiménez
MCMario Cervantes
Mario Cervantes
In this paper the design of a Fault Detection and Isolation (FDI) system for a flyback converter, based on a fuzzy unknown-input observer, is presented. The proposed FDI system aims to detect the saturation in the inductor core as a fault, considering the current increment can cause an avalanche effect provoking a failure in the system. A Takagi-Sugeno model of the Flyback converter is used. The observers convergence and the stability of the fault diagnosis system are guaranteed by the Lyapunovs theory and the estimation error used to determine the necessary LMIs. A comparison of different FDI methods applied in fuzzy systems is performed in order to select the most robust system, capable of estimate the current in the system even in the presence of external disturbances. The system validation is performed in both, simulation and online implementation, using experimental data.

Verified
Journal Article
Open access
PDF file
MCMario Cervantes
Mario Cervantes
ATAdriana del Carmen Téllez-Anguiano
Adriana del Carmen Téllez-Anguiano
JAJuan Anzurez-Marín
Juan Anzurez-Marín
EEElisa Espinosa-Juárez
Elisa Espinosa-Juárez
In this paper, as an introduction, the nonlinear model of a distillation column is presented in order to understand the fundamental paper that the column heating actuator has in the distillation process dynamics as well as in the quality and safety of the process. In order to facilitate the implementation control strategies to maintain the heating power regulated in the distillation process, it is necessary to represent adequately the heating power actuator behavior; therefore, three different models (switching, nonlinear and fuzzy Takagi–Sugeno) of a DC-DC Buck-Boost power converter, selected to regulate the electric power regarding the heating power, are presented and compared. Considering that the online measurements of the two main variables of the converter, the inductor current and the capacitor voltage, are not always available, two different fuzzy observers (with and without sliding modes) are developed to allow monitoring the physical variables in the converter. The observers response is compared to determine which has a better performance. The role of the observer in estimating the state variables with the purpose of using them in the sensors fault diagnosis, using the analytical redundancy concept, likewise, from the estimation of these variables other non-measurable can be determined; for example, the caloric power. The stability analysis and observers gains are obtained by linear matrix inequalities (LMIs). The observers are validated by MATLAB® simulations to verify the observers convergence and analyze their response under system disturbances.

1 January 2023
Verified
Book
Closed access
Efrain AlcortaEfrain Alcorta
Efrain Alcorta
FLFacultad de Ingeniería Mecánica Y Eléctrica Universidad Autónoma de Nuevo León
Facultad de Ingeniería Mecánica Y Eléctrica Universidad Autónoma de Nuevo León
JMJuan Anzurez Marin
Juan Anzurez Marin
UHUniversidad Michoacana de San Nicolás Hidalgo
Universidad Michoacana de San Nicolás Hidalgo
RCRolando Carrera-Méndez
Rolando Carrera-Méndez
UTUnidad Académica Rohde-Reynosa Universidad Autónoma de Tamaulipas
Unidad Académica Rohde-Reynosa Universidad Autónoma de Tamaulipas
The problem of automatic fault diagnosis and tolerant control for dynamic systems has become essential research topic during the last years as part of the industry’s monitoring and supervision of complex systems. This fact has motivated diverse research groups who are developing fault diagnosis technologies in Mexican academic institutions. Thereby, the fault diagnosis community considered it relevant to share our experience by showing the benefits of the novel diagnostic techniques implemented by software with some applications tested in our country. Thus, this monograph, written by several experts, has been prepared by selecting the main topics discussed during the seminar on Fault Diagnosis and Tolerant Control organized face-to-face and virtual by the authors over the last four years. The Topics features include: (a) The design of a robust computer numerical control CNC of new generation; (b) The faults isolation problem in sensors and actuators of a helicopter prototype; (c) Failure diagnosis in the boiler system of a distillation column; (d) The remaining functional live analysis of an aerospace propulsion system; and (e) Three issues associated with leaks in pipelines. One relates to a water distribution network; the second shows an algorithm to isolate sequential leaks in the main conduit, and the last links with the estimation of the head loss of the line in real-time.

1 November 2016
Verified
Conference Paper
Closed access
MCMario Cervantes
Mario Cervantes
JAJuan Anzurez-Marin
Juan Anzurez-Marin
ATAdriana del Carmen Téllez-Anguiano
Adriana del Carmen Téllez-Anguiano
MGMaria Del Carmen Garcia-Ramirez
Maria Del Carmen Garcia-Ramirez
JCJavier Correa-Gomez
Javier Correa-Gomez
Heat exchange systems are widely used in industry to transfer thermal energy from one body to another with a definite purpose, as in the distillation process. However, it is essential to have an adequate control system to ensure the proper process operation. This paper presents the modelling, simulation and implementation of a controlled actuator for a distillation column boiler. The proposed actuator is an electrical scheme to control the electric power of the boiler heating resistor in order to control the heat output used in the distillation column. The actuator model consists of an AC-DC converter, a DC-DC Buck converter and a PI voltage controller. The model is simulated in Matlab and validated in a real prototype.