Alexandra Virginia Bounegru

Ms. Alexandra Virginia Bounegru

"Dunarea de Jos" University of Galati, Galaţi, Romania
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2020 in Catalysts
Verified
Journal Article
Open access
PDF file
Alexandra Virginia BounegruAlexandra Virginia Bounegru
Alexandra Virginia Bounegru
Constantin ApetreiConstantin Apetrei
Constantin Apetrei
This paper aims to revise research on carbonaceous nanomaterials used in developing sensors. In general, nanomaterials are known to be useful in developing high-performance sensors due to their unique physical and chemical properties. Thus, descriptions were made for various structural features, properties, and manner of functionalization of carbon-based nanomaterials used in electrochemical sensors. Of the commonly used technologies in manufacturing electrochemical sensors, the screen-printing technique was described, highlighting the advantages of this type of device. In addition, an analysis was performed in point of the various applications of carbon-based nanomaterial sensors to detect analytes of interest in different sample types.

25 August 2023 in Polymers
Verified
Journal Article
Open access
PDF file
Alexandra Virginia BounegruAlexandra Virginia Bounegru
Alexandra Virginia Bounegru
BIBounegru Iulian
Bounegru Iulian
Chitosan (CTS), a biocompatible and multifunctional material derived from chitin, has caught researchers’ attention in electrochemical detection due to its unique properties. This review paper provides a comprehensive overview of the recent progress and applications of CTS-based electrochemical sensors in the analysis of pharmaceutical products and other types of samples, with a particular focus on the detection of medicinal substances. The review covers studies and developments from 2003 to 2023, highlighting the remarkable properties of CTS, such as biocompatibility, chemical versatility, and large surface area, that make it an excellent candidate for sensor modification. Combining CTS with various nanomaterials significantly enhances the detection capabilities of electrochemical sensors. Various types of CTS-based sensors are analyzed, including those utilizing carbon nanomaterials, metallic nanoparticles, conducting polymers, and molecularly imprinted CTS. These sensors exhibit excellent sensitivity, selectivity, and stability, enabling the precise and reliable detection of medications. The manufacturing strategies used for the preparation of CTS-based sensors are described, the underlying detection mechanisms are elucidated, and the integration of CTS sensors with transducer systems is highlighted. The prospects of CTS-based electrochemical sensors are promising, with opportunities for miniaturization, simultaneous detection, and real-time monitoring applications.

11 February 2025 in Chemosensors
Verified
Journal Article
Open access
PDF file
Alexandra Virginia BounegruAlexandra Virginia Bounegru
Alexandra Virginia Bounegru
IAIacob Ancuta
Iacob Ancuta
CICatalina Iticescu
Catalina Iticescu
LGLucian Georgescu
Lucian Georgescu
This review highlights recent advances in the development of electrochemical sensors and biosensors for detecting pharmaceutical contaminants in water samples, including surface water, wastewater, and bottled water. The electrode modification materials—such as nanomaterials, conductive polymers, and eco-friendly nanocomposites—have shown notable improvements in sensor sensitivity and selectivity, enabling the detection of various pharmaceutical compounds, including diclofenac, ibuprofen, antibiotics, and hormones. Future research directions suggest the use of eco-friendly nanocomposites, the development of multiplexed platforms for simultaneous contaminant detection, and the integration of sensors into portable devices for in situ monitoring. Additionally, integrating biosensors with specific biomolecules and IoT technology can expand their applicability, enabling continuous and efficient water quality monitoring, thus supporting public health and environmental protection.

17 February 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Alexandra Virginia BounegruAlexandra Virginia Bounegru
Alexandra Virginia Bounegru
Constantin ApetreiConstantin Apetrei
Constantin Apetrei
The development of enzyme biosensors has successfully overcome various challenges such as enzyme instability, loss of enzyme activity or long response time. In the electroanalytical field, tyrosinase is used to develop biosensors that exploit its ability to catalyze the oxidation of numerous types of phenolic compounds with antioxidant and neurotransmitter roles. This review critically examines the main tyrosinase immobilization techniques for the development of sensitive electrochemical biosensors. Immobilization strategies are mainly classified according to the degree of reversibility/irreversibility of enzyme binding to the support material. Each tyrosinase immobilization method has advantages and limitations, and its selection depends mainly on the type of support electrode, electrode-modifying nanomaterials, cross-linking agent or surfactants used. Tyrosinase immobilization by cross-linking is characterized by very frequent use with outstanding performance of the developed biosensors. Additionally, research in recent years has focused on new immobilization strategies involving cross-linking, such as cross-linked enzyme aggregates (CLEAs) and magnetic cross-linked enzyme aggregates (mCLEAs). Therefore, it can be considered that cross-linking immobilization is the most feasible and economical approach, also providing the possibility of selecting the reagents used and the order of the immobilization steps, which favor the enhancement of biosensor performance characteristics.

