Min-Ju Jeon

Dr. Min-Ju Jeon

Chonnam National University
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
MJMin-Ju Jeon
Min-Ju Jeon
This study evaluates the performance of an R744/R404A cascade refrigeration system (CRS) with internal heat exchangers (IHE) in supermarkets. R744 is used as the refrigerant in a low-temperature cycle, and R404A is used as the refrigerant in a high-temperature cycle. In previous studies, there are many studies including theoretical performance analysis of the CRS. However, experimental studies on the CRS are lacking, and experimental research on the R744/R404A system with an IHE is scarce. Therefore, this study provides basic data for optimal refrigeration system design by experimentally evaluating the results of modifying various parameters. The operating parameters considered in this study include subcooling and superheating, condensing and evaporating temperature, cascade evaporation temperature, and IHE efficiency in the R744 low- and R404A high-temperature cycle. The main results are summarized as follows: (1) By applying the results of this study, energy efficiency is achieved by optimizing the overall coefficient of performance (COP) of the CRS, and the refrigerant charge of the R404A cycle is minimized and economic efficiency is also obtained, enabling operation and maintenance as an environment-friendly system. (2) When designing the CRS, finding the cascade evaporation temperature that has the optimum and maximum COP according to the refrigerant combination should be considered with the highest priority.

18 April 2018 in Heat and Mass Transfer
Verified
Journal Article
Closed access
PDF file
CMChang-Uk Moon
Chang-Uk Moon
KCKwang-Hwan Choi
Kwang-Hwan Choi
JYJung-In Yoon
Jung-In Yoon
YKYoung-Bok Kim
Young-Bok Kim
CSChang Hyo Son
Chang Hyo Son
JLJoon-Hyuk Lee
Joon-Hyuk Lee

8 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
MJMin-Ju Jeon
Min-Ju Jeon
This paper examines the exergy efficiency and exergy destruction rate of the R744/R404A cascade refrigeration system (CRS) using an internal heat exchanger in supermarkets according to various conditions affecting the system. A refrigerant of a low-temperature cycle uses R744 and a refrigerant of a high-temperature cycle in the CRS uses R404A. Experiments were conducted by changing various conditions on the high- and low-temperature side, and exergy analysis was performed accordingly. The main results are summarized as follows: (1) the lower the total exergy destruction rate of the CRS, the higher the exergy efficiency of the system, and accordingly the coefficient of performance (COP) of the system is also improved. (2) In the CRS, since the optimum cascade evaporation temperature exists (about −16 °C), it can be said that the limit point, that is, the cascade evaporation temperature with the maximum COP of the system, is the optimum point at about −16 °C. Therefore, at this optimum point, the exergy destruction rate of the cascade heat exchanger becomes the minimum. In other words, it should be noted that when the cascade evaporation temperature is the optimum point, the exergy destruction rate of the R744 compressor and the cascade heat exchanger is minimal. The purpose of this study is to provide basic design data by analyzing the exergy characteristics according to various conditions on the high- and low-temperature side for optimal design of a CRS to which R744 is applied.

8 October 2018 in Heat and Mass Transfer
Verified
Journal Article
Closed access
PDF file
WYWen-Bin Yi
Wen-Bin Yi
KCKwang-Hwan Choi
Kwang-Hwan Choi
JYJung-In Yoon
Jung-In Yoon
CSChang Hyo Son
Chang Hyo Son
SHSoo-Jung Ha
Soo-Jung Ha
MJMin-Ju Jeon
Min-Ju Jeon

25 October 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HLHyun-Kyung Lee
Hyun-Kyung Lee
KCKwang-Hwan Choi
Kwang-Hwan Choi
JYJung-In Yoon
Jung-In Yoon
CMChoon-Geun MOON
Choon-Geun MOON
MJMin-Ju Jeon
Min-Ju Jeon
CSChang Hyo Son
Chang Hyo Son
In this study, to investigate the performance characteristics of a seawater ice-making device, using a scraped surface double tube evaporator, experiments were conducted under various operating conditions, including inlet temperature and flow rate of seawater, evaporating temperature, and scraper rotation speed. The main results are summarized as follows: (1) The section where stable ice making is possible, is determined by the inlet temperature and the flow rate range of seawater. By controlling the flow rate of seawater, the ice packing factor (IPF) of the device can be adjusted from 0.3 to 14.7%. (2) The IPF increases in cases where the evaporating temperature decreases linearly, until −13 °C. As the temperature of refrigerant that flows into the evaporator changes, the IPF is changed. Consideration is required for these connections. (3) The IPF increases when speeding up the scraper. The minimum rotating speed of the scraper was 350 rpm in these experiments. Optimum operating conditions for the seawater ice slurry maker are established through experiments. These results will be considered as important data for designing a slurry type seawater ice-making device.

14 October 2016 in Heat and Mass Transfer
Verified
Journal Article
Closed access
PDF file
JYJung-In Yoon
Jung-In Yoon
CSChang Hyo Son
Chang Hyo Son
SJSuk-Ho Jung
Suk-Ho Jung
MJMin-Ju Jeon
Min-Ju Jeon
DYDong-Il Yang
Dong-Il Yang