José Manuel Mendes

Prof. Dr. José Manuel Mendes

UNIPRO – Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, Gandra, Portugal
+1
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
João Fontes PereiraJoão Fontes Pereira
João Fontes Pereira
Rosana CostaRosana Costa
Rosana Costa
MVMiguel Nunes Vasques
Miguel Nunes Vasques
FSFilomena Salazar
Filomena Salazar
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
Marco Infante da CamaraMarco Infante da Camara
Marco Infante da Camara
Osseodensification is an innovative method of preparing the implant osteotomy using drills that promote bone self-compaction. The main objective of this technique is to promote peri-implant bone densification and compaction of autologous bone and to increase the primary stability of the implant due to the viscoelastic characteristics of the alveolar bone using Densah® burs in a counterclockwise direction at a speed of 800 to 1500 rpm. The objective of this review is the analysis of the scientific literature regarding the applicability of the osseodensification technique in oral implantology. The Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines were used and registered at PROSPERO. The search strategy included electronic databases from 2016 to 2023 and was performed by two independent reviewers. The results demonstrate the advantage of the osseodensification technique in relation to conventional drilling, allowing an increase in the bone density and primary stability of the implant, bone density, and bone–implant contact. The osseodensification technique can be applied in different clinical situations: sub-antral bone grafts, narrow alveolar bone crests, low-density bone areas, and immediate implant placement in post-extraction sockets.

14 April 2023 in Oral Radiology
Verified
Journal Article
Open access
PDF file
JCJosé Adriano Costa
José Adriano Costa
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
FSFilomena Salazar
Filomena Salazar
JPJ. J. Pacheco
J. J. Pacheco
Paulo RompantePaulo Rompante
Paulo Rompante
Marco Infante da CamaraMarco Infante da Camara
Marco Infante da Camara
The objective of this work was to perform an integrative review of the inspection of peri-implant bone defects using cone beam computed tomography (CBCT). An electronic search was performed in the PubMed database using the following scientific terms: CBCT or Cone Beam computed tomography; dental implant; peri-implant; bone loss; defects. The survey identified 267 studies, of which 18 were considered relevant to this study. These studies provided important data taking into account the accuracy of cone beam computed tomography in the detection and measurement of peri-implant bone defects such as fenestrations, dehiscence and intraosseous circumferential defects. The effectiveness of CBCT in aiding in geometric bone calculations and in the diagnosis of peri-implant defects was influenced by factors such as artefacts, defect size, bone wall thickness, implant material, adjustment of acquisition parameters and observer experience. A not insignificant number of studies compared intraoral radiography to CBCT in the detection of peri-implant bone loss. CBCT was clearly superior to intraoral radiography in the detection of all peri-implant bone defects, except for defects located in the interproximal zone. In general, studies have shown that peri-implant bone measurements adjacent to the implant surface can be correctly determined, as well as the diagnosis of peri-implant bone defects with an average discrepancy of less than 1 mm from the actual measurement of the defect.

1 January 2019 in Patient Preference and Adherence
Verified
Journal Article
Open access
PDF file
CBCristina Bucchi
Cristina Bucchi
MFMassimo del Fabbro
Massimo del Fabbro
AAAlain Arias
Alain Arias
RFRamón Fuentes
Ramón Fuentes
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
MCMaria Cristina Manzanares Céspedes
Maria Cristina Manzanares Céspedes
Purpose: Bone graft materials can be obtained from the patient’s own body (autologous graft), animals (xenograft), human cadavers (allograft) and synthetic materials (alloplastic bone graft). Patients may have ethical, religious or medical concerns about the origin of bone grafts, which could lead them to reject the use of certain types of bone graft in their treatments. The aim of this multicenter study, which surveyed patients from five university clinics in Portugal, France, Italy, Spain and Chile, was to analyze patients’ opinions regarding the source of bone grafts. Patients and methods: A survey composed of ten questions was translated into local languages and validated. Patients were asked about the degree of acceptance/rejection of each graft and the reasons for rejection. A chi-squared test was used to analyze statistically significant differences. Results: Three hundred thirty patients were surveyed. The grafts that elicited the highest percentage of refusal were allograft (40.4%), autologous bone graft from an extraoral donor site (34%) and xenograft (32.7%). The grafts with the lowest rate of refusal were alloplastic (6.3%) and autologous bone grafts from an intraoral donor site (24.5%). The main reason for autologous bone rejection was the fear of pain and discomfort, for xenograft it was the fear of disease transmission and the rejection of use of animals for human benefit, and for allograft it was ethical/moral motivations and the fear of disease transmission. Religious affiliation influenced patient’s preferences. Conclusion: The origin of bone grafts is still conflictive for a high percentage of patients.

