Miloš Kostić

Dr. Miloš Kostić

Tecnalia, San Sebastian, Spain
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2022 in IEEE Transactions on Haptics
Verified
Journal Article
Open access
MIMilica Isakovic
Milica Isakovic
JMJovana Malešević
Jovana Malešević
MKMiloš Kostić
Miloš Kostić
Strahinja DosenStrahinja Dosen
Strahinja Dosen
MŠMatija Štrbac
Matija Štrbac
Development of haptic interfaces to enrich augmented and virtual reality with the sense of touch is the next frontier for technological advancement of these systems. Among available technologies, electrotactile stimulation enables design of high-density interfaces that can provide natural-like sensation of touch in interaction with virtual objects. The present study investigates the human perception of electrotactile sensations on fingertips, focusing on the sensation localization in function of the size and position of reference electrode. Ten healthy subjects participated in the study, with the task to mark the sensations elicited by stimulating the index fingertip using an 8-pad electrode. The test systematically explored several configurations of the active (position) and reference (position and size) electrode pads. The results indicated that there was a spreading of perceived sensations across the fingertip, but that they were mostly localized below the active pad. The position and size of the reference electrode were shown to affect the location of the perceived sensations, which can potentially be exploited as an additional parameter to modulate the feedback. The present study demonstrates that the fingertip is a promising target for the delivery of high-resolution feedback.

13 June 2016 in European Journal of Translational Myology
Verified
Journal Article
Open access
PDF file
JMJovana Malešević
Jovana Malešević
MŠMatija Štrbac
Matija Štrbac
MIMilica Isaković
Milica Isaković
VKVladimir Kojić
Vladimir Kojić
LKLjubica Konstantinovic
Ljubica Konstantinovic
TKThierry Keller
Thierry Keller
The purpose of this study was to examine surface motor activation zones for wrist, fingers and thumb extension movements and their temporal change during 20 therapy sessions using advanced multi-pad functional electrical stimulation system. Results from four hemiplegic patients indicate that certain zones have higher probability of eliciting each of the target movements. However, mutual overlap and variations of the zones are present not just between the subjects, but also on the intrasubject level, reflected through these session to session transformations of the selected virtual electrodes. The obtained results could be used as a priori knowledge for semi-automated optimization algorithm and could shorten the time required for calibration of the multi-pad electrode.

14 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MKMiloš Kostić
Miloš Kostić
VKVladimir Kojić
Vladimir Kojić
SISavo Ičagić
Savo Ičagić
Peter Andersson ErsmanPeter Andersson Ersman
Peter Andersson Ersman
MMMohammad Yusuf Shafi Mulla
Mohammad Yusuf Shafi Mulla
MŠMatija Štrbac
Matija Štrbac
This paper presents the first successful implementation of fully printed electronics for flexible and wearable smart multi-pad stimulation electrodes intended for use in medical, sports and lifestyle applications. The smart multi-pad electrodes with the electronic circuits based on organic electrochemical transistor (OECT)-based electronic circuits comprising the 3–8 decoder for active pad selection and high current throughput transistors for switching were produced by multi-layer screen printing. Devices with different architectures of switching transistors were tested in relevant conditions for electrical stimulation applications. An automated testbed with a configurable stimulation source and an adjustable human model equivalent circuit was developed for this purpose. Three of the proposed architectures successfully routed electrical currents of up to 15 mA at an output voltage of 30 V, while one was reliably performing even at 40 V. The presented results demonstrate feasibility of the concept in a range of conditions relevant to several applications of electrical stimulation.

