Agnieszka Lal

Mrs. Agnieszka Lal

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2022 in Materials
Verified
Journal Article
Open access
PDF file
Agnieszka LalAgnieszka Lal
Agnieszka Lal
Joanna FronczykJoanna Fronczyk
Joanna Fronczyk
Stabilization/solidification of contaminated soil is a process that allows simultaneous strengthening of the soil structure, disposal of contamination and recycling of industrial waste, implemented as substitutes for Portland cement or additives to improve the properties of the final product obtained. Extremely intensive development of studies pertaining to the S/S process prompted the authors to systematize the binders used and the corresponding methods of binding the contamination, and to perform an analysis of the effectiveness expressed in geomechanical properties and leachability. The study pays close attention to the types of additives and binders of waste origin, as well as the ecological and economic benefits of their use. The methods of preparing and caring for the specimens were reviewed, in addition to the methods of testing the effectiveness of the S/S process, including the influence of aging factors on long-term properties. The results of the analyses carried out are presented in the form of diagrams and charts, facilitating individual evaluation of the various solutions for the stabilization/solidification of soils contaminated with heavy metals.

6 June 2021 in Water
Verified
Journal Article
Open access
PDF file
PWPiotr Wichowski
Piotr Wichowski
MKMarek Kalenik
Marek Kalenik
Agnieszka LalAgnieszka Lal
Agnieszka Lal
DMDariusz Morawski
Dariusz Morawski
MCMarek Chalecki
Marek Chalecki
The paper presents results of investigations of influence of major head losses on exploitation properties of water supply pipes after 30-year exploitation. The tested materials were cast-iron pipes with the internal diameter of 150 mm. A flowability drop coefficient ηt with average value of 0.45 was determined. Using the measured values of pressure difference Δp determined the absolute roughness of internal walls of the pipes after 30-year exploitation, which was referred to the new pipelines. The absolute roughness for the exploited pipes was equal to k = 27.6 mm, whereas for the new ones it was significantly lower and equal to k = 0.9 mm. Additionally, an analysis of the chemical and mineral composition of sediments gathered in the investigated pipelines was also performed. The top layer of the sediments was dominated by the compounds of a character of the iron hydroxide: goethite (α-FeOOH) and lepidocrocite (γ-FeOOH), whereas the internal layer was supplemented by the gypsum and sulfur, which was proven by the investigations performed with the use of scanning electron microscope (SEM). The sediment gathered within the pipes is the main reason of ca. 30-fold increase of the absolute roughness, which resulted in the flowability drop of the exploited water supply pipes.

28 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KNKrzysztof Nepelski
Krzysztof Nepelski
Agnieszka LalAgnieszka Lal
Agnieszka Lal
Loess soils were created by the wind transporting particles with later or in parallel occurred protogenetic, syngenetic and epigenetic processes. As a result, various genetic processes affected loesses strength and deformability characteristics. The aim of the study is to estimate the main CPT parameters of loess subsoil in Lublin area according to divided facies. The subsoil in the area of the Nałęczowski Plateau, where Lublin is located, consists mainly of loess from aeolian and aeolian–diluvial facies, and in the deeper parts—from aeolian–alluvial facies. Most of the results obtained for the aeolian facies at the level of qc in the range from 4.5 to 8.0 MPa indicate that these soils are a good load-bearing substrate for building structures. Cone resistances mostly at the level of 1.5–4.0 MPa for the diluvial and alluvial facies confirm that these facies constitute less favorable foundation conditions. The reduced resistance results mainly from the increased water content in ground pores. It is especially the soils of the diluvial facies that provide unfavorable foundation conditions, as they occur near the surface. Genetic processes are a very important element that should be taken into account in engineering research.

3 December 2017 in Budownictwo i Architektura
Verified
Journal Article
Open access
PDF file
ŁBŁukasz Borowski
Łukasz Borowski
Agnieszka LalAgnieszka Lal
Agnieszka Lal
KNKrzysztof Nepelski
Krzysztof Nepelski
W niniejszej pracy zawarto rozważania dotyczące możliwych przyczyn nadmiernego osiadania znaków osnowy geodezyjnej. Do analiz wybrano znaki ziemne osnowy wysokościowej typu 75a i b. Przeprowadzono analizę obliczeniową osiadania znaków osnowy geodezyjnej, pracujących w różnych warunkach gruntowych oraz w dwóch złożonych obciążeniach. W celu uwzględnienia w obliczeniach najbliższych rzeczywistym warunków współpracy pomiędzy elementami osnowy geodezyjnej, a ośrodkiem gruntowym, modyfikowano przyjmowane parametry. Uzyskane wyniki porównywano z zaobserwowanymi w powiecie kętrzyńskim w trakcie transformacji układu wysokościowego z Kronsztadt’60 na Kronsztadt’86. Wynikiem prac jest określenie możliwych zmian osnowy wysokościowej, w okresie pomiędzy kampaniami pomiarowymi (około 20 lat).

1 December 2016 in Budownictwo i Architektura
Verified
Journal Article
Open access
PDF file
KNKrzysztof Nepelski
Krzysztof Nepelski
Agnieszka LalAgnieszka Lal
Agnieszka Lal
Małgorzata FranusMałgorzata Franus
Małgorzata Franus
W pracy przedstawiono porównanie wyników badań laboratoryjnych konsystencji gruntów lessowych Lublina z wynikami badań otrzymanych w wyniku sondowań statycznych CPT. Wyznaczone wartości stopni plastyczności porównano z wartościami oszacowanymi z sondowań na podstawie interpretacji z różnych źródeł bibliograficznych. Dodatkowo wyprowadzono własną formułę interpretacyjną. Stwierdzono, że dla podłoża lessowego jako kryterium wydzielenia geotechnicznego odpowiednie jest przyjęcie parametru wiodącego w postaci wartości qc, a nie IL, które najczęściej jest oznaczane dla gruntów spoistych. Przez wzgląd na możliwość uzyskania bardziej miarodajnych parametrów determinujących nośność podłoża istotne jest rozpoznanie zależności pomiędzy określonymi parametrami.

23 May 2019 in Budownictwo i Architektura
Verified
Journal Article
Open access
PDF file
Agnieszka LalAgnieszka Lal
Agnieszka Lal
Foundation of the buildings on the loessial soil is often associated only with difficulties resulting from the possibility of the collapse of the ground. For these reason, loess is too often unfairly disqualified as the construction subsoil in spite of its good strength and strain parameters. Thanks to continuous development of research and publications of the results, reliable data regarding loess are spread and, as a consequence, loess becomes more and more common soil used in the geotechnicalengineering.Loess collapsibility has been studied since the middle of the 20th century, nevertheless, only the computer techniques and specialist laboratory and microstructural tests, that have been developed from the end of last century, helped us to find an answer to the important questions regarding the occurrence of this phenomenon. Detailed mechanisms that cause sudden loess volumetric reduction due to humidity and load, and the elements that affects the collapsibility are still studied. Furthermore, varied technics are researched, including in-situ tests, which allow estimating the risk of collapse, as well as the methods of its elimination.The aim of this paper is to systematize the directions of current studies of European loess collapsibility and to indicate their most significant results. The review was made on the basis of the scientific publications published in the Polish and international journals as well as the Journal Citation Reports (JCR) Web of Science database.