Najamuddin Naveed Khaja

Mr. Najamuddin Naveed Khaja

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2025 in Electrochimica Acta
Verified
Journal Article
Open access
SKSreerag Kaaliveetil
Sreerag Kaaliveetil
NMNiranjan Haridas Menon
Niranjan Haridas Menon
NKNajamuddin Naveed Khaja
Najamuddin Naveed Khaja
SYSushma Yadav
Sushma Yadav
SBSagnik Basuray
Sagnik Basuray
JYJoshua Young
Joshua Young

21 April 2026 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
NKNajamuddin Naveed Khaja
Najamuddin Naveed Khaja
SKSreerag Kaaliveetil
Sreerag Kaaliveetil
NMNiranjan Haridas Menon
Niranjan Haridas Menon
SYSushma Yadav
Sushma Yadav
CSChetan Prakash Sharma
Chetan Prakash Sharma
Sagnik BasuraySagnik Basuray
Sagnik Basuray
Membrane fouling remains a major challenge in water treatment, biomedical, and pharmaceutical fields, yet understanding its mechanisms at the membrane interface remains difficult. Herein, we report a 3D impedimetric microfluidic membrane-mimic (IM3) cassette that integrates a porous membrane between microfluidic channels for real-time fouling investigation via electrochemical impedance spectroscopy (EIS). System validation using fluorescein and KCl electrolytes demonstrated reproducible charge-transfer resistance (Rct) values and confirmed cassette robustness. Colloidal fouling studies using 800 nm polystyrene latex (PS) beads demonstrated a clear concentration-dependent behavior. High particle loading (105 particles/mL) caused rapid, severe impedance increases, indicating extensive pore blockage and cake layer formation. Low loading (101 particles/mL) showed minimal changes, suggesting negligible fouling, as confirmed by scanning electron microscopy. The distribution of relaxation times (DRT) analysis revealed a single dominant relaxation peak at 10-2 s that grew stronger as fouling severity increased, confirming that pore blockage raised interfacial resistance through a unified charge-transfer mechanism rather than caused diffusion-limited processes. A quantitative fouling model using EIS-measured Rct changes captured temporal and concentration dependencies through an exponential growth framework. Maximum fouling extent (Fmax) increased significantly with particle concentration (30% at 101 to 215% at 105 particles/mL), demonstrating concentration-dependent pore blockage. The fouling rate constant (k) showed weak concentration dependence and plateaued at high loadings, indicating the limitation by available deposition sites rather than particle transport. These findings show that for PS beads, fouling is mainly governed by the extent of surface deposition (driven by concentration) rather than by the particle arrival rate (controlled by kinetics). The developed modular IM3 cassette enables customization of different membranes, channel geometries, and flow configurations. These results establish a quantitative framework linking EIS data to physically meaningful fouling phenomena, offering a versatile platform for the mechanistic investigation of dynamic membrane fouling behavior under varying particulate conditions.

3 July 2024 in Chemosensors
Verified
Journal Article
Open access
PDF file
SKSreerag Kaaliveetil
Sreerag Kaaliveetil
NKNajamuddin Naveed Khaja
Najamuddin Naveed Khaja
NMNiranjan Haridas Menon
Niranjan Haridas Menon
Sagnik BasuraySagnik Basuray
Sagnik Basuray
Practical gas–liquid interfacing is paramount in microfluidic technology, particularly in developing microfluidic gas sensors. We have created an easily replicable membrane-based closed microfluidic platform (MB-MP) to achieve in situ gas–liquid contact for low-resource settings. We have fabricated the MB-MP using readily available materials like double-sided tape or parafilm without conventional soft lithographic techniques. The response characteristics of the MB-MP are studied using CO2 as the model gas and bromothymol blue dye as the sensing material. The dye’s color change, indicative of pH shifts due to CO2 absorption, is captured with a digital microscope and analyzed via the ImageJ software package v1.54g. The response shows saturation and regeneration parts when cycled between CO2 and N2, respectively. Experiments are conducted to investigate the response characteristics and saturation rate under different conditions, including changes in volumetric flow rate, gas stream velocity, and dye solution volume. We observe experimentally that an increase in volumetric flow rate decreases the delay and increases the saturation rate of the response, surpassing the impact of the gas stream’s increased velocity. Furthermore, increasing the dye volume results in an exponential decrease in the saturation rate and an increase in the delay. These insights are essential for optimizing the platform’s response for point-of-use applications.