9 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JMJovana Malešević
Jovana Malešević
MKMiloš Kostić
Miloš Kostić
FJFabricio A. Jure
Fabricio A. Jure
Erika G. SpaichErika G. Spaich
Erika G. Spaich
Strahinja DosenStrahinja Dosen
Strahinja Dosen
MŠMatija Štrbac
Matija Štrbac
Electrotactile stimulation is a technology that reproducibly elicits tactile sensations and can be used as an alternative channel to communicate information to the user. The presented work is a part of an effort to develop this technology into an unobtrusive communication tool for first responders. In this study, the aim was to compare the success rate (SR) between discriminating stimulation at six spatial locations (static encoding) and recognizing six spatio-temporal patterns where pads are activated sequentially in a predetermined order (dynamic encoding). Additionally, a procedure for a fast amplitude calibration, that includes a semi-automated initialization and an optional manual adjustment, was employed and evaluated. Twenty subjects, including twelve first responders, participated in the study. The electrode comprising the 3 × 2 matrix of pads was placed on the lateral torso. The results showed that high SRs could be achieved for both types of message encoding after a short learning phase; however, the dynamic approach led to a statistically significant improvement in messages recognition (SR of 93.3%), compared to static stimulation (SR of 83.3%). The proposed calibration procedure was also effective since in 83.8% of the cases the subjects did not need to adjust the stimulation amplitude manually.

27 June 2022 in Artificial Organs
Verified
Journal Article
Open access
FJFabricio A. Jure
Fabricio A. Jure
Erika G. SpaichErika G. Spaich
Erika G. Spaich
JMJovana Malešević
Jovana Malešević
MKMiloš Kostić
Miloš Kostić
MŠMatija Štrbac
Matija Štrbac
Strahinja DosenStrahinja Dosen
Strahinja Dosen
Background Tactile stimulation can be used to convey information to a user in different scenarios while avoiding overloading other senses. Tactile messages can be transmitted as spatial patterns, potentially allowing for a high information throughput. The aim of the present study was to design and test different encoding schemes to determine the best approach for conveying spatial patterns. Methods Encoding schemes with simultaneous (SIM) and sequential pad activation (SEQ) were evaluated, including four SEQ variants designed to potentially facilitate the recognition. In SEQ-col and SEQ-row, the column and row of the activated pad were signified using different frequencies, while SEQ-all and SEQ-all-fast included the activation of all pads where those belonging to the pattern were indicated by changes in frequency (ON pads). The success rate (SR) of the pattern identification and the response time were quantified in 15 participants who recognized 20 patterns delivered through a 3 x 2 pad matrix placed on the lateral torso. Results SIM was not a feasible method to present the patterns (median, 15%; IQR, 5%). The SR improved with SEQ (median, 60%; IQR, 20%) and further increased with additional cues, particularly with SEQ-row (median, 78.3%; IQR, 23.3%) and SEQ-all (median, 96.7%; IQR, 5%). Importantly, the stimulation time of SEQ-all could be decreased without a substantial drop in accuracy (SEQ-all-fast: median, 89.2%; IQR, 19.2%). Conclusions The spatiotemporal stimulation with sequential activation of all pads (SEQ-all) seems to be the method of choice when conveying tactile messages as spatial patterns. This is an important outcome for increasing the information bandwidth of communication through the tactile channel.

3 May 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HFHossam Farag
Hossam Farag
AVAleksandar Vujić
Aleksandar Vujić
MKMiloš Kostić
Miloš Kostić
GBGoran Bijelić
Goran Bijelić
ČSČedomir Stefanović
Čedomir Stefanović
In this paper, we study peak age of information (PAoI) performance of a novel IoT solution for remote health-monitoring of first responders over TErrestrial Trunked RAdio (TETRA) links. The solution features a set of sensors embedded in a smart garment that periodically record and send physiological parameters of first responders to a remote agent. The received data is analyzed by the remote agent, which feeds back notifications and warnings to the first responders in the form of electrotactile stimuli. The communication in the system is performed over the TETRA Short Data Service (SDS), which is the default option for the development of third-party applications and which has rather limited capabilities. The choice of the PAoI as the parameter of interest is motivated by its suitable to measure data freshness in IoT applications with periodic monitoring. We derive closed-form expressions of PAoI for different packet-management schemes allowed by the TETRA standard, and verify the analytical results through extensive simulations under varying message generation rates. Our results provide important insights on the expected PAoI performance, which can be used for the system design guidelines. To the best of our knowledge, this is the first work that analyzes AoI performance of TETRA networks.