Percutaneous Nephrolithotomy is the standard surgical procedure used to remove large kidney stones. PCNL procedures have a steep learning curve; a physician needs to complete between 36 and 60 procedures, to achieve clinical proficiency. Marion Surgical K181 is a virtual reality surgical simulator, which emulates the PCNL procedures without compromising the well-being of patients. The simulator uses a VR headset to place a user in a realistic and immersive operating theater, and haptic force-feedback robots to render physical interactions between surgical tools and the virtual patient. The simulator has two modules for two different aspects of PCNL kidney stone removal procedure: kidney access module where the user must insert a needle into the kidney of the patient, and a kidney stone removal module where the user removes the individual stones from the organ. In this paper, we present user trials to validate the face and construct validity of the simulator. The results, based on the data gathered from 4 groups of users independently, indicate that Marion's surgical simulator is a useful tool for teaching and practicing PCNL procedures. The kidney stone removal module of the simulator has proven construct validity by identifying the skill level of different users based on their tool path. We plan to continue evaluating the simulator with a larger sample of users to reinforce our findings.
The sustained increase in new cases of COVID-19 across the world and potential for subsequent outbreaks call for new tools to assist health professionals with early diagnosis and patient monitoring. Growing evidence around the world is showing that lung ultrasound examination can detect manifestations of COVID-19 infection. Ultrasound imaging has several characteristics that make it ideally suited for routine use: small hand-held systems can be contained inside a protective sheath, making it easier to disinfect than X-ray or computed tomography equipment; lung ultrasound allows triage of patients in long term care homes, tents or other areas outside of the hospital where other imaging modalities are not available; and it can determine lung involvement during the early phases of the disease and monitor affected patients at bedside on a daily basis. However, some challenges still remain with routine use of lung ultrasound. Namely, current examination practices and image interpretation are quite challenging, especially for unspecialized personnel. This paper reviews how lung ultrasound (LUS) imaging can be used for COVID-19 diagnosis and explores different image processing methods that have the potential to detect manifestations of COVID-19 in LUS images. Then, the paper reviews how general lung ultrasound examinations are performed before addressing how COVID-19 manifests itself in the images. This will provide the basis to study contemporary methods for both segmentation and classification of lung ultrasound images. The paper concludes with a discussion regarding practical considerations of lung ultrasound image processing use and draws parallels between different methods to allow researchers to decide which particular method may be best considering their needs. With the deficit of trained sonographers who are working to diagnose the thousands of people afflicted by COVID-19, a partially or totally automated lung ultrasound detection and diagnosis tool would be a major asset to fight the pandemic at the front lines.
Percutaneous Nephrolithotomy (PCNL) is a procedure used to treat kidney stones. In PCNL, a needle punctures the kidney through an incision in a patient’s back and thin tools are threaded through the incision to gain access to kidney stones for removal. Despite being one of the main endoscopic procedures for managing kidney stones, PCNL remains a difficult procedure to learn with a long and steep learning curve. Virtual reality simulation with haptic feedback is emerging as a new method for PCNL training. It offers benefits for both novices and experienced surgeons. In the first case, novices can practice and gain kidney access in a variety of simulation scenarios without offering any risk to patients. In the second case, surgeons can use the simulator for preoperative surgical rehearsal. This paper proposes the first preliminary study of PCNL surgical rehearsal using the Marion Surgical PCNL simulator. Preoperative CT scans of a patient scheduled to undergo PCNL are used in the simulator to create a 3D model of the renal system. An experienced surgeon then planned and practiced the procedure in the simulator before performing the surgery in the operating room. This is the first study involving survival rehearsal using a combination of VR and haptic feedback in PCNL before surgery. Preliminary results confirm that surgical rehearsal using a combination of virtual reality and haptic feedback strongly affects decision making during the procedure.
Percutaneous nephrolithotomy (PCNL) is a minimally invasive procedure to remove large renal calculi through a small incision in the patient’s back. Ultrasound (US) imaging is commonly used to guide the needle to the kidney during this procedure. However, it requires an advanced level of dexterity to coordinate the US probe and the needle to keep the needle visible in the images at all times. Failure to maintain needle-probe alignment can result in inadvertent injury, bleeding, and other complications. The use of robotic assistance can alleviate the surgeon’s cognitive workload by enabling autonomous positioning of the US probe and accurate needle tracking. This paper presents a new US-guided visual servoing (VS) algorithm for needle tracking using longitudinal US images of a needle subjected to out-of-plane motion. The ultrasound probe can move in 4 degrees-of-freedom (DOF), that is, two translations and one rotation in the imaging plane, and one rotation out of the imaging plane. Unlike previously reported VS algorithms, 4-DOF tracking is achieved using only 2D-US images and without any additional position sensor or prior knowledge of the needle trajectory. The algorithm is validated extensively in three different experimental scenarios using a water tank, a tissue phantom, and ex-vivo porcine tissue. Results obtained from several trials confirm the algorithm’s ability to track the needle and maintain needle-probe alignment with an average error of 1.5 mm, despite an out-of-plane average needle deflection of 7 mm along a 60 mm insertion depth.