7 December 2025 in Electrochimica Acta
Verified
Journal Article
Closed access
SKSreerag Kaaliveetil
Sreerag Kaaliveetil
NMNiranjan Haridas Menon
Niranjan Haridas Menon
NKNajamuddin Naveed Khaja
Najamuddin Naveed Khaja
SYSushma Yadav
Sushma Yadav
SDSaudagar Dongare
Saudagar Dongare
Sagnik BasuraySagnik Basuray
Sagnik Basuray

2 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
NMNiranjan Haridas Menon
Niranjan Haridas Menon
NGNico Giovannetti
Nico Giovannetti
SKSreerag Kaaliveetil
Sreerag Kaaliveetil
NKNajamuddin Naveed Khaja
Najamuddin Naveed Khaja
SYSushma Yadav
Sushma Yadav
Sagnik BasuraySagnik Basuray
Sagnik Basuray
Measuring consistent impedimetric signals under flow remains a persistent challenge in microfluidic electrochemical impedance spectroscopy (EIS) due to dynamic signal drift. This becomes even more challenging in the presence of redox probes or complicated electrode geometry. Such drift complicates data analysis and undermines the reliability of the impedance sensor. As its underlying origins are insufficiently understood, drift corrections are not implemented, leading to false positives and false negatives. In this work, we investigate the sources of this drift in the EIS signal of a porous, flow-through microfluidic sensor with three-dimensional electrodes. For empty channels under flow conditions, unexpected drift was observed only in the presence of a redox probe, highlighting the central role of redox-mediated interfacial processes. Surprisingly, even in the absence of a redox probe, packed channels still exhibited significant electrochemical drift. Comparing EIS signals from packed and empty channels with and without the redox couple, we can decouple the contributions of flow, porous packing, and faradaic reactions on the origins of the drift. We hypothesize that the drift arises from the combined effects of convection, interfacial double-layer formation within the porous packing, and redox probe–electrode interactions. A new root-mean-square error (RMSE)–based analysis framework is introduced to quantify drift and determine stable measurement windows, independent of sensor geometry or equivalent circuits. This algorithm is validated using single-stranded DNA detection that clearly illustrates that drift correction in EIS data significantly improves measurement reliability, and ultimately sensor selectivity, leading to fewer false positives or false negatives.

25 July 2026 in Chemosensors
Verified
Journal Article
Open access
PDF file
NKNajamuddin Naveed Khaja
Najamuddin Naveed Khaja
SYSushma Yadav
Sushma Yadav
NMNiranjan Haridas Menon
Niranjan Haridas Menon
SKSreerag Kaaliveetil
Sreerag Kaaliveetil
GLGuangliang Liu
Guangliang Liu
Sagnik BasuraySagnik Basuray
Sagnik Basuray
The demand for a versatile and portable point-of-use (POU) sensor platform has surged due to the pandemic, especially in countries with limited medical laboratory facilities. We recently unveiled a portable, non-planar, interdigitated, flow-through, porous electrode platform that automatically measures electrochemical impedance spectroscopy (EIS) signals from various biomarkers. However, the packed powder exhibited a loss of performance over time due to displacement, leaching, and poor stability. Herein, we modified the packing strategy by synthesizing the sensing material within the channel, thereby improving adhesion, structural integrity, and stability. Leveraging the exceptional thermal stability, mechanical strength, and chemical resistance of polyimide (PI), we developed a novel fabrication approach that combines liquid-phase inversion and breath-figure techniques to create a porous PI manifold with single-walled carbon nanotubes (SWCNTs) under varying humidity conditions. Scanning electron microscope (SEM) analysis revealed that lower relative humidity (RH) conditions yield larger but less uniformly distributed pores, leading to increased channel pressure. The manifold demonstrated exceptional stability under rigorous flow conditions, withstanding a high flow rate of 30 µL/min while maintaining consistent pressure-EIS responses. The device produced a measurable proof-of-concept impedance response following exposure to a femtomolar concentration of complementary target ssDNA in 1× PBS within 15 min. A formal limit of detection was not determined in the present study. We developed a mechanically stable sensor design with improved durability under repeated flow conditions by systematically optimizing synthesis conditions and manifold configuration. This innovative fabrication strategy demonstrates the importance of packing methodology in sensor design and paves the way for robust, scalable, and efficient diagnostic solutions in resource-limited settings.