Mingzhen Li

Dr. Mingzhen Li

Nantong University, Nantong, Jiangsu, China
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MLMingzhen Li
Mingzhen Li
CZChengke Zhou
Chengke Zhou
WZWenjun Zhou
Wenjun Zhou
This two-part paper proposes a revised method for calculating HV (High Voltage) cable sheath currents, and for fault location of cross-bonded HV cable systems. The equivalent circuit and the cable impedance per unit length under short-circuit fault conditions are revised from those under non-fault conditions. Part 1 of this paper proposes a revised phasor domain mathematical model for the sheath current calculation under fault conditions, following demonstration that short-circuit faults can cause changes in the equivalent circuit of the cable metal sheath, and causing changes in the cable impedance per unit length. The calculation results, as given in a case study, show that there exists a unique relation between the fault position and the sheath fault currents, making it possible to locate a fault by analyzing the characteristics of the sheath currents during a fault. Part 2 of the paper focuses on the fault location method via sheath current monitoring.

5 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MLMingzhen Li
Mingzhen Li
JLJianming Liu
Jianming Liu
TZTao Zhu
Tao Zhu
WZWenjun Zhou
Wenjun Zhou
CZChengke Zhou
Chengke Zhou
In order to improve the practice in maintenance of power cables, this paper proposes a novel traveling-wave-based fault location method improved by unsupervised learning. The improvement mainly lies in the identification of the arrival time of the traveling wave. The proposed approach consists of four steps: (1) The traveling wave associated with the sheath currents of the cables are grouped in a matrix; (2) the use of dimensionality reduction by t-SNE (t-distributed Stochastic Neighbor Embedding) to reconstruct the matrix features in a low dimension; (3) application of the DBSCAN (density-based spatial clustering of applications with noise) clustering to cluster the sample points by the closeness of the sample distribution; (4) the arrival time of the traveling wave can be identified by searching for the maximum slope point of the non-noise cluster with the fewest samples. Simulations and calculations have been carried out for both HV (high voltage) and MV (medium voltage) cables. Results indicate that the arrival time of the traveling wave can be identified for both HV cables and MV cables with/without noise, and the method is suitable with few random time errors of the recorded data. A lab-based experiment was carried out to validate the proposed method and helped to prove the effectiveness of the clustering and the fault location.

2 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
GLGen Li
Gen Li
JCJie Chen
Jie Chen
HLHongze Li
Hongze Li
LHLibin Hu
Libin Hu
WZWenjun Zhou
Wenjun Zhou
MLMingzhen Li
Mingzhen Li
Power cable condition diagnosis and deterioration location rely on signatures of aging characteristics which precede the final breakdown. The purpose of this study was to investigate how to diagnose and locate the aging and/or deterioration of power cables through the analysis of the impedance spectroscopy. The concepts of the reference frequency and characteristic frequency of cable impedance spectroscopy are defined for the first time. Based on the reference frequency, the optimal frequency range for analysis of impedance spectroscopy can be determined, whilst based on characteristic frequency, a set of criteria for assessing cable conditions are examined and established. The solution proposed in this paper has the advantage of being easier to implement than the previously reported “broadband” impedance spectroscopy methods, as it helps to reduce the frequency range for measurement instrumentations; the proposed method also does not need the measurements of the parameters of the cable being tested.

1 December 2019 in High Voltage
Verified
Journal Article
Open access
PDF file
MLMingzhen Li
Mingzhen Li
CZChengke Zhou
Chengke Zhou
WZWenjun Zhou
Wenjun Zhou
JZJun Zhang
Jun Zhang
LZLiang Zhang
Liang Zhang
LYLeiming Yao
Leiming Yao
Among all failures in cable circuits, the failure rate of cable joints is much higher than that in cable bodies. In an effort to reduce cable failure rates and improve the reliability of power cable systems, this article studies the possibility of increasing the length of a cable section and thus reducing the number of cable joints via alternative sheath bonding methods. As the maximum length of an electrical cable section is governed by the permissible sheath standing voltage, this article first proposes a precise sheath voltage calculation model without approximations and simplifications. The sheath voltage per unit length has then been calculated for each bonding method using the proposed model. The maximum length of a cable section has then been calculated, based on the permissible sheath standing voltage, for the various sheath bonding methods. Results show that the traditional 500‐m minor section length could be increased to 2.21 km by using the single‐point bonding method. The maximum distance can be further lengthened by increasing the physical spacing among the three‐phase cables. The economic comparison for each bonding method has also been made. Finally, the proposed method has been applied to a HV cable circuit already in operation, and the operational data confirms the feasibility.

22 January 2025 in Materials
Verified
Journal Article
Open access
PDF file
CLChenying Li
Chenying Li
XTXiao Tan
Xiao Tan
LLLiguo Liu
Liguo Liu
WZWei Zhang
Wei Zhang
QYQiming Yang
Qiming Yang
Zaixin SongZaixin Song
Zaixin Song
The present study investigates the relationship between the near-infrared (NIR) spectral characteristics of cross-linked polyethylene (XLPE) insulation materials and their macroscopic properties, with the aim of establishing a reference framework for non-destructive material aging analysis. Accelerated thermal aging tests were conducted on samples of XLPE cables. These samples underwent Fourier-transform infrared spectroscopy (FTIR), elongation at break (EAB), and tensile strength (TS) tests. The temporal variation curves of the carbonyl index (CI), EAB, and TS were obtained at aging temperatures of 105 °C, 135 °C, 155 °C, and 180 °C. Additionally, NIR spectroscopy was performed on the aged XLPE samples, producing absorbance curves corresponding to different aging times at these temperatures. The absorption peaks of ‘C-H (-CH2-)’ (1730 nm/1764 nm) were analyzed to determine their temporal variation patterns. Finally, a correlation analysis was conducted between the NIR results and those of the FTIR, EAB, and TS tests, revealing numerical relationships between NIR characteristic peaks and FTIR, EAB, and TS data. These quantified correlations demonstrate that NIR can effectively represent macroscopic mechanical properties, thereby simplifying the procedures for monitoring material aging and providing valuable results without requiring destructive testing. Results indicate that there is a certain feasibility in replacing traditional cable aging tests with NIR.

10 April 2023 in IEEE Access
Verified
Journal Article
Open access
MLMingzhen Li
Mingzhen Li
RYRuijun Yuan
Ruijun Yuan
JCJie Chen
Jie Chen
LHLibin Hu
Libin Hu
CLChenying Li
Chenying Li
XZXinsong Zhang
Xinsong Zhang
In order to explore the feasibility of impedance spectroscopy in the application of online diagnosis of aging and deterioration of medium voltage (MV) three-core cables, based on the theory of transmission line equation, an aging and deterioration model of the MV three-core cable has been established. The impedance spectroscopy of the cable head-end under healthy and different aging and degradation states has been simulated and analyzed. Further, the effects the extent of aging, local deterioration size and position, line length, load rate and other factors on the impedance spectroscopy have been studied. Based on the influence of the various factors on the impedance spectroscopy, a set of aging and deterioration diagnosis procedures and methods are proposed. The simulation results indicate that the impedance spectroscopies of healthy state and different aging and/or deterioration states have certain characteristics. These characteristics can be determined by specific criterion indicators such as the monotonous decrease of the value of the resonance peaks and the phase amplitudes, the value of the resonance peaks, and the eigen propagation frequency, etc. Therefore, impedance spectroscopy has broad application prospects for online diagnosis of aging and deterioration of MV three-core cable.