Mohamed Adel

Dr. Mohamed Adel

Department of Mechatronics and Robotics, Egypt-Japan University of Science and Technology, Alexandria, Al Iskandarīyah, Egypt
+1
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2024 in Biomedical Microdevices
Verified
Journal Article
Open access
PDF file
Mohamed AdelMohamed Adel
Mohamed Adel
AAAhmed Allam
Ahmed Allam
ASAshraf E. Sayour
Ashraf E. Sayour
HRHani F. Ragai
Hani F. Ragai
SUShinjiro Umezu
Shinjiro Umezu
AEAhmed M. R. Fath El-Bab
Ahmed M. R. Fath El-Bab
Quartz crystal microbalance (QCM) is a versatile sensing platform that has gained increasing attention for its use in bioapplications due to its high sensitivity, real-time measurement capabilities, and label-free detection. This article presents a portable QCM system for liquid biosensing that uses a modified Hartley oscillator to drive 14 mm-diameter commercial QCM sensors. The system is designed to be low-cost, easy to use, and highly sensitive, making it ideal for various bioapplications. A new flow cell design to deliver samples to the surface of the sensor has been designed, fabricated, and tested. For portability and miniaturization purposes, a micropump-based pumping system is used in the current system. The system has a built-in temperature controller allowing for accurate frequency measurements. In addition, the system can be used in benchtop mode. The capability of the present system to be used in liquid biosensing is demonstrated through an experimental test for sensitivity to changes in the viscosity of glycerol samples. It was found to have a sensitivity of 263.51 Hz/mPa.s using a 10 MHz QCM sensor. Future work regarding potential applications was suggested.

30 June 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
Mohamed AdelMohamed Adel
Mohamed Adel
AAAhmed Allam
Ahmed Allam
ASAshraf Ezz Eldeen Sayour
Ashraf Ezz Eldeen Sayour
HRHani Fikry Ragai
Hani Fikry Ragai
SUShinjiro Umezu
Shinjiro Umezu
AEAhmed M. R. Fath El-Bab
Ahmed M. R. Fath El-Bab
Trapezoidal cross-sectional spiral microfluidic channels showed high resolution and throughput in cell separation in bio-applications. The main challenges are the complexity and high cost of the fabrication process of trapezoidal cross-sectional channels on the micro-scale. In this work, we present the application of grayscale in microfluidic channel design to overcome the complexity of the fabrication process. We also use direct engraving with a CO2 laser beam on polymethyl methacrylate (PMMA) material to drastically reduce the microfluidic chip’s cost (to <30 cents) and fabrication time (to 20 min). The capability of the present fabrication methodology for cell sorting applications is demonstrated through experimental tests for the separation of white blood cells (WBCs) from whole blood at different dilution factors. The experimental results indicated that an 800 µL/min flow rate provided the optimal separation efficiency using the fabricated chip. A 90.14% separation efficiency at 1% hematocrit diluted blood sample was reported.

8 February 2024 in Engineering Research Express
Verified
Journal Article
Closed access
Mohamed AdelMohamed Adel
Mohamed Adel
AAAhmed Allam
Ahmed Allam
ASAshraf E Sayour
Ashraf E Sayour
HRHani F Ragai
Hani F Ragai
SUShinjiro Umezu
Shinjiro Umezu
AEAhmed M R Fath El-Bab
Ahmed M R Fath El-Bab
Quartz crystal microbalance (QCM) is a powerful sensing technique widely used in various applications, including biosensing, chemical analysis, and material science. In in-liquid applications, QCM measurements are susceptible to fluctuations in fluid flow rate, which can introduce unwanted noise and compromise the accuracy and reliability of the measurements. In this work, we present an approach to enhance the stability of QCM measurements by utilizing a microfluidic flow stabilizer. The flow stabilizer is designed to minimize flow rate fluctuations, thereby reducing the impact of hydrodynamic effects on the QCM frequency response. We employ a comprehensive methodology that combines computational fluid dynamics (CFD) simulations using ANSYS Fluent software, microfabrication, and experimental testing to evaluate the effectiveness of the flow stabilizer in mitigating flow-induced fluctuations and improving the reliability of QCM measurements. For fabrication, we use direct engraving with a CO2 laser beam on polymethyl methacrylate (PMMA) material to drastically reduce the fabrication cost (to <40 cents) and fabrication time (to 35 min) of the microfluidic chip. Two different designs have been presented and tested: one with a single air reservoir and the other with two reservoirs. Two distinct setups employing a peristaltic pump and a micropump, along with a high fundamental frequency of 50 MHz QCM sensor, were utilized for comprehensive testing in this study. The experimental results demonstrated that the first and second designs of the microfluidic flow stabilizer effectively reduced the fluctuation amplitude in QCM measurements from 100% (input) to 23% and 19% (output), respectively.

1 January 2019 in International Journal of Renewable Energy Research
Verified
Journal Article
Closed access
PDF file
Mohamed AdelMohamed Adel
Mohamed Adel
APAdrian Peã±A-Lapuente
Adrian Peã±A-Lapuente
MRMohamed Rady
Mohamed Rady
AHAlaa Hamdy
Alaa Hamdy
Development of a New High Dynamic Range Technique for Solar Flux Analysis Using Double-CCD Optical Camera

11 March 2026 in Materials & Design
Verified
Journal Article
Open access
ZZZe Zhang
Ze Zhang
Mohamed AdelMohamed Adel
Mohamed Adel
JHJianxian He
Jianxian He
YLYannan Li
Yannan Li
CXChaolun Xu
Chaolun Xu
SUShinjiro Umezu
Shinjiro Umezu

1 January 2021 in International Journal of Renewable Energy Research
Verified
Journal Article
Closed access
PDF file
Mohamed AdelMohamed Adel
Mohamed Adel
APAdrian Peña-Lapuente
Adrian Peña-Lapuente
MRMohamed Rady
Mohamed Rady
AHAlaa Hamdy
Alaa Hamdy
In central tower concentrated solar power plants, the concentrated flux distribution at the receiver is controlled by the aiming strategy of thousands of heliostats in the field to accomplish the specific requirements of solar-thermal conversion processes. The main goal of this work is to evaluate the reflected solar flux from a heliostat or from a group of heliostats on a calibration target. The solar flux map at the target receiver is constructed using the information embedded in a captured high dynamic range image of the evaluated scene. In the present article, a methodology has been proposed to evaluate the optical performance of solar central receiver systems in terms of beam accuracy and optical quality of reflected light on calibration target. The developed system is a simple, automatic and effective tool used to accurately analyse the reflected solar flux without limitations of previous methods, such as using specific type of calibration target. The capability of the present methodology for accurate analysis is demonstrated through experimental indoor and outdoor tests. https://dorl.net/dor/20.1001.1.13090127.2021.11.2.39.8