Mohammed Ali Alnafea

Prof. Dr. Mohammed Ali Alnafea

King Saud University, Riyadh, Ar Riyāḑ, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2015 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
AFAchraf Al Faraj
Achraf Al Faraj
ASAsma Sultana Shaik
Asma Sultana Shaik
Mohammed Ali AlnafeaMohammed Ali Alnafea
Mohammed Ali Alnafea
Alveolar macrophages, with their high functional plasticity, were reported to orchestrate the induction and resolution of inflammatory processes in chronic pulmonary diseases. Noninvasive imaging modalities that offer simultaneous monitoring of inflammation progression and tracking of macrophages subpopulations involved in the inflammatory cascade, can provide an ideal and specific diagnostic tool to visualize the action mechanism in its initial stages. Therefore, the purpose of the current study was to evaluate the role of M1 and M2 macrophages in the resolution of lipopolysaccharide (LPS)-induced lung inflammation and monitor this process using noninvasive free-breathing MRI and CT protocols. Bone-marrow derived macrophages were first polarized to M1 and M2 macrophages and then labeled with superparamagnetic iron oxide nanoparticles. BALB/c mice with lung inflammation received an intrapulmonary instillation of these ex vivo polarized M1 or M2 macrophages. The biodistribution of macrophages subpopulations and the subsequent resolution of lung inflammation were noninvasively monitored using MRI and micro-CT. Confirmatory immunohistochemistry analyses were performed on lung tissue sections using specific macrophage markers. As expected, large inflammatory areas noninvasively imaged using pulmonary MR and micro-CT were observed within the lungs following LPS challenge. Subsequent intrapulmonary administration of M1 and M2 macrophages resulted in a significant decrease in inflammation starting from 72 h. Confirmatory immunohistochemistry analyses established a progression of lung inflammation with LPS and its subsequent reduction with both macrophages subsets. An enhanced resolution of inflammation was observed with M2 macrophages compared to M1. The current study demonstrated that ex vivo polarized macrophages decreased LPS-induced lung inflammation. Noninvasive free-breathing MR and CT imaging protocols enabled efficient monitoring of progression and resolution of lung inflammation.

23 March 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
RIRasha Itani
Rasha Itani
Mohammed Ali AlnafeaMohammed Ali Alnafea
Mohammed Ali Alnafea
MTMaya Tannoury
Maya Tannoury
SHSouheil Hallit
Souheil Hallit
AFAchraf Al Faraj
Achraf Al Faraj
With the novel coronavirus disease 2019 (COVID-19) pandemic, the need for radiologic procedures is increasing for the effective diagnosis and follow-up of pulmonary diseases. There is an immense load on the radiographers’ shoulders to cope with all the challenges associated with the pandemic. However, amidst this crisis, Lebanese radiographers are also suffering from a socioeconomic crisis and record hyperinflation that have posed additional challenges. A cross-sectional study was conducted among registered Lebanese radiographers to assess the general, workplace conditions, health and safety, mental/psychologic, financial, and skill/knowledge development impacts. Despite applying an adapted safety protocol, institutions are neither providing free RT-PCR testing to their staff nor showing adequate support for infected staff members, thus causing distress about contracting the virus from the workplace. Aggravated by the deteriorating economic situation that affected the radiographers financially, they additionally suffer from severe occupational physical and mental burnout. Regardless of that, they used their free time during the lockdown for skill/knowledge development and have performed many recreational activities. This cross-sectional study highlighted the different ways the pandemic has impacted the radiographers: physically, psychologically, and financially. It aimed to shed light on what these frontline heroes are passing through in the midst of all these unprecedented crises.

27 April 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
NGNashaat Ghaith
Nashaat Ghaith
BMBassem Malaeb
Bassem Malaeb
RIRasha Itani
Rasha Itani
Mohammed Ali AlnafeaMohammed Ali Alnafea
Mohammed Ali Alnafea
AFAchraf Al Faraj
Achraf Al Faraj
Diabetes is considered one of the major causes of chronic kidney disease (CKD), affecting renal blood vessels and nerves. Diagnosis of CKD by traditional biochemical serum and blood analyses is insufficient and insensitive, thus requiring the development of a more robust technique. This novel study aims to propose a new method for the accurate diagnosis of CKD, quantification of kidney damage, and its prognosis by physicians by measuring the kidney volume on computed tomography (CT). In total, 251 patients were enrolled in this retrospective study. They were divided into four groups: control, patients having diabetes, patients having CKD, and patients having both diabetes and CKD. Results showed that kidney volume correlated negatively with both GFR and HbA1C on CT images, in addition to decreasing faster in males than females. Moreover, HbA1C was shown to correlate positively with creatinine and negatively with GFR. Finally, GFR was more robust than creatinine when correlated with age. The association between kidney volume with GFR and HbA1c can be used to accurately anticipate kidney volume in established CKD on CT scan, especially in resource-poor settings. Furthermore, HbA1C can serve as a powerful biomarker for studying renal function in diabetic CKD patients as it correlates with creatinine and GFR.

