Krzysztof Nepelski

Dr. Krzysztof Nepelski

Lublin University of Technology, Lublin, Lubelskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KNKrzysztof Nepelski
Krzysztof Nepelski
Agnieszka LalAgnieszka Lal
Agnieszka Lal
Loess soils were created by the wind transporting particles with later or in parallel occurred protogenetic, syngenetic and epigenetic processes. As a result, various genetic processes affected loesses strength and deformability characteristics. The aim of the study is to estimate the main CPT parameters of loess subsoil in Lublin area according to divided facies. The subsoil in the area of the Nałęczowski Plateau, where Lublin is located, consists mainly of loess from aeolian and aeolian–diluvial facies, and in the deeper parts—from aeolian–alluvial facies. Most of the results obtained for the aeolian facies at the level of qc in the range from 4.5 to 8.0 MPa indicate that these soils are a good load-bearing substrate for building structures. Cone resistances mostly at the level of 1.5–4.0 MPa for the diluvial and alluvial facies confirm that these facies constitute less favorable foundation conditions. The reduced resistance results mainly from the increased water content in ground pores. It is especially the soils of the diluvial facies that provide unfavorable foundation conditions, as they occur near the surface. Genetic processes are a very important element that should be taken into account in engineering research.

3 December 2017 in Budownictwo i Architektura
Verified
Journal Article
Open access
PDF file
ŁBŁukasz Borowski
Łukasz Borowski
Agnieszka LalAgnieszka Lal
Agnieszka Lal
KNKrzysztof Nepelski
Krzysztof Nepelski
W niniejszej pracy zawarto rozważania dotyczące możliwych przyczyn nadmiernego osiadania znaków osnowy geodezyjnej. Do analiz wybrano znaki ziemne osnowy wysokościowej typu 75a i b. Przeprowadzono analizę obliczeniową osiadania znaków osnowy geodezyjnej, pracujących w różnych warunkach gruntowych oraz w dwóch złożonych obciążeniach. W celu uwzględnienia w obliczeniach najbliższych rzeczywistym warunków współpracy pomiędzy elementami osnowy geodezyjnej, a ośrodkiem gruntowym, modyfikowano przyjmowane parametry. Uzyskane wyniki porównywano z zaobserwowanymi w powiecie kętrzyńskim w trakcie transformacji układu wysokościowego z Kronsztadt’60 na Kronsztadt’86. Wynikiem prac jest określenie możliwych zmian osnowy wysokościowej, w okresie pomiędzy kampaniami pomiarowymi (około 20 lat).

24 January 2020 in Budownictwo i Architektura
Verified
Journal Article
Open access
PDF file
KNKrzysztof Nepelski
Krzysztof Nepelski
W pracy przedstawiono przykład interpretacji badań polowych, sondowań statycznych CPT oraz testów dylatometrem Marchettiego SDMT. Badania przeprowadzono na gruntach lessowych ma terenie Lublina. Wykonano 4 testy CPT oraz 4 sejsmiczne testy SDMT. Opisano metodę wyprowadzania parametrów geotechnicznych z badań polowych. W szczególności przeanalizowano formuły do obliczania modułu ściśliwości na podstawie oporu stożka qc. Część z parametrów zinterpretowano z wykorzystaniem własnych formuł. Porównano wartości parametrów odkształceniowych oszacowanych odmiennymi metodami, dla różnych zakresów odkształceń.

14 July 2020 in Open Engineering
Verified
Journal Article
Open access
PDF file
KNKrzysztof Nepelski
Krzysztof Nepelski
In order to correctly model the behaviour of a building under load, it is necessary to take into account the displacement of the subsoil under the foundations. The subsoil is a material with typically non-linear behaviour. This paper presents an example of the modelling of a tall, 14-storey, building located in Lublin. The building was constructed on loess subsoil, with the use of a base slab. The subsoil lying directly beneath the foundations was described using the Modified Cam-Clay model, while the linear elastic perfectly plastic model with the Coulomb-Mohr failure criterion was used for the deeper subsoil. The parameters of the subsoil model were derived on the basis of the results of CPT soundings and laboratory oedometer tests. In numerical FEM analyses, the floors of the building were added in subsequent calculation steps, simulating the actual process of building construction. The results of the calculations involved the displacements taken in the subsequent calculation steps, which were compared with the displacements of 14 geodetic benchmarks placed in the slab.

1 December 2016 in Budownictwo i Architektura
Verified
Journal Article
Open access
PDF file
KNKrzysztof Nepelski
Krzysztof Nepelski
Agnieszka LalAgnieszka Lal
Agnieszka Lal
Małgorzata FranusMałgorzata Franus
Małgorzata Franus
W pracy przedstawiono porównanie wyników badań laboratoryjnych konsystencji gruntów lessowych Lublina z wynikami badań otrzymanych w wyniku sondowań statycznych CPT. Wyznaczone wartości stopni plastyczności porównano z wartościami oszacowanymi z sondowań na podstawie interpretacji z różnych źródeł bibliograficznych. Dodatkowo wyprowadzono własną formułę interpretacyjną. Stwierdzono, że dla podłoża lessowego jako kryterium wydzielenia geotechnicznego odpowiednie jest przyjęcie parametru wiodącego w postaci wartości qc, a nie IL, które najczęściej jest oznaczane dla gruntów spoistych. Przez wzgląd na możliwość uzyskania bardziej miarodajnych parametrów determinujących nośność podłoża istotne jest rozpoznanie zależności pomiędzy określonymi parametrami.

12 July 2018 in Scientific Review Engineering and Environmental Sciences (SREES)
Verified
Journal Article
Closed access
KNKrzysztof Nepelski
Krzysztof Nepelski
MRMałgorzata Rudko
Małgorzata Rudko
The paper presents an analysis of the results of tests carried out on loess subsoil in the Lublin region, classifi ed geotechnically according to PN-86/B-02480:1986 and PN-EN ISO 14688-1:2006 as silt, sandy silt and silty sands. In the field, over 300 CPT/CPTU with electric and mechanical cones tests were performed, testing a total of about 2,700 lm of the loess profile. In several places, comparative tests of the probing resistances obtained with different cones were carried out. In selected places, holes were drilled directly at the penetrometer tests and samples were taken for the laboratory tests. Moisture, consistency limits were determined in the laboratory. In addition, the strength parameters (angle of internal friction and cohesion) and deformation parameters (oedometer modules) were analyzed. The obtained results were also compared with the literature data and the results of tests carried out commercially for design purposes.