24 August 2021 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
ABAnne Le Guen Bentata
Anne Le Guen Bentata
JSJuliana de Sá
Juliana de Sá
António Sérgio SilvaAntónio Sérgio Silva
António Sérgio Silva
This study aimed to review clinical publications involving anterior-region resin-bonded fixed partial dentures to evaluate their survival rates vis-à-vis their materials and design. An electronic search was conducted using PubMed/MEDLINE to identify articles that reported on the longevity of anterior resin-bonded fixed dental prostheses published between 2000 and 2020. Only primary clinical studies that involved a follow-up after at least 3 years were included in this review. A statistical analysis was performed to evaluate resin-bonded fixed dental prostheses’ survival rates in relation to their materials and design. This review ultimately included 23 clinical publications, comprising prospective studies, retrospective studies, and randomized controlled trials. Its statistical analysis estimated the studied prostheses’ 5-year survival rate at 86.2% for metal-framed prostheses, 87.9% for zirconia prostheses, 93.3% for alumina prostheses, 100% for glass or ceramic prostheses, and 81.7% for fiber-reinforced composite restorations. Failure rates did not significantly differ between the different material groups or between the single- and double-retainer groups. Resin-bonded fixed dental prostheses present excellent 5-year clinical longevity in the anterior sector and a favorable benefit/risk/cost ratio. Currently, no consensus has been established on an ideal material for these restorations. Cantilever design tends to limit constraints on the prostheses’ retainers and, thus, increases their survival time. All-ceramic cantilever fixed partial dentures can be considered as a definitive therapy, given their high success and survival rates. They are an optimal solution for adolescents or young adults facing potentially continuous growth.

21 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
Lígia Lopes-RochaLígia Lopes-Rocha
Lígia Lopes-Rocha
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
JGJoana Garcez
Joana Garcez
ASAna Góis Sá
Ana Góis Sá
Teresa PinhoTeresa Pinho
Teresa Pinho
OTOrlanda Araújo Lamas Correia Torres
Orlanda Araújo Lamas Correia Torres
The purpose of this study was to evaluate the color stability of aesthetic restorative resin-matrix materials after their immersion in different dietary and therapeutic solutions. Thirty disc-shaped specimens (10 × 2 mm) were prepared from three different types of resin-matrix composites used in dentistry (BE, FS, AF). The color coordinates (L*a*b*, ΔL*, Δa*, Δa*, Δb* and ΔE*) were measured using a VITA Easyshade 3D-Master (VITA Zahnfabrik, Bad Säckingen, Germany) before and after the immersion of the specimens in coffee, red wine, Coca-Cola®, Eludril Care®, and distilled water solutions for 40 h. The color change (ΔE*) was calculated and analyzed by the Kolmogorov -Smirnov test and the Kruskal -Wallis multiple-comparison test. All the restorative materials showed significant color (ΔE*) changes after their exposure to red wine, followed by coffee and Coca-Cola®; however, one nanohybrid resin-matrix composite showed a high color stability in such colored test solutions. The chemical composition and content of the organic matrix played a key role in the color stability of the resin-matrix composites. Clinicians should advise their patients about the chemical interaction between dietary substances and different resin-matrix composites.

11 April 2021 in Polymers
Verified
Journal Article
Open access
PDF file
António Sérgio SilvaAntónio Sérgio Silva
António Sérgio Silva
ACAurora Carvalho
Aurora Carvalho
Pedro BarreirosPedro Barreiros
Pedro Barreiros
JSJuliana de Sá
Juliana de Sá
Carlos ArosoCarlos Aroso
Carlos Aroso
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.