18 October 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
KHALID HUSSAINKHALID HUSSAIN
KHALID HUSSAIN
Mohammed Ali AlnafeaMohammed Ali Alnafea
Mohammed Ali Alnafea
MSM. Iqbal Saripan
M. Iqbal Saripan
DMDjelloul Mahboub
Djelloul Mahboub
RMRozi Mahmud
Rozi Mahmud
XDXianling Dong
Xianling Dong
Coded Aperture (CA) imaging has recently been used in nuclear medicine, but still, there is no commercial SPECT imaging camera based on CA for cancer detection. The literature is rich in examples of using the CA for planar and thin 3D imaging. However, thick 3D reconstruction is still challenging for small lesion detection. This paper presents the results of mosaic modified uniformly redundant array (MURA) mask/antimask CA combined with a maximum-likelihood expectation-maximization (MLEM) algorithm. The MLEM is an iterative algorithm applied to a mosaic MURA CA mask/antimask for 3D anthropomorphic breast phantom reconstruction, slice by slice. The difference between the mask and the antimask suppresses the background noise to enhance the quality of reconstructed images. Furthermore, all reconstructed slices are stacked to form a 3D breast phantom image from single-projection data. The results of phantom reconstruction with 8 mm, 6 mm, 4 mm, and 3 mm lesions are presented. Moreover, the proposed SPECT imaging camera can reconstruct a 3D breast phantom from single-projection data of the patient’s scanning. To assess the quality of lesions in the reconstructed images, the contrast-to-background ratio (CBR), the peak signal-to-noise ratio (PSNR) and mean square error (MSE) were measured.

17 January 2018
Verified
Book Chapter
Open access
PDF file
Mohammed Ali AlnafeaMohammed Ali Alnafea
Mohammed Ali Alnafea
Cancer is a disease that starts in a localized organ or tissue and then grows out of control. Breast cancer is an important health problem as in the Western world; it is the second most frequent cause of cancer death in women (after lung cancer). The incidence rate, however, rises dramatically over the age of 50 years. This is may be due to several risk factors, such as family history, genetics, early menstruation, late menopause, and other factors, that have not yet been identified. The problems of breast diseases have prompted global governments to put constant efforts to increase patient's recovery level against this disease. Early and accurate detection with mass screening programs helps improves a woman's chances for successful treatment. It also minimizes pain, suffering, and anxiety that surround patients and their families. The current and the most cost-effective technique used for screening and diagnosis of breast cancer is X-ray mammography. It is the state-of-the-art for earlier detection to improve both prognosis and survival rate. This is may be due to its good availability, high sensitivity, and relatively low cost/patient. The goal of this chapter is to introduce the problems caused by breast cancer. Starting with an overview of the requirement for breast tumor imaging and the diagnostic techniques used for breast cancer assessment are briefly described, highlighting the advantages and disadvantages of each technique. In addition, the problems associated with a relatively new functional breast imaging technique namely scintimammography were introduced and discussed. The intention that the chapter provide the reader with sufficient background on the available diagnostic techniques of breast tumor imaging approach, as well as an overview of the literature.

1 January 2006
Verified
Conference Paper
Open access
Mohammed Ali AlnafeaMohammed Ali Alnafea
Mohammed Ali Alnafea
KWK. Wells
K. Wells
MGM. Guy
M. Guy
NSN. M. Spyrou
N. M. Spyrou
In this work we study the form of artifacts arising with near-field imaging geometries associated with using coded apertures for scintimammography (SM) using a combination of Monte Carlo simulation (MCS), pseudo-ray tracing (PRT) and a new, but simple approach called binary mask shift. The latter method predicted the shape artifacts that are due to off-axis sources and finite size of the object but ignores the effect of varying the angle of incidence of the gamma-rays. The background artifact pattern produced by uniform 2D and 3D source objects of different sizes using a PRT method compared with the corresponding data obtained with MCS suggest that both methods produce striking similarities. From these results we are encouraged to believe that the so-called near field distortion observed with distributed planar and 3D sources, as might be found in SM using coded apertures, can be easily predicted and corrected.