18 June 2020 in Chemosensors
Verified
Journal Article
Open access
PDF file
Alexandra Virginia BounegruAlexandra Virginia Bounegru
Alexandra Virginia Bounegru
Constantin ApetreiConstantin Apetrei
Constantin Apetrei
Caffeic acid may be accurately detected in food supplements by using cyclic voltammetry and carbon screen-printed sensors modified with various nanomaterials. Sensor characterization by cyclic voltammetry in reference solutions has shown that carbon nanotubes or carbon nanofibers significantly improve the sensor response in terms of sensitivity and reversibility. Screen-printed sensors were then used in order to study the electrochemical behavior of caffeic acid in aqueous solution at pH 3.6. A redox process was observed in all cases, which corresponds to a reversible redox process involving the transfer of two electrons and two protons. The role of nanomaterials in the increment of sensor performance characteristics was evidenced. Calibration curves were developed for each sensor, and the detection (LOD) and quantification (LOQ) limits were calculated. Low LOD and LOQ values were obtained, in the 10−7 to 10−9 M range, which demonstrates that the method is feasible for quantification of caffeic acid in real samples. Caffeic acid was quantitatively determined in three food supplements using the most sensitive sensor, namely the carbon nanofiber sensor. The Folin–Ciocalteu spectrophotometric assay was used to validate the results obtained with the sensor. The results obtained by using the voltammetric method were consistent with those obtained by using the spectrophotometric method, with no statistically significant differences between the results obtained at 95% confidence level.

18 April 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
IAIacob Ancuta
Iacob Ancuta
Alexandra Virginia BounegruAlexandra Virginia Bounegru
Alexandra Virginia Bounegru
CICatalina Iticescu
Catalina Iticescu
LGLucian Georgescu
Lucian Georgescu
Constantin ApetreiConstantin Apetrei
Constantin Apetrei
Two electrochemical sensors were developed in this study, with their preparations using two nanomaterials with remarkable properties, namely, carbon nanofibers (CNF) modified with Fe3O4 nanoparticles and multilayer carbon nanotubes (MWCNT) modified with Fe3O4 nanoparticles. The modified screen-printed electrodes (SPE) were thus named SPE/Fe3O4-CNF and SPE/Fe3O4-MWCNT and were used for the simultaneous detection of heavy metals (Cd2+, Pb2+, Cu2+ and Hg2+). The sensors have been spectrometrically and electrochemically characterized. The limits of detection of the SPE/Fe3O4-CNF sensor were 0.0615 μM, 0.0154 μM, 0.0320 μM and 0.0148 μM for Cd2+, Pb2+, Cu2+ and Hg2+, respectively, and 0.2719 μM, 0.3187 μM, 1.0436 μM and 0.9076 μM in the case of the SPE/ Fe3O4-MWCNT sensor (following optimization of the working parameters). Due to the modifying material, the results showed superior performance for the SPE/Fe3O4-CNF sensor, with extended linearity ranges and detection limits in the nanomolar range, compared to those of the SPE/Fe3O4-MWCNT sensor. For the quantification of heavy metal ions Cd2+, Pb2+, Cu2+ and Hg2+ with the SPE/Fe3O4-CNF sensor from real samples, the standard addition method was used because the values obtained for the recovery tests were good. The analysis of surface water samples from the Danube River has shown that the obtained values are significantly lower than the maximum limits allowed according to the quality standards specified by the United States Environmental Protection Agency (USEPA) and those of the World Health Organization (WHO). This research provides a complementary method based on electrochemical sensors for in situ monitoring of surface water quality, representing a useful tool in environmental studies.